If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SAUNIER DUVAL THEMA CLASSIC F35E. We hope that this SAUNIER DUVAL THEMA CLASSIC F35E user guide will be useful to you.
Lastmanuals help download the user guide SAUNIER DUVAL THEMA CLASSIC F35E.
Manual abstract: user guide SAUNIER DUVAL THEMA CLASSIC F35E
Detailed instructions for use are in the User's Guide.
[. . . ] 4000123924-2 07. 03
Instructions for Use Installation and Servicing
To b e l e f t w i t h t h e u s e r
Themaclassic F30E
Fanned Flue Combination Boiler G. C. No. 47-920-36
Themaclassic F30E SB
Fanned Flue System Boiler G. C. No. 41-920-45
Themaclassic F35E
Fanned Flue Combination Boiler G. C. No. 47-920-40
Hepworth Heating Ltd. , Nottingham Road, Belper, Derbyshire. [. . . ] The temperature rise will cause release of the air contained in the water of the central heating system. · Air driven towards the boiler will be automatically released through the automatic air vent. · The air trapped at the highest point of the system must be released by bleeding the radiators. Check the burner gas rate required, ten minutes after lighting. Refer to Data Label on electrical controls box. Should there be any doubt about the gas rate it should be checked at the meter, refer to technical data. On reaching maximum temperature, the boiler should be turned off and the system drained as rapidly as possible whilst still hot. · Refill system to a pressure of between 1 and 2 bar and vent as before. · Restart boiler and operate until a maximum temperature is reached. If necessary, refer to section 16 to adjust the bypass. Shut down boiler and vent heating system. If necessary, top up heating system and make sure that a pressure of at least 1 bar is indicated when system is COLD. F30E/F35E Only Flush the domestic hot water system by opening the hot water taps for several minutes. Completion Adjust the boiler temperature control and any system controls to their required settings. For IE, it is necessary to complete a "Declaration of
Conformity" to indicate compliance to I. S. 813. An example of this is given in the current edition of I. S. 813. Please ensure the "Benchmark" logbook is completed and left with the user and the magnetic lighting instruction label is placed on the surface of the boiler casing. Instruct the User Instruct and demonstrate the lighting procedure and advise the user on the safe and efficient operation of the boiler. Instruct on and demonstrate the operation of any heating system controls. Advise the user on the use and maintenance of any scale reducer and pass on any relevant instructional documents. Advise that to ensure the continued efficient and safe operation of the boiler it is recommended that it is checked and serviced at regular intervals. The frequency of servicing will depend upon the installation conditions and usage, but in general, once a year should be enough. [. . . ] · Remove the front panel, refer to Section 17. 3. · Lower the control panel, refer to Section 17. 4. · Drain down the boiler only , refer to relevant parts of diagram 20. 1. · Disconnect the fixing jig connection pipes at the boiler. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SAUNIER DUVAL THEMA CLASSIC F35E
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.