[. . . ] these portable autoclaves are designed for individual lab use and can conveniently be moved from one lab to another. model mls-3751l has a low enough profile to be stored under a lab bench when not in use. 38. 0 inches 18. 8 inc 29. 4 inches sterilization hes 18. 8 inches Sterilization Temperatures +115°C to +135°C innovation performance reliability support innovation performance reliability support s t e r i l i z a t i o n RELIABILITY & CONTROL Optional Process Printer (Model MLS-37PR) process documentation is available via an optional built-in type thermal printer. the printer prints out the process run results of temperature, pressure, vs. [. . . ] each step of the process is notified via a pre-recorded voice message, allowing the end user to hear the process as it is happening from across the room. Integrated Cool Down Fan Included as a standard feature, the cooldown fan decreases cool down process times significantly. this enables access to sterilized contents much faster. Air Vent Control the exhaust valve release temperature can be set to allow automatic release after the sterilizing cycle has been completed. the setting range is from +0°c to 45°c above boiling point to suit the items being sterilized (patent pending). Optional Object Temperature Sensor (Model MLS-37SB) measures temperature of items in the autoclave chamber and sets the sterilization timer accordingly. suitable for materials that heat up more slowly than the chamber, such as resins. after installation, the autoclave control system can be switched between this sensor and the main sensors. Double Interlocking Structure to ensure the safe operation of this high temperature, high-pressure autoclave, the chamber and the open/close hand-pull lever are controlled by a double interlock system dependent on temperature and pressure sensors. this way, it is impossible to open the autoclave until temperature and pressure levels are safe. CONTROL PANEL s PROCESS OPERATION t e r i l i z a t i o n PRE-SET PROGRAMS these units offer a total of 12 pre-set programs to choose from on a simpleto-operate control panel with lighted temperature/timer indicators. they also allow for independent programming for users to set their own programs. Sterilizing For water, culture media, reagents and other fluids. after completion and cooling to a selected temp. , air is expelled automatically through the exhaust valve. sterilizing temp. : 115°c to 135°c timer: 1 minute to 5 hours exhaust temp. : 0°c to 45°c. Sterilizing/Keep Warm after sterilizing culture media, reagents and other liquids, and cooling down naturally to a selected temp. , air is expelled automatically from the exhaust valve. sterilizing temp. : 115°c to 135°c timer: 1 minute to 5 hours exhaust temp. : 0°c to 45°c Warming temp. : 45°c to 60°c. Melting/Keep Warm to melt or keep culture media at a fixed temp. (this function is not for sterilizing but prevents solidifying. ) melting temp. : 60°c to 114°c timer: 72 hours Warming temp. : 45°c to 60°c Instrument Sterilizing For flasks, beakers, test tubes, and other lab instruments. [. . . ] Effective capacity External dimensions Chamber dimensions Effective chamber height Power specifications Unit weight Wire baskets included Printer Controller Voice alert process guidance system Sterilization temperature Culture media melting temperature Keep warm temperature Cool down fan Sterilization timer Melting timer Keep warm timer Program timer Exhaust control Safety devices Chamber material Maximum pressure Pressure gauge Accessories included Optional accessories Melting timer Keep warm timer Program timer Exhaust control Safety devices Chamber material Maximum pressure Pressure gauge 1 minute up to 5 hours 72 hours delayed, auto off 1 week (designation: year, month, day, hour and minute) Exhaust valve open temperature setting Pressure safety valve, over-temperature limiter, anti-scorch limiter, door interlock, over-pressure limiter, current fuse SUS 304 stainless steel 34. 14 PSI (0. 235 MPa) Upper right, front panel 29. 4 MLS-3751L MLS-3781L 50 liters (1. 8 cu. ft. ) 75 liters (2. 6 cu. ft. ) 29. 4 18. 8"W x 24. 9"D x 30. 7"H (478 mm W x 632 mm D x 748 mm H) 18. 8"W x 24. 9"D x 38. 0"H (478 mm W x 632 mm D x 965 mm H) 14. 6" (370 mm) diameter x 16. 3" (415 mm) depth 14. 6" (370 mm) diameter x 24. 2" (640 mm) depth 18. 9" (480 mm), including recess in lid 27. 8" (705 mm), including recess in lid 30 6-30 120V, 60Hz, 1 phase, 20 Amp breaker, NEMA L5-20P locking plug 208V-230V, 60Hz, 1 phase, 20 Amp breaker, NEMA L5-20P locking plug 134 lbs. (70 kg) 2 x stainless steel baskets, MLS-37BL x 1, MLS-37BS x 1 3 x stainless steel baskets, MLS-37BL x 2, MLS-37BS x 1 Optional, built-in type thermal printer, pressure and temperature vs. time process printout, MLS-37PR Microprocessor controller with process indicators, 12 pre-set programs, LED digital display, location on lid Standard, automated voice process guidance, on/off function o o 115 C to 135 C o o 60 C to 114 C o o 45 C to 60 C Standard, built-in 1 minute up to 5 hours 1 minute up to 5 hours 72 hours delayed, auto off 1 week (designation: year, month, day, hour and minute) Exhaust valve open temperature setting Pressure safety valve, over-temperature limiter, anti-scorch limiter, door interlock, over-pressure limiter, current fuse SUS 304 stainless steel 34. 14 PSI (0. 235 MPa) Upper right, front panel Drain Hose: (1), Exhaust tank (1), exhaust hose at rear side (1), tank mounting bracket (1) Object Sensor model MLS-37SB, Process Printer model MLS-37PR Dimensions MLS-3751L MLS-3781L sterilization Accessory Stainless Steel Buckets and Baskets MLS-37BL large stainless steel mesh basket Diameter - 13. 2" Height - 8. 7" mls-3751l : 1 will fit mls-3781l: 2 will fit MLS-37BS small stainless steel mesh basket Diameter - 13. 2" Height - 6. 7" mls-3751l : 1 will fit mls-3781l: 1 will fit MLS-37C30 solid bucket Diameter - 13. 0" Height - 11. 8" mls-3751l : 1 will fit mls-3781l: 2 will fit MLS-37PB30 MLS-37PB40 stainless steel bucket stainless steel bucket perforated Holes for 3 liter flasks perforated Holes for 3 liter flasks Diameter - 13. 0" Diameter - 13. 2" Height - 11. 8" Height - 15. 7" mls-3751l : 1 will fit mls-3781l: 2 will fit mls-3751l : 0 will fit mls-3781l: 1 will fit w w w. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SANYO MLS-3751L

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SANYO MLS-3751L will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag