Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SCHOLTES B 40 L CS F. We hope that this SCHOLTES B 40 L CS F user guide will be useful to you.
Lastmanuals help download the user guide SCHOLTES B 40 L CS F.
Detailed instructions for use are in the User's Guide.
[. . . ] Before connecting the appliance, make sure that the data on the rating plate (situated on the bottom part of the appliance and on the last page of the booklet) correspond to those of the mains electricity and gas supplies. Check that the capacity of the electrical system and the power outlets are suitable for the maximum power of the appliance, indicated on the rating plate. if in doubt , consult a professionally qualified technician. Do not leave the appliance plugged in if it is not in use. [. . . ] After cleaning, some special treatments are available to bring back the shine to steel and to prevent it from yellowing; for this purpose, we recommend you use the specific "special cream detergent for steel care" available from our Assistance Centres. The removable parts of the burners should be washed frequently with warm water and soap, making sure to remove caked-on substance. check that the gas outlet slits are not clogged. Dry the burners carefully before using them again. Do not use steam cleaners to clean your oven. Greasing the taps As time passes, a tap may lock or become difficult to turn. In this case it will be necessary to clean inside and replace the grease. This procedure must be performed by a technician authorized by the manufacturer. GB IE The following instructions are provided for qualified installers so that they may accomplish installation, adjustment and technical maintenance operations correctly and in compliance with current regulations and standards. Important: the hob should be disconnected from the mains electricity supply before any adjustment, maintenance, etc. Maximum caution should be used whenever it is necessary to keep the appliance connected to the electricity supply. The hobs have the following technical characteristics: -Category II 2H3+ - Class 1: all models whose edges are higher than/equal to 82 mm (see following page, fig. - Class 3: all models whose edges are lower than/equal to 82 mm (see following page, fig. Positioning This appliance may only be installed and operated in permanently ventilated rooms in compliance with provisions laid down by current regulations and standards. The following requirements must be observed: · The appliance must discharge combustion products into a special hood, which must be connected to a chimney, flue pipe or directly to the outside (Fig. If it is impossible to fit a hood, the use of an electric fan is permitted, either installed on a window or on an external wall, which must be switched on at the same time as the appliance. Total free cross section of passage of at least 6 cm² for every kW of rated heating capacity of the appliance, with a minimum of 100 cm² (the heating capacity is indicated on the rating plate); · It must be made in such a way that the aperture, both on the inside and outside of the wall, cannot be obstructed; · In such a way that the above-mentioned free section is not reduced; · It must be situated as near to floor level as possible. Enlarging the ventilation slot between window and floor The air inflow may also be obtained from an adjoining room, provided the latter is not a bedroom or a room where there is a risk of fire, such as garages, mews, fuel stores, etc. and is ventilated in compliance with the standards in force. Air from the adjoining room to the one to be ventilated may be made to freely pass through permanent apertures with a cross section at least equal to that indicated above. These apertures may also be obtained by increasing the gap between the door and the floor (Fig. If an electric fan is used for extracting the combustion products, the ventilation aperture must be increased in relation to its maximum performance. [. . . ] The supply cable must be in such a position that no part of it can reach a temperature of 50 °C above room temperature. For installation above a built-under oven, the hob and the oven must be connected separately to the electricity supply both for safety reasons and for easy removal of the oven if necessary. Do not use adapters or shunts as they could cause heating or burning. Before connecting to the power supply, make sure that: · The limiter valve and the domestic system can withstand the load from the appliance (see rating plate); · the supply system is efficiently earthed according to standards and laws in force; · The socket or double-pole switch are easily accessible when the appliance is installed. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SCHOLTES B 40 L CS F
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SCHOLTES B 40 L CS F will begin.