User manual SANYO 12KHS71

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SANYO 12KHS71. We hope that this SANYO 12KHS71 user guide will be useful to you.

Lastmanuals help download the user guide SANYO 12KHS71.


Mode d'emploi SANYO 12KHS71
Download
Manual abstract: user guide SANYO 12KHS71

Detailed instructions for use are in the User's Guide.

[. . . ] 05-423 KHS0971-1271 12/13/05 1:23 PM Page a INSTALLATION INSTRUCTIONS ­ Inverter Split System Air Conditioner ­ COOL / DRY/ HEAT Model This air conditioner uses the new refrigerant R410A. Contents Page IMPORTANT!Please Read Before Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tools Required for Installation (not supplied) 1-2. [. . . ] 26a, 26b) while referring to the wiring diagram. (6) Be sure to secure the wiring with the provided clamp. NOTE When closing the air intake grille, press on both corners. 27) Please refer to "How to replace the grille" on page 8 for installing the air intake grille. Terminal plate Rear panel Plastic cover Wall Wiring 10" (25 cm) Fig. 26a Inter-unit wiring Earth plate Lock nut Top of conduit connector Fig. 26b 11 05-423 KHS0971-1271 12/13/05 1:23 PM Page 12 WARNING Loose wiring may cause the terminal to overheat or result in unit malfunction. Therefore, be sure all wiring is tightly connected. When connecting each power wire to the corresponding terminal, follow the instructions "How to connect wiring to the terminal" and fasten the wire securely tight with the fixing screw of the terminal plate. How to connect wiring to the terminal a) For Indoor Unit (1) Cut the wire end with a cutting pliers, then strip the insulation to expose the wire about 9/32" (7 mm). (2) Using a screwdriver, loosen the terminal screw on the terminal plate. (3) Insert the wire and tighten the terminal screw completely using a screwdriver. b) For Outdoor Unit s For solid core wiring (or F-cable) Strip 3/8" (10 mm) STRIP SIZE 9/32" (7 mm) (ACTUAL SIZE) Fig. 28 Strip 15/16" (25 mm) Solid wire Loop Insulation Fig. 29 Stranded wire Ring connector (1) Cut the wire end with a cutting pliers, then strip the insulation to expose the solid wire about 15/16" (25 mm). 29) (2) Using a screwdriver, remove the terminal screw(s) on the terminal plate. (3) Using the pliers, bend the solid wire to form a loop suitable for the terminal screw. (4) Shape the loop wire properly, place it on the terminal plate and fix it securely with the removed terminal screw using a screwdriver. s For stranded wiring (1) Cut the wire end with a cutting pliers, then strip the insulation to expose the stranded wiring about 3/8" (10 mm) and tightly twist the wire ends. 30 and 31) (2) Using a screwdriver, remove the terminal screw(s) on the terminal plate. (3) Using a ring connector fastener or pliers, securely clamp each stripped wire end with a ring connector. 30) (4) Place the ring connector wire, and replace and tighten the removed terminal screw using a screwdriver. 31 Screw Screw and special washer Ring connector Ring connector Wire Terminal plate Wire Fig. 32 12 05-423 KHS0971-1271 12/13/05 1:23 PM Page 13 3-9. [. . . ] (1) Connect the Lo side charging hose of the manifold valve to the service port on the wide tube service valve. 05-423 KHS0971-1271 12/13/05 1:23 PM Page 23 7. Remote Control Unit Installation Position The remote control unit can be operated from either a non-fixed position or a wall-mounted position. To ensure that the air conditioner operates correctly, do not install the remote control unit in the following places: q In direct sunlight q Behind a curtain or other place where it is covered q More than 26' (8 m) away from the air conditioner q In the path of the air conditioner's airstream q Where it may become extremely hot or cold q Where it may be subject to electrical or magnetic interference q Where there is an obstacle between the remote con- trol unit and the air conditioner (since a check signal is sent from the remote control unit every 5 minutes) 7-1. Mounting on a Wall Before mounting the remote control unit, press the ON/OFF operation button at the mounting location to make sure that the air conditioner operates from that location. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SANYO 12KHS71

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SANYO 12KHS71 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag