User manual SANYO HIT POWER 205A INSTALLATION

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SANYO HIT POWER 205A. We hope that this SANYO HIT POWER 205A user guide will be useful to you.

Lastmanuals help download the user guide SANYO HIT POWER 205A.


Mode d'emploi SANYO HIT POWER 205A
Download
Manual abstract: user guide SANYO HIT POWER 205AINSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] General Installation Manual © Jul 2010, Sanyo Electric Co. , Ltd. 7/13/10 General Installation Manual for SANYO ® HIT Photovoltaic Modules. Please read this manual carefully before installing or · using SANYO modules. This manual applies to the following HIT Power products: HIT Power 220A (HIT-N220A01) HIT Power 215A (HIT-N215A01) HIT Power 210A (HIT-N210A01) HIT Power 205A (HIT-N205A01) · INTRODUCTION Thank you for choosing SANYO HIT photovoltaic (PV) modules. [. . . ] Install modules so that air can circulate between the roof and the module. · Leave 1 inch of clearance between the roof and the module frame. If other mounting means are employed this may effect the temperature of the panel. · SANYO recommends the installation method and mounting profile shown in Figure 1. · A module should be attached on a mount or support structure rail by metal clamps. The metal clamp must fulfill the following specifications. Mounting Structure Rail Metal clamp A Size: not less than 1. 5" (38 mm) width Thickness: not less than 0. 12"(3 mm) Material: aluminum alloy bolt torque range: 16N. m to 20N. m. Operating Conditions SANYO requires that modules be operated within the following Operating Conditions: 1) Terrestrial applications only--no outer space or Special Conditions (see below). 2) 2) The ambient temperature must be within ­20°C (-4°F) to 46°C (115°F). The temperature limits are defined as the Monthly Average High or Low of the installation site. 3) The wind pressure load of the installation site should be less than 2 2, 880N/m (60PSF). 4) Some environmental conditions could apply. Please refer to Sanyo's warranty exclusions. measured at Standard Test Conditions (STC). STC conditions are; Irradiance o of 1000W/m, 25 C cell temperature, and solar spectral irradiance per IEC 60904-3. Note: At the time of shipment, Sanyo guarantees the output level of its modules to be -0/+10% against Rated Power in SPECIFICATIONS based on Sanyo's factory inspection at STC conditions. Under real conditions, a photovoltaic module may experience conditions that produce more current and/or voltage than reported at Standard Test Conditions. Therefore, Isc value of modules should be multiplied by a factor of 1. 25 to determine ampacity. An additional factor of 1. 25 may be required for sizing conductors, fuses, disconnects, etc. Please refer to section 690. 8 of the National Electrical Code (NEC) for guidelines. The Voc must be factored according to the lowest recorded ambient temperature recorded for the location where the modules will be installed. Please refer to section 690. 7 of the NEC for more information regarding voltage Solar Module Metal clamp B Solar Module Mounting Structure Rail M8 Bolt Metal clamp B Metal clamp A Module M8 Nut Mounting Structure End of Module M8 Nut M8 Bolt Between Modules Figure 1. Installation 2 General Installation Manual © Jul 2010, Sanyo Electric Co. , Ltd. [. . . ] Conduit · In applications where wire raceways or conduit are used, follow the applicable codes for outdoor installations. · Verify that all fittings are properly installed to protect wires against damage and prevent moisture intrusion. DIODES Bypass Diodes · When modules in series strings are partially shaded, it may cause reverse voltage across cells or modules, because the current from other cells in the same series is forced to flow through the shaded area. This may cause undesirable heating to occur. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SANYO HIT POWER 205A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SANYO HIT POWER 205A will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag