[. . . ] OWNER'S INSTRUCTIONS
Indoor unit
SH05ZZ8 SH07ZZ8
Outdoor unit
SH05ZZ8X SH07ZZ8X
SPLIT TYPE ROOM AIR CONDITIONER
( Cool and Heat )
E R DB98-15865A(1)
Safety Precautions
The following safety precautions must be taken when using your air conditioner. · Disconnect all remote electric power supplies before servicing, installing or cleaning. · This must be done by the manufacturer or its service agent or a similar qualified person in order to avoid a hazard. Users of this product are cautioned not to attempt repair of this product at their own discretion. [. . . ] The air conditioner starts up in the mode selected when the unit was last used. The indoor unit beeps.
2
If the is not displayed at the top of the remote control, press the button on the remote control one or more times until it appears. Result: The indoor unit beeps each time you press the The air conditioner runs in FAN mode. button.
Note
3
Select the fan speed by pressing the until the required setting is displayed: Low Medium High Result: Each time you press the
button one or more times
button, the indoor unit beeps.
4
To control the direction of the air flow, refer to pages 16 and 17.
E-14
Selecting Energy Saving Mode
If you wish to save energy when using your air conditioner, select the Energy saving mode with the Energy saving button. 1 If necessary, press the Result: (On/Off) button.
The operation indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used. The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being: Plugged in Stopped lt will start up normally after three minutes.
IMPORTANT
2
Select COOL mode by pressing the Note
button.
You can select the Energy saving mode only in COOL mode.
3
Press the Result:
button. The air conditioner runs in the Energy saving mode. The outer air flow blade moves up and down. To stop the Energy saving mode, press the again.
4
To adjust the temperature, press the button one or more times until the required temperature is displayed. Possible temperatures are between 26°C and 30°C inclusive. Note If you want to adjust temperature under 26°C, cancel the Energy saving mode before adjusting the temperature.
5
To select the fan speed, press the the required setting is displayed.
button one or more times until
6
To control the direction of the air flow, refer to pages 16 and 17.
E-15
Adjusting the Air Flow Direction Vertically
Depending on the position of the indoor unit on the wall of your room, you can adjust the position of the outer air flow blade on the bottom of the unit, thus increasing the efficiency of the air conditioner. 1 Press the Result: button one or more times as required. Cooling Heating Adjust the blade to face. . . Downwards.
RECOMMENDATION
2
If you want the blade to move up and down automatically when the air conditioner is operating, press the button. Result: The blade moves up and down around the base position set.
3
To stop the blade moving up and down, press the
button again.
Note
If you switch the air conditioner. . . Set to the initial position powered.
E-16
Adjusting the Air Flow Direction Horizontally
There are two sets of inner air flow blades. Just as the outer air flow blade can be adjusted vertically, the inner blades can be adjusted horizontally. 1 Adjust each set of inner blades to the required position, by pushing or pulling them sideways.
E-17
Setting the On Timer
The On Timer enables you to switch on the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. 1 To set the operating time, press the button one or more times until the required time is displayed. Possible time is between 0. 5 hour and 24 hours inclusive.
2
Press the Result:
(Set/Cancel) button to complete the setting. [. . . ] Note Even if the air conditioner has been turned on via the On/Off button, operations can still be controlled using the remote control as usual.
E-23
Solving Common Problems
Before contacting the after-sales service, perform the following simple checks. They may save you the time and expense of an unnecessary call. Problem The air conditioner does not operate at all Explanation/Solution Check that the breaker used for the air conditioner is switched on. Check that the operation indicator on the indoor unit is on; if necessary press the (On/Off) button on the remote control. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SAMSUNG SH-05ZZ8
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.