If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SEAGATE SAVVIO 10K.4 SAS. We hope that this SEAGATE SAVVIO 10K.4 SAS user guide will be useful to you.
Lastmanuals help download the user guide SEAGATE SAVVIO 10K.4 SAS.
Manual abstract: user guide SEAGATE SAVVIO 10K.4 SAS
Detailed instructions for use are in the User's Guide.
[. . . ] Product Manual
Savvio 10K. 4 SAS
®
Standard Models
Self-Encrypting Drive Models
ST9600204SS ST9450404SS
ST9600104SS ST9450304SS
100539221 Rev. A December 2009
Revision history
Revision Date Sheets affected or comments
Rev. A
12/15/09
Initial release.
Copyright © 2009 Seagate Technology LLC. A December 2009 Seagate, Seagate Technology and the Wave logo are registered trademarks of Seagate Technology LLC in the United States and/or other countries. [. . . ] There is no additional drain on the 12V supply.
Savvio 10K. 4 SAS Product Manual, Rev. A
21
Table 2:
600GB standard drive DC power requirements 600GB standard model 3. 0Gb mode Notes (Amps) +5V [5] [1] [7] ±5% 0. 33 (Amps) +12V [2] ±5% [2] 0. 24 600 GB standard model 6. 0Gb mode (Amps) +5V ±5% 0. 34 (Amps) +12V [2] ±5% [2] 0. 24
Voltage Regulation Avg idle current DC Advanced Idle Current Idle_A Idle_B Idle_C Standby Transition Current Idle_A - Active Idle_B - Active Idle_C - Active Standby - Active Maximum starting current (peak DC) DC (peak AC) AC Delayed motor start (max) DC Peak operating current (random read): Typical DC Maximum DC Maximum (peak) DC Peak operatig current (random write) Typical DC Maximum DC Maximum (peak) DC Peak operating current (sequential read) Typical DC Maximum DC Maximum (peak) DC Peak operating current (sequential write) Typical DC Maximum DC Maximum (peak) DC 3 3 3 3 3 3 3 3 [1] [6] [1] 3 3 3 [3] [3] [1] [4] 3 3 3 3 3 3 3 3
0. 32 0. 23 0. 23 0. 23
0. 24 0. 21 0. 11 0. 06
0. 33 0. 24 0. 24 0. 24
0. 24 0. 21 0. 10 0. 05
0. 72 0. 68 0. 64 0. 64
1. 58 1. 53 1. 53 1. 61
0. 70 0. 66 0. 66 0. 68
1. 42 1. 51 1. 51 1. 61
0. 51 0. 75 0. 46
0. 87 1. 63 0. 07
0. 53 0. 86 0. 47
0. 87 1. 65 0. 07
0. 43 0. 44 1. 06
0. 51 0. 52 1. 54
0. 44 0. 46 1. 10
0. 51 0. 52 1. 52
0. 48 0. 49 1. 02
0. 42 0. 44 1. 54
0. 50 0. 50 1. 04
0. 42 0. 44 1. 56
0. 82 0. 86 1. 12
0. 26 0. 27 0. 42
0. 84 0. 88 1. 16
0. 27 0. 27 0. 42
0. 80 0. 82 1. 02
0. 25 0. 27 0. 66
0. 81 0. 83 1. 04
0. 25 0. 27 0. 76
22
Savvio 10K. 4 SAS Product Manual, Rev. A
Table 3:
450GB standard model DC power requirements 450GB standard model 3. 0Gb mode Notes (Amps) +5V [5] [1] [7] ±5% 0. 34 (Amps) +12V [2] ±5% [2] 0. 24 450GB standard model 6. 0Gb mode (Amps) +5V ±5% 0. 35 (Amps) +12V [2] ±5% [2] 0. 24
Voltage Regulation Avg idle current DC Advanced Idle Current Idle_A Idle_B Idle_C Standby Transition Current Idle_A - Active Idle_B - Active Idle_C - Active Standby - Active Maximum starting current (peak DC) DC (peak AC) AC Delayed motor start (max) DC Peak operating current (random read): Typical DC Maximum DC Maximum (peak) DC Peak operatig current (random write) Typical DC Maximum DC Maximum (peak) DC Peak operating current (sequential read) Typical DC Maximum DC Maximum (peak) DC Peak operating current (sequential write) Typical DC Maximum DC Maximum (peak) DC 3 3 3 3 3 3 3 3 [1] [6] [1] 3 3 3 [3] [3] [1] [4] 3 3 3 3 3 3 3 3
