User manual SANYO MVP-85

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SANYO MVP-85. We hope that this SANYO MVP-85 user guide will be useful to you.

Lastmanuals help download the user guide SANYO MVP-85.


Mode d'emploi SANYO MVP-85
Download
Manual abstract: user guide SANYO MVP-85

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTION MANUAL MVP-85 Quad Compressor Compresseur quadruplex Compresor cuádruple English GB Français F Español E About this manual · Before installing and using this unit, please read this manual carefully. Be sure to keep it handy for later reference. Acerca de este manual · Antes de instalar y usar este aparato, lea detenidamente este manual. Asegúrese de guardarlo a mano para futuras referencias. À propos de ce manuel · Avant d'installer et d'utiliser cet appareil, veuillez lire ce manuel attentivement. Assurez-vous de le garder à portée de la main pour référence ultérieure. PRECAUTION CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN Declaration of Conformity MVP-85 SANYO SANYO FISHER COMPANY 21605 Plummer Street, Chatsworth, California 91311 Telephone No. [. . . ] Example: To set the title "GATE-1F" for the camera 1 and "HALL-2F" for camera 2. 1 Press the + (or ­) button to set the first character "G", then press the c button. By pressing the + (or ­) button repeatedly, the characters are selected as follows: · Letters: A, B, C, . . . . X, Y, Z · Numbers: 0, 1, . . . . 8, 9 · Symbols: ­ : . / * _ 2 Following the same procedure, enter the rest of the title "ATE-1F". 3 Press the l button to set the cursor at the first character location for camera 2. Press the + (or ­) button to set first character "H", then press the c button. 4 Following the same procedure, enter the rest of the title "ALL-2F". 2-1 (TITLE SET) 1 2 3 4 5 6 7 8 TITLE G--------1 ---------2 ---------3 ---------4 ---------5 ---------6 ---------7 ---------8 QUAD VCR 2-2 (TITLE SET) 1 2 3 4 5 6 7 8 TITLE GATE-1F--1 ---------2 ---------3 ---------4 ---------5 ---------6 ---------7 ---------8 QUAD VCR 2-3 (TITLE SET) 1 2 3 4 5 6 7 8 TITLE GATE-1F--1 H--------2 ---------3 ---------4 ---------5 ---------6 ---------7 ---------8 QUAD VCR 2-4 (TITLE SET) 1 2 3 4 5 6 7 8 TITLE GATE-1F--1 HALL-2F--2 ---------3 ---------4 ---------5 ---------6 ---------7 ---------8 QUAD VCR 3 Press the MENU button to go to the next menu screen, or Press the EXIT button to exit the menu display. LIVE NOTE: To set the display mode for the title, refer to "DISPLAY SET (CLOCK, TITLE)" on page 22. 18 English ALARM SETTING (ALARM SET) Changing the Settings VIDEO OUT (A) (ALARM SET) BUZZER ON DURATION 10 S RETRIGGER ON DATA ON VIDEO OUT FULL DOUBLE ALARM SWITCH Menu 4 When an alarm trigger is received from sensors such as a door bell, movement sensor, etc. you can set the display mode and the recording mode for the pictures from the concerned camera. 1 2 3 4 Press the MENU button 4 times to display the (ALARM SET) menu. Press the l button to highlight the setting to modify. Using the + (or ­) button, select the desired setting, then press the l button. · Repeat step 3, until all the settings are as desired. (ALARM SET) BUZZER ON DURATION 10 S RETRIGGER ON DATA ON VIDEO OUT NC Press the MENU button to go to the next menu screen, or (ALARM SET) BUZZER ON DURATION 10 S RETRIGGER ON DATA ON VIDEO OUT QUAD STILL OFF ZOOM OFF Press the EXIT button to exit the menu display. 1, 2 (ALARM SET) BUZZER ON DURATION 10 S RETRIGGER OFF DATA ON VIDEO OUT FULL DOUBLE ALARM SWITCH 3 (ALARM SET) BUZZER ON DURATION 10 S RETRIGGER OFF DATA ON VIDEO OUT FULL DOUBLE ALARM SWITCH FULL: If an alarm trigger is received while in quad screen, the picture from the camera corresponding to the alarm input will be displayed full screen. (Default setting) DOUBLE ALARM This item is only displayed and can only be set if "VIDEO OUT" above is set to "FULL". SWITCH: The picture from each concerned camera will be displayed sequentially at 1 second interval. (Default setting) FIRST: The picture from the first alarm received only is displayed. LAST: The picture from the last alarm received is displayed. LIVE QUAD LIVE ALARM SET menu BUZZER ON: A buzzer will be heard when an alarm trigger is received. (Default setting) OFF: The buzzer will not be heard. VIDEO OUT (B) QUAD: If an alarm trigger is received while in full screen, the display mode