User manual SCOTSMAN CME1002R

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SCOTSMAN CME1002R. We hope that this SCOTSMAN CME1002R user guide will be useful to you.

Lastmanuals help download the user guide SCOTSMAN CME1002R.


Mode d'emploi SCOTSMAN CME1002R
Download
Manual abstract: user guide SCOTSMAN CME1002R

Detailed instructions for use are in the User's Guide.

[. . . ] CME865R & CME1002R INTRODUCTION This manual is intended as a reference for the installation and service of a Scotsman ice maker model CME865R or CME1002R. This model is a remote condenser cuber, 30" wide and should be connected to a Scotsman remote condenser. Table of Contents INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 14 Page 15 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 26 Page 27 Page 31 Page 32 PRE-INSTALLATION INFORMATION ICE MACHINE SPECIFICATIONS RCE1001 SPECIFICATIONS . FOR THE INSTALLER: Environmental Limitations . [. . . ] Harvest is preset at 2 and a quarter minutes. Hot Gas Solenoid Valve The hot gas solenoid valve opens only during the harvest cycle. When it opens, it diverts the hot discharge gases so that they flow directly into the evaporator plates, by-passing the condenser and thermostatic expansion valve. The hot gases warm the evaporators, releasing the ice cubes from the ice cube molds. The hot gas solenoid valve is installed in a branch of the discharge line from the compressor, and when the timer switches the ice machine into the harvest cycle, the energized solenoid coil lifts the valve stem within the valve body, allowing the hot discharge gas to be diverted to the evaporators. High Temperature Cut Out This temperature sensor is located next to the hot gas valve, on the outlet side. During normal operation, it does not affect the ice machine, but it will shut the machine off if the hot gas line overheats. It is an automatic reset. September, 1994 Page 15 CME865R & CME1002R COMPONENT DESCRIPTION Ice Level Control This electronic control uses sound waves to measure the distance between the bottom of the ice machine and the top of the ice in the bin. It is designed to control the machines ice production to maintain that distance. The control is adjustable so that the ice machine will maintain a certain height of ice. It will not fill any closer to the ice machine than 8", and will not work if the distance to the bottom of the bin is greater than 8 feet. Because it uses sound waves, a slight "ticking" sound can be heard coming from the bottom of the machine. ON/OFF/WASH SWITCH ICE LEVEL SELECTOR SWITCH THE USER CAN SELECT THE AMOUNT OF ICE TO BE MAINTAINED IN THE BIN. FULL PARTIAL September, 1994 Page 16 CME865R & CME1002R COMPONENT DESCRIPTION Electric Water Inlet Valve The water inlet solenoid valve fills the reservoir assembly with water. Excess water overflows out the overflow standpipe located at the back of the reservoir. This action fills and rinses the reservoir during each harvest cycle. Water Distribution System The water distribution system evenly supplies water to all cells of the evaporator plates. The water pump pumps water from the reservoir up the vertical tygon tube to the tee. From there water is channeled through the water manifold to the water distributors, above each evaporator plate, and from six holes within each distributor, water flows to the cells of each side of the evaporator plates. Gravity flow returns the unfrozen excess portion of water to the reservoir for recirculation. Reservoir The reservoir, located below the evaporators, stores the inlet water charge, and collects the water that flows over the evaporator plates. High Pressure Safety Control This is a manual reset control that shuts down the ice maker, should the discharge pressure ever reach 450 PSIG. WATER DISTRIBUTION SYSTEM EVAPORATOR WATER PUMP RESERVOIR HIGH PRESSURE CUT OUT ELECTRIC WATER VALVE September, 1994 Page 17 CME865R & CME1002R SERVICE SPECIFICATIONS: CME865R The following numbers may be used as a guideline. There will be some variation from unit to unit. 0/70/55 14 - 15 minutes 26 PSIG 210 PSIG 75 PSIG 150 PSIG 90/90/70 15 - 16 minutes 2 minutes 28 PSIG 235 PSIG 100 PSIG 200 PSIG 120/110/100 26 - 27 minutes 2 minutes 35 PSIG 330 PSIG 160 PSIG 292 PSIG Typical Cycle Time Typical Freeze Cycle Low Side Pressure (end of cycle) Typical Freeze Cycle Discharge Pressure (end of cycle) Typical Harvest Cycle Low Side Pressure (peak) Typical Harvest Cycle Discharge Pressure (min) Harvest Time (2 2/3 min. [. . . ] 56 114 146 · When brazing the tubing connections to components such as the 58 118 148 TXV, the component must be protected by heat sink material. 60 123 150 Recover, reclaim or recycle refrigerant. The method chosen is up to 62 127 152 the service company. Any refrigerant placed into a Scotsman ice machine 64 132 154 must meet ARI spec 700-88. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SCOTSMAN CME1002R

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SCOTSMAN CME1002R will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag