User manual SANYO HIT POWER 200N INSTALLATION

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SANYO HIT POWER 200N. We hope that this SANYO HIT POWER 200N user guide will be useful to you.

Lastmanuals help download the user guide SANYO HIT POWER 200N.


Mode d'emploi SANYO HIT POWER 200N
Download
Manual abstract: user guide SANYO HIT POWER 200NINSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] General Installation Manual © Apr 2010, Sanyo Electric Co. , Ltd. All Rights Reserved 4/22/10 General Installation Manual for SANYO · ® HIT Photovoltaic Modules. Please read this manual completely before installation or use of SANYO modules. This manual applies to the following · 125mm HIT Power products: HIT Power 215N (HIP-215NKHA5, NKHA6) HIT Power 210N (HIP-210NKHA5, NKHA6) HIT Power 205N (HIP-205NKHA5, NKHA6) HIT Power 200N (HIP-200NKHA5, NKHA6) · INTRODUCTION Thank you for choosing SANYO HIT photovoltaic (PV) modules. [. . . ] 2) Observe the requirements described in by a factor of 1. 25 when determining 3) The wind pressure load of the sections labeled INSTALLTION and voltage ratings, conductor capacities, installation site should be less than SPECIFICATIONS. 2 fuse sizes, and size of controls 2, 880N/m (60PSF). USA: 4) Some environmental conditions could INSTALLATION Refer to Section 690-7 and Section apply. Please refer to Sanyo's warranty General 690-8 of the U. S. Please read this guide completely before Code for an additional multiplying installation or use of the modules. This factor of 1. 25, which may be section contains electrical and mechanical applicable. specifications needed before using your SANYO PV modules. Installation (reference) · Modules should be firmly fixed in place in a manner suitable to withstand all expected loads, including wind and 38 mm snow loads. Solar Module · Metals used in locations that are 38 mm exposed to moisture shall not be Metal clamp B employed alone or in combinations that (2 places) could result in deterioration or corrosion. Metal clamp A · Install modules where they are not (2 places) shaded by obstacles like buildings and trees. Especially pay attention to avoid partially shading the modules by objects during the daytime. Mounting · Contact an Authorized Representative Structure Rail with questions regarding mounting Metal clamp A profiles for modules if needed. Metal clamp B Solar Module · Notes on Installation · Clearance between the roof surface and module frame is required to allow cooling air to circulate around the back Mounting Structure Rail M8 Bolt of the module. This also allows any Metal clamp B condensation or moisture to dissipate. M8 Bolt Install modules so that air can circulate Metal clamp A between the roof and the module. · Leave 1 inch of clearance between the Module roof and the module frame. If other M8 Nut M8 Nut Mounting Structure mounting means are employed this may effect the temperature of the panel. End of Module Between Modules · SANYO recommends the installation method and mounting profile shown in Figure 1 Installation Figure 1. SPECIFICATIONS · A module should be attached on a Notes on Specifications 3) The current output for the modules mount or support structure rail by metal 1) Rated electrical characteristics are shown in the SPECIFICATIONS clamps. The metal clamp must fulfill within ­5% to +10% of the values section is measured at Standard Test the following specifications. measured at Standard Test Conditions Conditions. These conditions may not Size:not less than 1. 5" (38 mm) width (STC). [. . . ] Method 2- Use a bolt and nut (see Figures 3. 1 and 3. 3) · If using this method, use one of the larger holes with diameter of 0. 205'` (5. 2 mm) The bolt and nut size should be No. 8 (0. 164'` diameter (4. 16 mm)), or No. 10 (0. 190'` diameter (4. 83 mm)) or M5 (0. 197'` diameter (5. 0 mm)). · Star washers must be used to make contact through the anodization of the module for this method. · In this case, the screw threads are not providing the electrical ground contact. Module Terminations · A junction box as a terminal enclosure is equipped for electrical connections. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SANYO HIT POWER 200N

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SANYO HIT POWER 200N will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag