If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SAUNIER DUVAL THELIA 23. We hope that this SAUNIER DUVAL THELIA 23 user guide will be useful to you.
Lastmanuals help download the user guide SAUNIER DUVAL THELIA 23.
Manual abstract: user guide SAUNIER DUVAL THELIA 23
Detailed instructions for use are in the User's Guide.
[. . . ] THELIA
THIS IS A CAT II2H3+ APPLIANCE
IN WARRANTY TECHNICAL HELPLINE
01773 828400
01773 828100
1
INSTALLATION AND OPERATING INSTRUCTIONS
THELIA 23, THELIA 23 E, THELIA SB 23
Note!The boiler serial number is marked on the label attached to the inside of the door. Refer to the "Introduction" section page 3 for a description of the basic functions of the boiler. The "Users" section describes how to safely operate the boiler.
USERS SECTION
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] If the terminal is fitted within 850mm of a plastic or painted gutter or 450 mm of painted eaves, an aluminium shield of a minimum length 750 mm should be fitted to the underside of the gutter or painted surface. Terminal guard If a terminal guard is required, a suitable guard with integral deflector can be obtained from your supplier, Saunier Duval part number 85373. Cupboard or compartment ventilation The boiler can be fitted in a cupboard or compartment as long as adequate permanent high and low level ventilation is provided in accordance with ventilation requirements.
16
Ins 012a
BOILER LOCATION
Diagram. 26
Minimum dimensions (in mm) for the positioning of flue terminals A B C D E F G H I L M N under a window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600 under an air vent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600 under a gutter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300 under a balcony . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300 from an adjacent window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400 from an adjacent air vent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600 from vertical or horizontal air pipes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600 from an external corner of the building . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300 from an internal corner of the building. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000 from the ground or from another floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1800 between two terminals vertically . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1500 between two terminals horizontally . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000
G O C E P A B D I H L F M
N
17
Ven 060a
BOILER INSTALLATION
Statutory requirements The installation of this boiler must be carried out by a competent person in accordance with the relevant requirements of the current issue of: The Gas Safety (Installation and Use) Regulations The Building Regulations The local water company Byelaws The Building Standards Regulations (Scotland) The Health and Safety at Work Act Sheet metal parts WARNING. When installing or servicing this boiler, care should be taken when handling the edges of sheet metal parts to avoid the possibility of personal injury. Installing the boiler Prior to starting work, the system must be thoroughly flushed with a suitable cleaning agent so as to eliminate any foreign bodies and contaminants such as filings, weld particles, oil, grease etc. NOTE : solvent products could cause damage to the system.
q Engage boiler upper part onto the retaining strip (diagram 27). q Allow the boiler to seat down into position onto the support plate (diagram 28). q Fit the filter and washers, strictly adhering to the sequential order and directions shown on diagram 23. Connect the various couplings between the boiler and connection plate.
Diagram. [. . . ] Air in the heating system Persistent air in the heating system may indicate leaks in the system or corrosion taking place. Call the nearest after sales service department.
Diag. 58
SETTINGS
Setting the heating output The heating output of the boiler can be set between the minimum and maximum values given in the Technical Data, page 10. q Connect a suitable pressure gauge to the main burner test point as described previously. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SAUNIER DUVAL THELIA 23
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.