User manual SAMSUNG SC-6540

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SAMSUNG SC-6540. We hope that this SAMSUNG SC-6540 user guide will be useful to you.

Lastmanuals help download the user guide SAMSUNG SC-6540.


Mode d'emploi SAMSUNG SC-6540
Download
Manual abstract: user guide SAMSUNG SC-6540

Detailed instructions for use are in the User's Guide.

[. . . ] Instead, they are requested to directly contact a designated service center or the outlet at which the product was purchased. x Never spill any kind of liquid into the unit. Should this happen, unplug or main switch off the unit and contact an authorized service center. x Do not insert anything between the air outlet blades because the inner fan may be damaged and could cause injury. [. . . ] Note (ON/OFF) button until all indicators Even if the air conditioner has been turned on via the ON/OFF button on the unit, operations can still be controlled using the remote control as usual. Selecting with the Remote Control To select the 5 Way function with the remote control, press the 5 Way button one or more times until the desired mode is selected. x Each time you press the 5 Way button: Each 5 Way indicator on the indoor unit lights up in order. E-9 Selecting the Automatic Operating Mode You can start the air conditioner in Automatic mode from your remote control. In the Automatic mode, the standard temperature and the optimum fan speed is selected automatically. You can adjust the standard temperature but not the fan speed. 1 If necessary, press the Result: (On/Off) button. x The 5 Way indicator on the indoor unit lights up. x The air conditioner starts up in the mode selected when the unit was last used. The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being: x Plugged in x Stopped lt will start up normally after three minutes. IMPORTANT 2 If the is not displayed at the top of the remote control, press the MODE button on the remote control one or more times until it appears. Result: x The indoor unit beeps each time you press the MODE button. x The air conditioner runs in AUTO mode. You can change modes at any time. Note 3 To adjust the standard temperature (The air conditioner automatically set the standard temperature by the current room temperature. ), press the TEMPERATURE buttons one or more times. -2C -1C < When you feel hot > < When you feel chilly > E-10 Cooling Your Room ENGLISH You must select the Cool mode if you wish to adjust the: x Cooling temperature x Fan speed when cooling 1 If necessary, press the Result: (On/Off) button. x The 5 Way indicator on the indoor unit lights up. Set to the initial position powered. Note Adjusting the Air Flow Direction Horizontally There are two sets of inner air flow blades. Just as the outer air flow blade can be adjusted vertically, the inner blades can be adjusted horizontally. 1 Adjust each set of inner blades to the required position, by pushing or pulling them sideways. E-15 Setting the On Timer The On Timer enables you to switch on the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. 1 To set the operating time, press the ON TIMER button one or more times until the required time is displayed. Possible time is between 0. 5 hour and 24 hour inclusive. 2 Press the Result: (Set/Cancel) button to complete the setting. x Blinking of the timer indicator stops. x The selected mode and the temperature on the display disappear after 10 seconds. x The air conditioner will switch on automatically when the counter displayed on the remote control reaches the set time and disappears the On timer setting. 3 To select an operating mode in advance, press the button until the desired mode is displayed at the top of the remote control. Result: x The air conditioner will run in the selected mode when it is turned on. To Cancel the On Timer 1 To cancel the On Timer, press the ON TIMER button one or more times until the timer setting disappears. 2 Press the (Set/Cancel) button. Note If you want to turn on the air conditioner before the timer reaches the setting time, press the (ON/OFF) button. E-16 Setting the Off Timer ENGLISH The Off Timer enables you to switch off the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. [. . . ] The automatic protection feature may be triggered and the air conditioner stopped. A water leak or some other malfunction may occur if the heat exchanger freezes. Water may condense on and drip from the surface of the indoor unit if it is used for long periods. Indoor Humidity 80% or less - Outdoor Temperature 21C to 43C approx. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SAMSUNG SC-6540

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SAMSUNG SC-6540 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag