Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SAMSUNG SH18ZP0D-XFO. We hope that this SAMSUNG SH18ZP0D-XFO user guide will be useful to you.
Lastmanuals help download the user guide SAMSUNG SH18ZP0D-XFO.
Detailed instructions for use are in the User's Guide.
[. . . ] OWNER'S INSTRUCTIONS
Indoor Unit
SH07APGD SH07ZP2D SH09APGD SH09ZP2D SH12APGD SH12ZP4D SH18AP0D SH18ZP0D SH24AP6D SH24ZP6D
Outdoor Unit
SH07APGDX SH07ZP2DX SH09APGDX SH09ZP2DX SH12APGDX SH12ZP4DX SH18AP0DX SH18ZP0DX SH24AP6DX SH24ZP6DX
Split-type Room Air Conditioner
(Cool and Heat)
E R DB98-21262A(1)
Register your product at www. samsung. com/global/register
Safety Precautions
The following safety precautions must be taken when using your air conditioner. · Disconnect all remote electric power supplies before servicing, installing or cleaning. · This must be done by the manufacturer or its service agent or a similar qualified person in order to avoid a hazard. x Users of this product are cautioned not to attempt repair of this product at their own discretion. [. . . ] The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being: x Plugged in x Stopped lt will start up normally after three minutes. button.
IMPORTANT
2
Select COOL mode by pressing the Note
You can select the Energy saving mode only in COOL mode.
3
Press the Result: x x x x
button. The air conditioner runs in the Energy saving mode. The outer air flow blade moves up and down. To stop the Energy saving mode, press the button again.
4
To adjust the temperature, press the button one or more times until the required temperature is displayed. Possible temperatures are between 26°C and 30°C inclusive. Note If you want to adjust temperature under 26°C, cancel the Energy saving mode before adjusting the temperature.
5
To select the fan speed, press the until the required setting is displayed.
button one or more times
6
To control the direction of the air flow, refer to page 17.
E-15
Generating Anions
The air conditioner can generate anions with an ionizer in the indoor unit. Since it is an additional function, you can select it any mode, even when the air conditioner is turned off. Note If you press the button during off, the air conditioner will turn on automatically and generate anions in the Fan mode with Low fan speed.
2
If you wish to stop the Anions function, press the button again. Result: The air conditioner is reset automatically to the previous mode, temperature and fan settings.
3
To control the direction of the air flow, refer to page 17.
E-16
Adjusting the Air Flow Direction Vertically
Depending on the position of the indoor unit on the wall of your room, you can adjust the position of the outer air flow blade on the bottom of the unit, thus increasing the efficiency of the air conditioner. 1 Press the Result: button one or more times as required. Cooling Heating Adjust the blade to face. . . Downwards.
RECOMMENDATION
2
If you want the blade to move up and down automatically when the air conditioner is operating, press the Result: button. The blade move up and down, around the base position set.
3
To stop the blade moving up and down, press the
button again.
Note
If you switch the air conditioner. . . Set to the initial position powered.
Adjusting the Air Flow Direction Horizontally
There are two sets of inner air flow blades. Just as the outer air flow blade can be adjusted vertically, the inner blades can be adjusted horizontally. 1 Adjust each set of inner blades to the required position, by pushing or pulling them sideways.
E-17
Setting the On Timer
The On Timer enables you to switch on the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. 1 To set the operating time, press the button one or more times until the required time is displayed. Possible time is between 0. 5 hour and 24 hour inclusive.
2
Press the Result:
(Set/Cancel) button to complete the setting. x Blinking of the timer indicator stops. x The selected mode and the temperature on the display disappear after 10 seconds. [. . . ] x Check whether the TIMER indicator on the indoor unit is switched on. If so: - Wait until the switch-on time is reached and the air conditioner starts up automatically - Cancel the timer (see pages 18 and 19 for further details) x Check that there are no obstacles between you and the indoor unit. x Check that you are close enough to the indoor unit (seven meters/yards or less). x Check that you are pointing the remote control at the remote control sensor in the right of the indoor unit. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SAMSUNG SH18ZP0D-XFO
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.