Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SCOTSMAN C2648R. We hope that this SCOTSMAN C2648R user guide will be useful to you.
Lastmanuals help download the user guide SCOTSMAN C2648R.
Detailed instructions for use are in the User's Guide.
[. . . ] Installation and User's Manual for Remote Condenser Modular Cuber Model C2648R
C2648 Remote Condenser Models - User Manual Introduction
The design of this modular remote cuber is the result of years of experience with remote ice machine refrigeration systems. Standard features of this product include front accessible on-off switches, always-visible indicator lights, mechanical assist ice harvest for extra efficiency, automatically adjusting water purge and a control system that optimizes system operation. This installation and user manual is divided into three sections: Installation, Use and Operation and Maintenance. The Installation section provides the trade person with the information needed to properly install and start up this ice system. [. . . ] Is the unit located where it can receive adequate cooling air?Has the correct electrical power been supplied to the machine?Have all the water supply connections been made?Have all the drain connections been made?Has the remote condenser been properly installed?Has the interconnecting tubing been properly routed between the remote condenser and the ice machine?Have the quick connects been properly connected?Has the power supply wire from the ice machine to the remote condenser been properly run and connected?Have all unpacking materials been removed?Have the drain connections been checked for leaks?Has the bin interior been wiped clean or sanitized?Have any water filter cartridges been replaced?Have all required kits and adapters been properly installed?
October 2010 Page 14
C2648 Remote Condenser Models - User Manual Initial Start Up
1. Check machine for any packing or wires rubbing moving parts. Note location of control board in upper left corner of the machine's front. Switch on the electrical power to the machine. Observe that some of the control's indicator lights glow and its display shows O. Wait 4 hours for the compressor's crankcase heater to warm up the oil in the compressor. Turn the receiver's outlet valve to the full open position. The indicator light will begin to blink F. The purge valve will open and the water pumps will start. The inlet water valve will open to add water to the reservoir. [. . . ] Technical Highlights Water Level Sensor The water sensor probes and probe housing must be cleaned regularly. Squeeze catches together and pull up to remove sensor. Separate probes from housing and wash all surfaces with ice machine scale remover solution. Release probes by pushing in on white buttons and pulling probe down out of holder.
· · · · ·
3 Evaporators 3 Thermostatic Expansion Valves 3 Harvest Assist Solenoids 3 Hot Gas Valves 1 OPR valve
Ice making or the freeze cycle is controlled by an ice thickness sensor on the far left evaporator. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SCOTSMAN C2648R
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.