User manual SCOTSMAN FME2400

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SCOTSMAN FME2400. We hope that this SCOTSMAN FME2400 user guide will be useful to you.

Lastmanuals help download the user guide SCOTSMAN FME2400.


Mode d'emploi SCOTSMAN FME2400
Download
Manual abstract: user guide SCOTSMAN FME2400

Detailed instructions for use are in the User's Guide.

[. . . ] NME1850 & FME2400 INTRODUCTION To the owner or user: The service manual you are reading is intended to provide you, and the maintenance or service technician, with the information needed to install, start up, clean, maintain, and service this ice system. This product contains 2 separate ice making systems in one cabinet. TABLE OF CONTENTS Installation For the Installer Specifications . 5 For the Plumber Final Check List Start Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Drain the evaporator by pulling down and uncapping the evaporator drain tube. After the auger has been removed, allow the auger to dry: if the auger is not bright and shiny, it must be cleaned. Clean the auger and evaporator as required. Reverse to reassemble. January 1994 Page 19 NME1850 & FME2400 SERVICE DIAGNOSIS: Condition - No Ice Being Produced STATUS: NOTHING OPERATES A. Check: Voltage to the unit, restore it if there is none. Check: The master switch , switch ON if off. Check: The 2 reset switches , (high and low pressure): depress and release each switch. If the still does not start, check: the spout switch; the high and the low side pressures. Check the low pressure cut out, if closed, go to E; if it is open, it could be due to: ·Low refrigerant charge ·The auger not turning ·Restricted system ·TXV not opening 1. Check the low side pressure, the low pressure cut out opens at pressure below 4 psig. Check if the auger is turning, if it is not, remove the gearbox and: Check for internal damage, repair and replace in the machine. Check for low charge, add some refrigerant, if the unit will operate, (normal low side pressure being about 32 psig) stop and look for a leak, recover, repair, replace the drier, evacuate, and weigh in the nameplate charge. If, with added charge, the unit does not operate: Check for a restricted system, replace the drier, evacuate, and weigh in a nameplate charge. Check for a Thermostatic Expansion Valve that does not open, if defective, replace it. Replace the drier, evacuate, and weigh in the nameplate charge. Check the high pressure cut out, if closed, go to F; if open check: 1. Check the high side pressure, reset the control, and observe: on water cooled, that water soon begins to flow from the condenser drain; or, on air cooled, that the fan is forcing air through the condenser. If the unit trips out on pressures below 400 psig, replace the control. If the pressures rise above the trip out point, and the unit shuts down: a. Check for adequate water flow on water cooled, if adequate, clean the interior of the condenser. If the pressures are still too high replace the water regulating valve. Check for adequate air flow on air cooled. [. . . ] The remove the core cap. ·Close the valve and replace the caps when the job is finished. The valve must be closed and the caps must be on or the valve will leak. ALLEN WRENCH Torque Stem to 6-8 ft. (DEG F) (PSIG) DEG F) (PSIG) -20 17 70 146 -18 18 72 150 -16 20 74 155 -14 21 76 161 -12 23 78 166 -10 24 80 171 -8 26 82 177 -6 28 84 182 -4 29 86 188 -2 31 88 194 0 33 90 200 2 35 92 206 4 37 94 212 6 39 96 219 8 41 98 225 10 43 100 232 12 46 102 239 14 48 104 246 16 50 106 253 18 53 108 260 20 55 110 268 22 58 112 275 24 60 114 283 26 63 116 291 28 66 118 299 30 69 120 307 32 72 122 316 34 75 124 324 36 78 126 333 38 81 128 342 40 85 130 351 42 88 132 360 44 91 134 370 46 95 136 379 48 99 138 389 50 102 140 399 52 106 142 409 54 110 144 420 56 114 146 430 58 118 148 441 60 123 150 452 62 127 152 464 64 132 154 475 66 136 156 487 68 141 158 499 January 1994 Page 31 NME1850 & FME2400 CIRCUIT BOARD TESTING WARNING These procedures require the machine to be connected to the power supply. The voltages of the electronic circuit are very low, but HIGHER VOLTAGES ARE PRESENT IN THE UNIT. Do not touch anything but the tester while the unit is being checked out. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SCOTSMAN FME2400

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SCOTSMAN FME2400 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag