Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SCICAN QUANTIM B. We hope that this SCICAN QUANTIM B user guide will be useful to you.
Lastmanuals help download the user guide SCICAN QUANTIM B.
Detailed instructions for use are in the User's Guide.
[. . . ] B
· Operator's Manual
Copyright 2003 SciCan. All rights reserved.
Rev 1. 0
www. scican. com
Quantim B Table of Contents P2 P3 Decals, displays and controls Introduction - Types of load and loading - Key to Pictures Operation Operation (continued) - Additional Operations Essential information Troubleshooting Additional Information Specifications Contact
P4 P5 P P P P 6 7 8 9
Quote your model details, serial number and date of purchase when contacting your supplier
All rights reserved. QUANTIM is a trademark of SciCan, Division of Lux and Zwingenberger Ltd.
For all service and repair inquiries: In Canada/United States: 1-800-870-7777 International: (416) 446-4500 Email (Service and Repair): techservice. ca@scican. com
SciCan
1440 Don Mills Rd Toronto Ontario M3B 3P9 Phone: (416) 445 -1600 Fax: (416) 445 -2727 Toll Free: 1- 800 - 667 - 7733
SciCan Medtech AG
Alpenstrasse 16, 6300 Zug, Switzerland Phone: (41-41) 727 -7027 Fax: (41-41) 727 -7029
EU Representative:
SciCan
MesserschmittStr. 11 D - 86368 Gersthofen Germany 1
Quantim B S1
L
K
S5 N
J
S1 S5 S2
B
L1
M
S3
E
L2
F1
L3 C1ii C1i C2ii C2i S4
F2
G H I
L4 L5 L6 L7 L8
C D
C3 C5
C4
2
Quantim B Introduction
Thank you for choosing the SciCan QUANTIM B autoclave. [. . . ] the default time of 06. 30 will be shown. If another time is required for the auto-cycle start, change minutes then hours; by pressing button (E) up and (F1) down and button (F2) to accept. · The unit returns to the ready mode and the `time display' (L1) continues to flash. You can scroll through the settings as a check. · Select the required sterilizing cycle using buttons (G), (H), and (I). A visual display shows the stages of the cycle: Stage 1 - Cycle started (L4) Stage 2 - Heating and air bleed (L5) Stage 3 - Sterilizing (L6) Stage 4 - Depressurisation/drying (L7) Stage 5 - Cycle complete (L8) 11. Opening door At the end of a cycle the buzzer sounds 3 times. Press button (D) to open the door, allowing access to the load.
Note: If the unit is used in a very cold environment, water vapour may be seen coming from the cooling fan. This is normal and will only last for a few minutes.
* Cycle C2i not included in compliance with prEN13060
5
Quantim B Essential Information
To ensure the autoclave continues to operate correctly, it is important to follow the following points and to carry out the necessary care and maintenance procedures as specified. you read and follow these operating instructions. the load is suitable for sterilization and the cycle selected. the load can be sterilized at the selected temperature. the load has been rinsed thoroughly in clean water prior to sterilization to avoid any chemical residues left after cleaning. This product is not a washing / cleaning machine. when placing instruments on trays, ensure that they are placed on the ribs of the tray (to help drainage), that they do not touch each other and that the height of the load does not interfere with the tray or chamber above. only distilled, de-ionised or sterile water is used (as recommended). the autoclave is in a draught free area. the autoclave cooling fan outlet is at least 100mm from any nearby surface. If the nearby surface is cold, then condensation may occur. the autoclave is not installed in an enclosed cupboard space' . . . all other exterior product panels are 50mm clear of adjoining surfaces to allow air circulation. the autoclave is positioned so that the rear is not accessible to personnel and that it is not directly in front of an electrical outlet so as to allow the over-pressure release valve to operate safely. [. . . ] Before moving always allow 30 minutes after use for the unit to cool down Cleaning materials: - mild washing up liquid. - disinfectant diluted in water - Autoclave Cleaning Kit - 289138 Product decontamination. Should the unit require repair, it must be decontaminated in accordance with a recognised procedure prior to return or on-site repair. Approvals: Approvals are all model specific. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SCICAN QUANTIM B
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SCICAN QUANTIM B will begin.