User manual SCHOLTES PP 40 DCDR SF

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SCHOLTES PP 40 DCDR SF. We hope that this SCHOLTES PP 40 DCDR SF user guide will be useful to you.

Lastmanuals help download the user guide SCHOLTES PP 40 DCDR SF.


Mode d'emploi SCHOLTES PP 40 DCDR SF
Download
Manual abstract: user guide SCHOLTES PP 40 DCDR SF

Detailed instructions for use are in the User's Guide.

[. . . ] Please keep this instruction booklet in a safe place for future reference. If the appliance is sold, given away or moved, please make sure the booklet is also passed on to the new owners so that they may benefit from the advice contained within it. The system can also provide the air needed for combustion indirectly, i. From adjacent rooms fitted with air circulation ducts as described above. [. . . ] checking the tightness of the connection !When the installation process is complete, check the pipe fittings for leaks using a soapy solution. Adapting to different types of gas To adapt the hob to a different type of gas other than the default type (indicated by the label placed on the lower part of the hob or on the packaging), the burner nozzles should be replaced as follows: Unscrew the nozzles using a 7 mm socket spanner, and replace them with nozzles for the new type of gas (see table 1 "Burner and nozzle specifications"). Reassemble the parts, following the above procedure in the reverse order. Once this procedure is finished, replace the old rating sticker with one indicating the new type of gas used. Stickers are available from any of our Technical Assistance Centres. The burner consists of two separate parts (see Figures). The inner burner has one nozzle and the outer burner has two (these are the same size). Replace the nozzles with models which are suitable for use with the new type of gas (Table 1). Replace all the components by following the above instructions in reverse. Turn the tap to its minimum setting position. Remove the knob and adjust the adjustment screw, which is positioned in or next to the tap pin, until the flame is small but steady. Having adjusted the flame to the required low setting, while the burner is alight, quickly change the position of the knob from minimum to maximum and vice versa several times, making sure that the flame is not extinguished. Some appliances have a safety device (thermocouple) fitted. If the device fails to work when the burners are set to the low flame setting, increase this low flame setting using the adjustment screw. Once the adjustment has been made, replace the seals on the by-passes using sealing wax or a similar substance. Once this procedure is complete, replace the old rating sticker with one indicating the new type of gas used. Stickers are available from any of our Technical Assistance Centres. If the gas pressure used is different (or varies slightly) from the recommended pressure, a suitable pressure regulator must be fitted to the inlet pipe (in order to comply with current national regulations relating to "regulators for channelled gas"). The hob can only be installed above built-in ovens with a cooling ventilation system. Select the most suitable burner in accordance with the diameter of the cookware you wish to use. Each burner can be adjusted to one of the following settings using the corresponding control knob: 0 Off Maximum Minimum To light one of the burners, hold a lit match or lighter near the burner and, at the same time, press down and turn the corresponding knob anti-clockwise until it reaches the maximum setting. [. . . ] The removable parts of the burner should be washed regularly with warm water and soap, ensuring any stubborn residue is removed. For hobs which light automatically, the terminal part of the electronic instant lighting devices should be cleaned frequently and the gas outlet holes should be checked for blockages. Stainless steel can be marked by hard water that has been left on the surface for a long time, or by aggressive detergents containing phosphorus. After cleaning, rinse well and dry thoroughly. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SCHOLTES PP 40 DCDR SF

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SCHOLTES PP 40 DCDR SF will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag