[. . . ] Direct Heat & Air JacketTM CO2 Incubator
SANYO laboratory CO2 incubators are designed for a wide range of applications in biomedical, pharmaceutical and clinical laboratories.
inCu saFe Interior
MCO-17AC MCO-34AC
control panel
SANYO is known for innovative and exclusive contamination control features such as inCu saFeTM, a copper enriched stainless steel alloy with inherent germicidal protection against contaminants. [. . . ] All are easily removed for cleaning.
Anti Contamination Design Benefits
Control, Alarm and Monitoring
A range of setpoint, alarm and programmable inputs are established through the use of an intuitive keypad. Extra large digital displays are easy to read. · Tactile feedback, touch pad and entry keys simplify operation · Standard parameters are factory-set for quick start-up, and all parameters can be changed as required. · A remote alarm terminal mounted at the rear of the cabinet can be connected to an external remote alarm system.
*Direct Heat and Air JacketTM U. S. Patent5519188; **inCu saFe Direct Heat and Air JacketTM, P. I. D. /RTM and Active Background Contamination ControlTM are trademarks of SANYO Electric Biomedical Co. , Ltd.
My life. My choice.
Incubation
www. sanyobiomedical. com
Specifications
Model Exterior dimensions (W x D x H) Interior dimensions (W x D x H) Effective capacity Net weight Shelves Exterior finish Interior finish Door Inner door Insulation Air circulation system Heating method Temperature Control Temperature range Temperature uniformity Chamber humidity Humidifying system CO2 control CO2 range CO2 variation CO2 inlet pressure Power source Power consumption Alarm system
CO2
Humidity
Incubation
MCO-17AC/MCO-34AC (2 x MCO-17AC + stacking kit) 24. 4" x 24. 0" x 35. 4" (619. 7 x 609. 6 x 899. 2mm) 19. 2" x 19. 8" x 26. 2" (487. 7 x 502. 9 x 665. 5mm) 5. 8 cu. ft. 7 Baked-on acrylic finish on galvanized stainless steel Copper alloy stainless steel Baked-on acrylic finish on galvanzied steel with door heater Tempered glass Foam in place polyurethane (non CFC) Gentle air circulation, upward air flow Direct Heat & Air (DHA) jacket system Microprocessor P. I. D. control Ambient temperature +5ºC ~ 50ºC ± 0. 2°C (setting temperature: 37°C, ambient temperature: 20°C) 95% ± 5% RH (at: 20°C, 60% RH) Natural evaporation with water in humidity pan Microprocessor control (sensor: Thermal Conductivity) 0 - 20% ± 0. 15% 5 - 7 psi Voltage: 115V, 60hz, Amps: 3. 6A, Plug/Breaker: NEMA 5-15P/15A 405W · Audible and visual alarm · Temperature, CO2, Door alarm · Independent overheat protection circuit sensor · Remote alarm contacts
Optional Accessories:
· Rollerbase, MCO-18RB · CO2 Regulator, MCO-100L · Stacking Kit, MCO-18PS
(required to create MCO-34AC)
Temperature
GREEN product
SANYO is committed to developing green technologies that provide energy efficiency resulting in lower operational costs with less impact on the environment.
Temperature Uniformity
Temperature Uniformity
Temperature Uniformity Measurement position 1
2
2
3 0. 00 . 4 0. 00
-0. 15
4
5 -0. 15 +0. 05
5 +0. 05
Shelf position
Measurement position Upper shelf 1 +0. 03 +0. 03
+0. 14 3
0. 00 .
Middle shelf
Upper shelf
Shelf position
+0. 14
Lower shelf Middle shelf
Lower shelf
-0. 15
-0. 15
-0. 13 0. 00 -0. 18
-0. 13 -0. 18 -0. 13
-0. 13
+0. 05
+0. 05
Condition: Set temperature 37° C, Ambient temp. [. . . ] 1- 300 Applewood Crescent, Concord, Ontario L4K 5C7 905-760-4025 · Fax 905-760-9945
LR-MCO17AC-07 . 08 [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SANYO MCO-34AC
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.