If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SAUNIER DUVAL ENVIROPLUS F24E. We hope that this SAUNIER DUVAL ENVIROPLUS F24E user guide will be useful to you.
Lastmanuals help download the user guide SAUNIER DUVAL ENVIROPLUS F24E.
Manual abstract: user guide SAUNIER DUVAL ENVIROPLUS F24E04-04
Detailed instructions for use are in the User's Guide.
[. . . ] 2000225294A. 04. 04
Instructions for Use Installation and Servicing
To b e l e f t w i t h t h e u s e r
G. C. 47-920-45 HIGH EFFICIENCY CONDENSING COMBINATION BOILER
G. C. 47-920-39 HIGH EFFICIENCY CONDENSING COMBINATION BOILER
F28e
F28e SB
G. C. 41-920-37 HIGH EFFICIENCY CONDENSING SYSTEM BOILER
Saunier Duval, Nottingham Road, Belper, Derbyshire. [. . . ] (The flue assembly is an entirely push fit design), see diagram 8. 8. Terminal Installation, see diagram 8. 9.
2000225294A
26
8 Vertical Flue Preparation and Fitting
12192
FITTING FLAT ROOF FLASHING FITTING PITCHED ROOF FLASHING VERTICAL ROOF TERMINAL 565 100
TERMINAL
*
1x90° or 2x45° ELBOWS 1 METRE EXTENSION 730
FLAT ROOF FLASHING
* *
1 METRE EXTENSION PITCHED ROOF FLASHING Fit flat roof or pitched weather collar onto vertical roof terminal. Make sure a weather proof seal is made in accordance with good building practice. VERTICAL ROOF TERMINAL
*
1 METRE EXTENSION 1x90° or 2x45° ELBOWS
400-500mm ADJUSTABLE PIPE VERTICAL FLUE ADAPTOR
445
140 1195
* FIXING BRACKETS
1 METRE EXTENSION
Diagram 8. 8
Diagram 8. 9
27
2000225294A
12196
8 Twin Flue Preparation and Fitting
TWIN FLUE ADAPTOR KIT Pt. No. A2025000 TWIN PIPE TO CONCENTRIC ADAPTOR Pt. No. 08511800 PITCHED ROOF WEATHER COLLAR Pt. No. 08510500 1M EXTENSION Pt. No. 08547800 (Aluminium)
12209
0. 5M EXTENSION Pt. No. 08547600 (Aluminium)
FLAT ROOF WEATHER COLLAR Pt. No. 08510700 SINGLE PIPE TO TERMINAL ADAPTOR Pt. No. 08511900
0. 5M EXTENSION AIR DUCT Pt. No. 08547200 (Plastic)
45° BEND Pt. No. 08538800
HORIZONTAL FLUE TERMINALS Pt. No. 08511500
FIXING BRACKET VERTICAL Pt. No. 08512000
FIXING BRACKET TWIN FLUE Pt. No. 08511700
CONCENTRIC HORIZONTAL TERMINAL Pt. No. 08584900 90° BEND Pt. No. 08538700 Diagram 8. 10
8. 10 Twin Flue
These instructions are for the installation of this twin flue and its accessories only. Diagram 8. 10 shows the Twin Flue Adaptor kit and Accessories. Refer to the Flue Options Guide available from your nearest stockist for flue lengths and sample installations. Lubricate the rubber seals prior to inserting flue pipes. Make sure all joints are properly fitted, sealed and secured. If an extension pipe requires cutting, cut the plain end not the flared end where the sealing rings are fitted. Your selected flue arrangement must be secured with fixing brackets. One fixing bracket to be used for every metre of flue pipe used. The terminal should be positioned as to cause the least problem with the dispersal of products of combustion and any pluming that may occur. The use of weather collars are the preferred method when installing the roof terminal.
2000225294A
28
8 Twin Flue Preparation and Fitting
FLUE CONFIGURATION EXAMPLE INCLUDING DIMENSIONS TO AID CUTTING AND INSTALLATION AIR DUCT 45°ELBOW TERMINAL 50 50
12198
50 900 92 92 40 50 1 METRE EXTENSION 90°ELBOW 1 METRE EXTENSION
1000
FLUE DUCT TERMINAL
1 METRE EXTENSION TWIN FLUE ADAPTOR
Diagram 8. 11
TWIN FLUE ADAPTOR
12199
An Example Twin Flue Installation. (The flue assembly is an entirely push fit design), see diagram 8. 11. Fitting Twin Flue Adaptor, see diagram 8. 12. Fitting Twin Flue Terminals, see diagram 8. 13. Fitting Concentric Horizontal Terminal, see diagram 8. 14. Fitting Vertical Roof Terminal, see diagram 8. 15. Fitting Weather Collars, see diagram 8. 16.
SUPPORT BRACKET
Diagram 8. 12
29
2000225294A
8 Twin Flue Preparation and Fitting
90°ELBOW
12203 11742
SEALING COLLARS 1 METRE EXTENSION (cut to fit) 90°ELBOW AIR DUCT TERMINAL
SEALING COLLARS
FLUE DUCT TERMINAL Diagram 8. 13
1 METRE EXTENSION
CONCENTRIC ADAPTOR
INTERNAL SEALING COLLAR
CONCENTRIC HORIZONTAL TERMINAL
EXTERNAL SEALING COLLAR Diagram 8. 14
2000225294A
30
8 Twin Flue Preparation and Fitting
11743
FLAT ROOF FLASHING
VERTICAL ROOF TERMINAL 565
100
VERTICAL ROOF TERMINAL
730
After installation the vertical roof terminal must be secured with a fixing bracket
SINGLE CONCENTRIC PIPE ADAPTOR ADAPTOR
Fit flat roof or pitched weather collar onto vertical roof terminal. Make sure a weather proof seal is made in accordance with good building practice. PITCHED ROOF FLASHING
SINGLE PIPE ADAPTOR
445 CONCENTRIC ADAPTOR
VERTICAL ROOF TERMINAL 1195
1 METRE EXTENSION CONCENTRIC ADAPTOR
140
SINGLE PIPE ADAPTOR Diagram 8. 15 Diagram 8. 16
31
2000225294A
12204
9 Gas/Water Connections These packs are for the (F24e & F28e ONLY)
Packs supplied with the boiler
1. Isolating valve pack containing Heating isolating valves (2 off) Domestic cold water isolating valves (1 off) Domestic hot water elbow (1 off) Gas isolating valve (1 off) 2. [. . . ] Remove the central heating flow thermistor, see section 16. 14. Remove the igniter unit, see section 16. 3. Remove the transformer, see section 16. 5. Remove the burner and fan, see section 13. 3. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SAUNIER DUVAL ENVIROPLUS F24E
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.