will switch to quad screen. STILL The image from the camera corresponding to the alarm trigger will be frozen. (Default setting) ON: DURATION The alarm duration can be set to: 1, 2, 3, 4, 5, 10 (Default setting), 30 seconds, CC, NC CC: The alarm will go on for as long as the alarm signal is received (minimum 1 second). NC: The alarm will continue until canceled. ZOOM ON: The image from the camera corresponding to the alarm trigger will be zoomed in. (Default setting) RETRIGGER To set if an alarm is received while the unit is already in alarm mode. OFF: The unit will not receive another alarm, while one is already being received. (Default setting) ON: During alarm mode, other alarm triggers will be received and the alarm duration will be extended. VIDEO OUT (C) NC: The display mode will remain unchanged when an alarm trigger is received. DATA The camera number, date, time, type of the alarm can be recorded. (To view the recorded alarm data, refer to "ALARM DATA DISPLAY" on page 26. ) ON: The alarm data is recorded. [. . . ] (Refer to "COMMAND TABLE 4" on page 31. ) 28 English RS232C CONTROL INFORMATION GATHERING COMMANDS STATUS SENSE(D7) When this command is sent from the computer, this unit will send a 5-byte response (see Table 1). ALARM STATUS SENSE(D5) The external, video loss and video sensor alarm states are indicated by a 6-byte response (see Table 2). RXD TXD D7 d1 d2 d3 d4 d5 RXD TXD D5 d1 d2 d3 d4 d5 d6 STATUS SENSE(D7) byte assignment (Table 1) The third, fourth and fifth bytes are reserved. First byte Bit 7 LIVE/VCR indication 6 5 4 3 2 1 0 3-bit indication of the display mode 4-bit indication of the channels and quad screen displayed Bit state information 0: LIVE picture mode 1: VCR playback mode 000: Full screen 001: Quad screen 010: Menu display (Full screen mode) 0000: Channel 1 0001: Channel 2 0010: Channel 3 0011: Channel 4 0100: Channel 5 0101: Channel 6 0110: Channel 7 0111: Channel 8 (Quad screen) 0000: Quad screen A (1, 2, 3, 4) 0001: Quad screen B (5, 6, 7, 8) (Menu display) 0000: Menu 1 (LANGUAGE/LANG. /IDIO. ) 0001: Menu 2 (CLOCK SET) 0010: Menu 3 (TITLE SET) 0011: Menu 4 (ALARM SET) 0100: Menu 5 (VIDEO SENSOR SET) 0101: Menu 6 (TIMER SET) 0110: Menu 7 (DISPLAY SET) 0111: Menu 8 (VCR SET) 1111: Menu 9 (ALARM DATA) ALARM STATUS SENSE(D5) byte assignment (Table 2) First byte Bit 7 6 5 4 3 2 1 0 ALARM ON 8 ALARM ON 7 ALARM ON 6 ALARM ON 5 ALARM ON 4 ALARM ON 3 ALARM ON 2 ALARM ON 1 Second byte Bit 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 Third byte Bit 7 6 5 4 3 2 1 0 SENSOR 8 SENSOR 7 SENSOR 6 SENSOR 5 SENSOR 4 SENSOR 3 SENSOR 2 SENSOR 1 Fourth byte Bit 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 Fifth byte Bit 7 6 5 4 3 2 1 0 VIDEO LOSS 8 VIDEO LOSS 7 VIDEO LOSS 6 VIDEO LOSS 5 VIDEO LOSS 4 VIDEO LOSS 3 VIDEO LOSS 2 VIDEO LOSS 1 Sixth byte Bit 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 Second byte Bit 7 EXT/ALARM indication 6 VIDEO LOSS indication 5 SENSOR indication 4 Reserved 3 4-bit indication of the 2 display mode 1 0 Bit state information EXTERNAL ALARM is ON VIDEO LOSS is ON SENSOR is ON 0 0000: Normal display mode 0001: Sequential display mode 0010: Zoomed in mode 0011: Still image mode 0100: Frozen zoomed in image 0101: Zoomed in still image 0110: Zoom range setting mode 0111: Zoomed in still image range setting mode English 29 RS232C CONTROL COMMANDS AVAILABLE FROM THE QUAD COMPRESSOR ACK(0A) Response when this unit receives a command. NAK(0B) Response if this unit did not receive the command. ALARM(BF) When there is an alarm, this command is sent as header. Then, the alarm information is sent in a 1-byte transmission (see Table 3). ALARM information (Table 3) Bit 7 2-bit indication of the 6 alarm type 5 4 3 2 1 0 Reserved Reserved 4-bit indication of the camera number Bit state information 01: External alarms 10: Video loss alarms 11: Sensor alarms 0 0 0111: CAMERA NO. 1 OTHER COMMANDS ENTER(40) When numeric commands are all sent, this command is used to enter the transmitted value. CLEAR(56) To erase multiple byte commands. 30 English RS232C CONTROL COMMAND TABLE (TABLE 4) The commands available are indicated in the table. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SANYO MVP-85

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SANYO MVP-85 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag