User manual SAUNIER DUVAL XEON 40FF

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SAUNIER DUVAL XEON 40FF. We hope that this SAUNIER DUVAL XEON 40FF user guide will be useful to you.

Lastmanuals help download the user guide SAUNIER DUVAL XEON 40FF.


Mode d'emploi SAUNIER DUVAL XEON 40FF
Download
Manual abstract: user guide SAUNIER DUVAL XEON 40FF

Detailed instructions for use are in the User's Guide.

[. . . ] 221657C. 02. 00 Instructions for Use Installation and Servicing To b e l e f t w i t h t h e u s e r 7336 40ff Fanned Flue Boiler (S. I. T. ) This is a Cat II2H3P Appliance Reference in these instructions to British Standards and Statutory Regulations/Requirements apply only to the United Kingdom. For Ireland the rules in force must be used. The instructions consist of three parts, User, Installation and Servicing Instructions, which includes the Guarantee Registration Card. The instructions are an integral part of the appliance and must, to comply with the current issue of the Gas Safety (Installation and Use) Regulations, be handed to the user on completion of the installation. Guarantee Registration Thank you for installing a new Saunier Duval appliance in your home. Saunier Duval appliances' are manufactured to the very highest standard so we are pleased to offer our customers' a Comprehensive First Year Guarantee. [. . . ] Now make sure that the top, swing brackets are UPRIGHT. Lift the boiler into position, hooking over the mounting bracket. Swing the brackets over the two screws at the top. Hold the swing bracket(s) in place whilst tightening the screw(s) onto it, see diagram 5. 3. Remove the blue and red electrical connections from the fan, see diagram 5. 4. Break the air pressure switch tube connections, see diagram 5. 4. Remove the fan assembly by removing the screws at the front, slackening the screws at the rear and sliding it out, see diagram 5. 4. Secure the flue assembly to the boiler using the previously fitted dogpoint screws noting that these are keyhole fixings, see diagram 5. 5. Make sure of the correct fitting of the flue to the boiler. For a side outlet cut the fan duct extension to the length required, see diagram 5. 6. Remove any burrs and fit as diagram 5. 6. Fit the fan duct extension to the elbow and assemble to the fan as shown in diagram 5. 6. Do not secure at this point with the screw. Position the fan assembly and engage the fan duct extension over the flue manifold. Make sure, by pushing the flue duct extension that a secure seal is made. Mark the final position of the fan duct extension through the screw hole on the elbow, remove the assembly and secure with the screw as diagram 5. 6. Secure the elbow to the fan outlet with the Jubilee clip. For rear outlet cut and fit the fan duct extension, as diagram 5. 6. Fit fan assembly by engaging the fan duct extension over the flue manifold spigot, see diagram 5. 7. Secure the fan assembly with the screws previously slackened and removed. Reconnect the blue and red electrical connections to the fan, the polarity of the connections is not important. Reconnect the air pressure switch tubes as shown in diagram 5. 4. [. . . ] Release the capillary from the retaining clips then remove it from the split grommet. Slacken the bracket and remove the phial from the pipe. When refitting use the heat sink compound provided and make sure that the phial is correctly fitted into the groove on the pipe. ELECTRICAL CONNECTIONS Diagram 10. 1 33 221657C 10 Replacement of Parts 4103 PHIAL RETAINING BRACKET SECURING SCREW OVERHEAT CUTOFF DEVICE PHIAL ELECTRICAL PLUGS BOILER THERMOSTAT ELECTRICAL CONNECTION NO. 3 "YELLOW" CABLE CONTROL THERMOSTAT PHIAL CHASSIS EARTH CONNECTION 4090 SECURING EARTH CONNECTION SCREW (2) MAIN TERMINAL STRIP SPLIT PIN SUPPORT POST (4) IGNITION LEAD RETAINING CLIP PLASTIC RETAINING CLIP NOTE: All capillaries and cable should be situated within the 'Gland seal'. GLAND SEAL (Right hand illustrated) Diagram 10. 2 ELECTRICAL PLUGS ELECTRICAL CONNECTION BLUE CABLE "N" ELECTRICAL CONNECTION BROWN CABLE "SL" Diagram 10. 2A 10. 4 Control Board (PCB) diagram 10. 2A Release the control box, refer to Section 5. 6. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SAUNIER DUVAL XEON 40FF

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SAUNIER DUVAL XEON 40FF will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag