Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SCHOLTES TT 6134. We hope that this SCHOLTES TT 6134 user guide will be useful to you.
Lastmanuals help download the user guide SCHOLTES TT 6134.
Detailed instructions for use are in the User's Guide.
[. . . ] Therefore, rooms containing LPG cylinders must also be equipped with vents to allow gas to escape in the event of a leak. As a result LPG cylinders, whether partially or completely full, must not be installed or stored in rooms or storage areas which are below ground level (cellars, etc. It is advisable to keep only the cylinder currently being used in the room, positioned so that it is not subject to heat produced by external sources (ovens, fireplaces, stoves, etc. ) which could raise the temperature of the cylinder above 50°C. [. . . ] After replacing the nozzles, change the hob setting using the control panel as follows: While the hob is switched off, press the power button T1. Press the lock button T2 (D1 lights up). Press the buttons T2, T7 and T11 simultaneously, holding them down until a numerical value appears on the display D2. At this point, with the hob set to methane G20 20 mbar, the display shows 01; to convert the hob to operation with G30 29 mbar, press the T4 button once, so that the value 02 appears on the display D2. The hob will allow 2 adjustments to be made: 01 and 02, which correspond to G20 20 mbar and G30 29 mbar respectively. To save the new setting, press the buttons T2, T7 and T11 simultaneously (hold them down for a few seconds, until you exit the function  approximately 5 seconds); the hob will appear to be switched off with the keypad locked. press the unlock button T2 to operate the hob. NOTE: if, during the gas conversion procedure, no buttons are pressed for a period of longer than 1 minute, the appliance automatically exits the function without saving the new setting. Once this procedure is complete, replace the old rating sticker with one indicating the new type of gas used. Stickers are available in nozzle kits or can be obtained from any of our Technical Assistance Centres. Setting the burners to minimum (only for gasG20) While the hob is switched off, press the power button T1. If the + button is pressed, the burner is ignited in its safety mode and after approximately 3 seconds automatically begins operating at its minimum power level; at this point, if you continue pressing the + button, it is possible to increase the power level until it reaches level 9 (max). If the  button is pressed, the burner is ignited in its safety mode and after approximately 3 seconds begins operating at its maximum power level (power level 9) and remains there; at this point, if you continue pressing the  button, it is possible to decrease the power level until it reaches level 1 or the burner is switched off (level 0). SWITCHING OFF A BURNER Press the + and  buttons corresponding to the burner you wish to switch off simultaneously. alternatively: Press the  button until level 0 is reached. Alternatively: Press button T1 (all burners switch off, even if the lock function has been activated; window D1 is activated). When the hob is ON and the burners switched off, if no activity is detected on the keypad after 1 minute, a buzzer sounds and the keypad is locked (the display D1 is activated); after a further minute a buzzer sounds again and the hob switches off once and for all, with the keypad remaining locked. Nevertheless, in every operating status (off, hob on and burners off, or hob and burners on), after 1 minute of inactivity on the keypad it will become locked. After an hour of operation with no adjustments made to a particular burner, the burner will switch off. To achieve the maximum burner performance level, we recommend that only cookware with a suitable diameter for the relevant burner is used, thereby preventing the flame from leaking out from under the base of the pan (see table below). Furthermore, when a liquid begins to boil, we recommend that the flame is reduced to the lowest level possible to keep the pan contents boiling. To ensure the burners operate efficiently: All types of deep casserole dish may be used on the burners, as long as the edges of the cookware do not overlap the perimeter of the hob. [. . . ] Exhausted appliances should be collected separately in order to optimise the cost of re-using and recycling the materials inside the machine, while preventing potential damage to the atmosphere and to public health. The crossed-out dustbin is marked on all products to remind the owner of their obligations regarding separated waste collection. Exhausted appliances may be collected by the public waste collection service, taken to suitable collection areas in the area or, if permitted by current national legislation, they may be returned to the dealers as part of an exchange deal for a new equivalent product. Disconnect your appliance from the electricity supply before carrying out any work on it. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SCHOLTES TT 6134
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SCHOLTES TT 6134 will begin.