If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SANYO HIT DOUBLE 195. We hope that this SANYO HIT DOUBLE 195 user guide will be useful to you.
Lastmanuals help download the user guide SANYO HIT DOUBLE 195.
You may also download the following manuals related to this product:
SANYO HIT DOUBLE 195 DATASHEET 2 (578 ko)
SANYO HIT DOUBLE 195 INSTALLATION (242 ko)
Manual abstract: user guide SANYO HIT DOUBLE 195DATASHEET
Detailed instructions for use are in the User's Guide.
[. . . ] Bifacial Photovoltaic Module
Power per Square Foot up to 19. 1 Watts
Photo by Golden Energy, Santa Monica, CA
Phatport® - from Phat Energy, L. A. , CA
High Efficiency
HIT® Double bifacial solar panels are the World leaders in sunlight conversion efficiency, helping customers to enjoy the maximum power per square foot from available space.
Application Possibilities
· Architectural, Awnings, Balconies, Bus Shelters, BIPV · Deck & Porch Coverings, Canopies, Carports, Facades · Fences, Siding, Trellises, Tracking Systems
Power Guarantee
SANYO guarantees customers will receive 100% of the panel's rated power (or more) at the time of purchase, enabling owners to generate more kWh per rated watt.
Proprietary Technology
HIT bifacial solar cells are hybrids of single crystalline silicon surrounded by ultra-thin amorphous silicon layers, available solely from SANYO.
Bifacial Effect
The back face of HIT Double solar panels generates electricity from ambient light reflected off surrounding surfaces, and combines with power from the front face of the panel. Dependant upon system design and site albedo, this results in up to 30% higher power generation (more kWh) per square foot.
High Temperature Performance
As temperatures rise, HIT Double solar panels produce more electricity than conventional solar panels at the same temperature, for good performance in high temperature sites.
Quality Products
SANYO silicon wafers are made in California USA, and assembled in Mexico at SANYO's certified factory. [. . . ] Do not allow support rails to shade the panel's back face. Dependence on Temperature
195 W 55. 8 V 3. 5 A 68. 7 V 3. 73 A 600 V 15 A -0. 34% / °C -0. 192 V / °C 1. 70 mA / °C +10/-0% 19. 3%
Maximum Power Voltage (Vpm) Maximum Power Current (Ipm) Open Circuit Voltage (Voc) Short Circuit Current (Isc) Max. System Voltage (Vsys) Series Fuse Rating THPSHUDWXUH &RHI¿FLHQW 3PD[) THPSHUDWXUH &RHI¿FLHQW Voc) THPSHUDWXUH &RHI¿FLHQW , VF) Warranted Tolerance &HOO (I¿FLHQF\ 0RGXOH (I¿FLHQF\
2
4. 45 A 69. 5 V 4. 85 A
4. 00 3. 50 75°C 50°C 25°C
Current (A)
-- -- -- -- -- -- -- 20. 5% 19. 1 W
3. 00
2. 50 2. 00
0°C
1. 50
1. 00 0. 50
16. 1% 14. 9 W
Power per Square Foot
0. 00 0 10 20 30 40 50 60 70 80
MHFKDQiFDO SpeciÀFDWLRQV
Internal Bypass Diodes Module Area Module Weight Module Dimensions LxWxH Cable Lengths Cable Size / Connector Type Static Load Pallet Dimensions LxWxH Full Pallet Quantity & Weight Quantity per 20'/40'/53' Container 4 Bypass Diodes 13. 06 Ft2 (1. 21 m2) 50. 7 Lbs. (1351 x 898 x 60 mm)
3. 50 4. 50
Voltage (V)
Dependence on Irradiance
4. 00
1000 W/m2
39. 4 in. each (1000 mm)
Current (A)
800 W/m2 3. 00
No. 12 AWG / MC3TM Connectors 50 PSF (2400 Pa) 54. 3 x 36 x 70. 1 in. (460 kg) 200 pcs. , 420 pcs. , 540 pcs.
2. 50 2. 00
600 W/m2
1. 50
400 W/m2
6DIeWy 5DWLQJV & /LPLWHG :DUUDQWy
Fire Safety Classification Hail Safety Impact Velocity NOCT (°C) Safety & Rating Certifications Limited Warranties
1
1. 00 0. 50
200 W/m2
Class A 1" hailstone (25 mm) at 52 mph (23 m/s) 113°F (45°C) UL 1703, cUL, CEC 2 Years Workmanship / 20 Years Power Output
2
0. 00 0 10 20 30 40 50 60 70 80
Voltage (V)
IMPORTANT: The rated power of HIT® Double bifacial solar panels is measured under Standard Test Conditions (STC). STC does not account for power produced from the back face of panels. Therefore, HIT Double panels will produce more power than their STC rating, up to 30% more, depending upon the system design and site albedo. Account for the additional power when sizing, selecting system components and wiring.
Standard Test Conditions: Cell Temperature 25°C, Air Mass 1. 5, 1000 W/m 2 Equivalent module efficiency, including power from the back face. [. . . ] Winchester Blvd. , Suite 510 San Jose, CA 95128, U. S. A. www. sanyo. com/solar solar@sec. sanyo. com
© SANYO Energy (U. S. A. ) Corp. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SANYO HIT DOUBLE 195 Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SANYO HIT DOUBLE 195 will begin.