User manual SANGEAN CL-100 REV 1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SANGEAN CL-100. We hope that this SANGEAN CL-100 user guide will be useful to you.

Lastmanuals help download the user guide SANGEAN CL-100.


Mode d'emploi SANGEAN CL-100
Download
Manual abstract: user guide SANGEAN CL-100REV 1

Detailed instructions for use are in the User's Guide.

[. . . ] CL-100 GB Revision 1 Table of Contents Important Safety Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Introduction & How It Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Accessories & Main Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Location of Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] To program the radio with the FIPS code for your area, follow the steps below. Press the MENU button and press the TUNE DOWN to scroll down to the County Code, and press the SELECT button to enter the menu. Then All, Multiple and Single will be displayed. Choose Single if you want to receive only alerts sent to one county (or FIPS code). Choose Multiple if you want to receive alerts from more than one county that you have programmed. Choose All to receive all alerts your station sends regardless of the FIPS codes. Select Single to enter the Single County menu. Select New Code and enter a six digit sequence to set up the FIPS code. Use the TUNE UP/DOWN to select the desired number. Then use the VOL UP button to select the second digit. Repeat this sequence until you have set all six digits as desired, and press the SELECT button to save the code and exit to Single County menu. More than one set of FIPS codes can be stored under Single County mode, but only one set of code can work at a time. The codes that are stored will show in the Single County menu list. Press the TUNE UP/DOWN to highlight the stored code, and press SELECT button to overwrite an existing code. When a code is highlighted, press VOL UP/DOWN button to enable/disable the code. Under Multiple County mode, repeat the same instruction as above to set up, edit or enable / disable your FIPS codes. To leave the current operation, press the MENU button once. Note: If no code is enabled before leaving, the default County Code mode is All. GB 12 Setting up RBDS CT Radio Broadcast Data System, or RBDS, is a communications protocol standard for embedding small amounts of digital information in conventional FM radio broadcasts. The RBDS system standardizes several types of information transmitted, including time, station identification and program information. CT (Clock Time) is normally contained in the RBDS data, and you can set the date, weekday and time on a digital watch manually by the RBDS transmitted to your Sangean CL-100 following below instructions: Setting CT Manually 1. Tune to a station transmitting RBDS data, and press the CT button. The clock time of the radio will set up automatically according to the RBDS data received. [. . . ] Your radio has been factory programmed with the following alerts. *(UB)=Unblockable Code ------ ADR AVW BWW BZW CDW CFA CHW DBA DEW DSW EAT EVI FFA FFS FLA FLW FSW HMW HUA HWA IBW LAE LSW Message ------------------------------------------ Administrative message Avalanche Watch Boil Water Warning Blizzard Warning (UB) Civil Danger Warning Costal Flood Watch (UB) Chemical Hazard Warning Dam Watch (UB) Contagious Disease Warning Dust Storm Warning (UB) Emergency Action Termination (UB) Immediate Evacuation Flash Flood Watch Flash Flood Flood Watch Flood Warning Flash Freeze Warning (UB) Hazardous Mat. Warning Hurricane Watch High Wind Watch Iceberg Warning (UB) Local Area Emergency (UB) Land Slide Warning Code ------ AVA BHW CAE CEM CFW CWW DBW DMO EAN EQW EVA FCW FFW FLS FRW FZW HLS HUW HWW IFW LEW NIC NPT Message ------------------------------------------ Avalanche Watch (UB) Biological Hazard Warning Child Abduction Emergency (UB) Civil Emergency Message Coastal Flood Warning (UB) Contaminated Water Warning (UB) Dam Break Warning Practice / Demo (UB) Emergency Action Notification (UB) Earthquake Warning Evacuation Watch (UB) Food Contamination Warning Flash Flood Warning Flood Statement Fire Warning Freeze Warning Hurricane Statement (UB) Hurricane Warning High Wind Warning (UB) Industrial Fire Warning (UB) Law Enforcement Warning National Information Center National Periodic Test 28 GB Code ------ NAT NMN NST POS RHW SPS SVA SVS TOE TRA TSA TXB TXO VOW WSA **E **W 10D Message ------------------------------------------ National Audible Test Network Notification Message National Silent Test Power Outage Advisory (UB) Radiological Hazard Warning Special Weather Statement Severe Thunderstorm Watch Severe Weather StatementTOA 911 Telephone Outage Tropical Storm Watch (UB) Tsunami Watch Transmitter Backup On Transmitter Carrier Off (UB) Volcano Warning Winter Storm Watch Unrecognized Emergency (UB) Unrecognized Warning 10 Day Sentry Code ------ NUW RMT RWT SMW SPW SVR TOA TOR TRW TSW TXF TXP WFA **A **S *** WFW WSW Message ------------------------------------------ (UB) Nuclear Plant Warning Required Monthly Test Required Weekly Test Special Marine Warning (UB) Shelter In-Place Warning Severe Thunderstorm Warning Tornado Watch (UB) Tornado Warning (UB) Tropical Storm Warning (UB) Tsunami Warning Transmitter Carrier On Transmitter Primary On Wild Fire Watch Unrecognized Watch Unrecognized Statement Unrecognized Message (UB)Wild Fire Warning Winter Storm Warning 29 CL-100 Specifications WEATHER BAND CHANNELS Channel 1 2 3 4 5 6 7 Frequency (MHz) 162. 400 162. 425 162. 450 162. 475 162. 500 162. 525 162. 550 POWER REQUIREMENTS 6V DC 400mA (120V power adapter) 4AA Alkaline, Ni-Cad or NiMH Batteries (not included) WB Antenna: 21" Telescopic Rod Antenna Size: 18 (L) X 12 (W) X 4. 7 (D) cm GB 30 One Year Limited Warranty SANGEAN AMERICA, INC. , will repair or replace, at its option without charge, your CL-100 weather alert radio which fails due to a defect in material or workmanship within one year following the initial consumer purchase. This warranty does not include any antennas, which may be a part of or included with the warranted product, or the cost of labor for removal or re-installation of the product in a vehicle or other mounting. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SANGEAN CL-100

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SANGEAN CL-100 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag