If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SAUNIER DUVAL THEMA CLASSIC F18E SB. We hope that this SAUNIER DUVAL THEMA CLASSIC F18E SB user guide will be useful to you.
Lastmanuals help download the user guide SAUNIER DUVAL THEMA CLASSIC F18E SB.
Manual abstract: user guide SAUNIER DUVAL THEMA CLASSIC F18E SB
Detailed instructions for use are in the User's Guide.
[. . . ] 4000124050-2 10. 03
Instructions for Use Installation and Servicing
To b e l e f t w i t h t h e u s e r
Themaclassic F24E
Fanned Flue Combination Boiler G. C. No. 47-047-35
Themaclassic F18E SB
Fanned Flue System Boiler G. C. No. 41-920-35
F24E shown
Hepworth Heating Ltd. , Nottingham Road, Belper, Derbyshire. DE56 1JT
Guarantee Registration
Thank you for installing a new Saunier Duval appliance in your home. [. . . ] External controls should be fitted in accordance with the rules in force.
EXTERNAL FROST THERMOSTAT
X
STRAIN RELIEF
MAINS CABLE
EXTERNAL CONTROLS CABLE Diagram 11. 4
F24E only
TO MAIN PCB CONNECTOR J15
CONTROLS INTERFACE PCB
3 2 1
DO NOT CONNECT MAINS VOLTAGE HEATING CONTROLS CONNECTION PLUG
VOLTAGE FREE HEATING CONTROLS CONNECTION (ON CONTROLS BOX COVER)
REMOVE LINK WHEN ANY EXTERNAL CONTROLS ARE USED
11. 4 Electrical Connections - Testing
Carry out preliminary electrical system checks as below:
PROGRAMMER
ON/OFF SWITCH
1. Test insulation resistance to earth of mains cables. Test the earth continuity and short circuit of cables. Test the polarity of the mains.
EXTERNAL ROOM THERMOSTAT
EXTERNAL JUNCTION BOX 3 AMP FUSE
INTERNAL PROGRAMMER
9762
CONTROL PANEL USER INTERFACE RETAINING LATCHES
EXTERNAL 230V AC ROOM THERMOSTAT EXTERNAL 230V AC FROST THERMOSTAT
DOUBLE POLE ISOLATOR
L N E
230V~ 50Hz PERMANENT MAINS SUPPLY
CONTROLS INTERFACE PCB
3 2 1
The type of plug and orientation may be different to that illustrated but the wiring should always be as wiring diagrams PLUG
11974
EXTERNAL CONTROLS CABLE(MAINS VOLTAGE)
EXTERNAL FROST THERMOSTAT
X
DO NOT CONNECT MAINS VOLTAGE HEATING CONTROLS CONNECTION PLUG
VOLTAGE FREE HEATING CONTROLS CONNECTION (ON CONTROLS BOX COVER)
REMOVE LINK WHEN ANY EXTERNAL CONTROLS ARE USED
EXTERNAL ROOM THERMOSTAT
ON/OFF SWITCH EXTERNAL PROGRAMMER
EXTERNAL JUNCTION BOX 3 AMP FUSE
EXTERNAL PROGRAMMER/CLOCK EXTERNAL 230V AC ROOM THERMOSTAT
DOUBLE POLE ISOLATOR
L N E
CONTROLS INTERFACE PCB Diagram 11. 3
EXTERNAL 230V AC FROST THERMOSTAT
230V~ 50Hz PERMANENT MAINS SUPPLY
Diagram 11. 5
4000124050-2
26
11993
F18E SB only
TO MAIN PCB CONNECTOR J15
11992
12 Commissioning
Important: The commissioning and first firing of the boiler must only be done by a competant person.
Air in pipes
Important: A central heating system can not operate correctly unless it is filled with water and air bled from the system. If these conditions are not met the system may be noisy. Bleed the air in the radiators and adjust the pressure if system requires. If the system requires filling to often this may be due to minor leaks or corrosion in the system.
Gas installation
If conversion from G20 to 30 or 31 is required, refer to section 13. It is recommended that any air is purged from the supply at the gas purge point on the gas valve, see diagram 12. 1.
Filling the system
The following steps 1 - 8, show how to fill the system.
BURNER PRESSURE POINT GAS PURGE POINT
1.
Make sure that:
· The boiler is connected to the electrical supply. Turn the switch OFF ( 0 )
11898
F24E shown 2. · Open the three water isolating valves.
Diagram 12. 1
Note: Isolating valves are shown in the: OFF position
HEATING RETURN F24E shown
COLD WATER IN (F24E Only)
HEATING FLOW
DOMESTIC HOT WATER OUT (F24E Only)
GAS SERVICE COCK
3. · Undo cap on automatic air vent on top of pump and leave undone.
9810
4. · Turn the switch ON ( I ) · F24E Only Open the tap on the filling device · Fill the system until the pressure indicated on the display is 1 bar. Close filling device.
9792
NOTE: On initial fill there may be a small discharge of water from the Reduced Pressure Zone valve
27
4000124050-2
9796
12 Commissioning
5. · Bleed each radiator to remove air, ensure all bleed screws are re-tightened. · If necessary repressurise the system, refer to procedure 4
Ins 061a
Adjusting the Central heating output.
The central heating output is factory preset to approx. If a different central heating output is required, proceed as follows: To gain access to potentiometer P3, unclip the control box, see diagram 11. 1.
10217
The potentiometer P3, is shown in diagram 12. 2, to adjust to the required heating output, insert a small flat edge screw driver into the arrowed slot in potentiometer P3, turn clockwise to adjust to the desired setting. Use a manometer to monitor the burner pressure.
MANOMETER
P. max.
15 kW
maxi
15 kW
maxi
mini
P3
POTENTIOMETER P3
mini
P3
ON
1
P6
POTENTIOMETER P6
SW1 DIP SWITCH
0
P7
P6
Factory set in "OFF" position
USER INTERFACE BOARD Diagram 12. 2
ON
1
+
Dip Switches
The position of the SW1Dip Switch(s), see diagram 12. 2, and the table below can be used to change the operation of the PUMP OPERATION WITH BURNER WITH HEATING DEMAND FACTORY SETTING
4000124050-2
pump and maximum heating temperature of your boiler.
DIP SWITCH 1 ON OFF*
* GB/IE PREFFERED SETTING 28
12066
Ins 062a
7. · Ensure the display indicates a system pressure of 1. 0 bar adjust if necessary.
8. · Open various hot water taps to bleed system
9810
6.
· Leave cap open on automatic air vent.
12 Commissioning
When all adjustments are completed. · Adjust heating temperature to maximum. · Check that any external controls, if fitted, are calling for heat (set room thermostat to maximum). [. . . ] · Remove plate to plate heat exchanger from boiler. · Fit replacement plate to plate heat exchanger. Note: Plate to plate heat exchanger mounting screws are offset to ensure correct fitting.
F24E shown
Diagram 18. 24
4000124050-2
50
9771
9775
DOMESTIC HOT WATER PLATE TO PLATE HEAT EXCHANGER
Before starting refer to the front of Section 18 Important information.
18 Replacement of Parts
Renewal of the expansion vessel requires the boiler to be removed from the wall. As an alternative, a separate expansion vessel of the same specification may be connected as close as possible to the boiler, leaving the original in position, refer to the installation instructions. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SAUNIER DUVAL THEMA CLASSIC F18E SB
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.