0. 34 0. 24 0. 24 0. 24
0. 24 0. 21 0. 10 0. 06
0. 35 0. 25 0. 25 0. 25
0. 24 0. 21 0. 10 0. 06
0. 68 0. 66 0. 74 0. 68
1. 58 1. 54 1. 70 1. 64
0. 78 0. 66 0. 66 0. 70
1. 56 1. 54 1. 66 1. 60
0. 54 0. 80 0. 48
0. 87 1. 66 0. 07
0. 56 0. 85 0. 49
0. 87 1. 62 0. 07
0. 44 0. 47 1. 08
0. 53 0. 54 1. 54
0. 46 0. 48 1. 08
0. 53 0. 54 1. 54
0. 49 0. 52 1. 02
0. 44 0. 46 1. 58
0. 50 0. 53 1. 02
0. 43 0. 45 1. 56
0. 86 0. 88 1. 12
0. 27 0. 29 0. 44
0. 87 0. 89 1. 14
0. 27 0. 28 0. 44
0. 80 0. 85 1. 04
0. 27 0. 29 0. 80
0. 81 0. 86 1. 04
0. 27 0. 28 0. 80
[1]
Measured with average reading DC ammeter. Instantaneous +12V current peaks will exceed these values. N (number of drives tested) = 6, 35 Degrees C ambient.
Savvio 10K. 4 SAS Product Manual, Rev. A
23
[2]
[3] [4] [5] [6] [7]
For +12 V, a 10% tolerance is allowed during initial spindle start but must return to ±5% before reaching 9, 936 RPM. The ±5% must be maintained after the drive signifies that its power-up sequence has been completed and that the drive is able to accept selection by the host initiator. This condition occurs after OOB and Speed Negotiation completes but before the drive has received the Notify Spinup primitive. See paragraph 6. 3. 1, "Conducted noise immunity. " Specified voltage tolerance includes ripple, noise, and transient response. Operating condition is defined as random 8 block reads. During idle, the drive heads are relocated every 30 seconds to a random location within the band from three-quarters to maximum track.
24
Savvio 10K. 4 SAS Product Manual, Rev. A
General DC power requirement notes. Minimum current loading for each supply voltage is not less than 1. 7% of the maximum operating current shown. The +5V and +12V supplies should employ separate ground returns. Where power is provided to multiple drives from a common supply, careful consideration for individual drive power requirements should be noted. Where multiple units are powered on simultaneously, the peak starting current must be available to each device. Parameters, other than spindle start, are measured after a 10-minute warm up. 6. 3. 1 Conducted noise immunity
Noise is specified as a periodic and random distribution of frequencies covering a band from DC to 10 MHz. Maximum allowed noise values given below are peak-to-peak measurements and apply at the drive power connector.
+5v +12v = = 250 mV pp from 100 Hz to 20 MHz. 250 mV pp from 20 KHz to 5 MHz.
6. 3. 2
Power sequencing
The drive does not require power sequencing. The drive protects against inadvertent writing during power-up and down.
Savvio 10K. 4 SAS Product Manual, Rev. A
25
6. 3. 3
Current profiles
The +12V and +5V current profiles for the Savvio 10K. 4 drives are shown below.
F1
F2
Figure 16.
Current profiles for 600GB models
26
Savvio 10K. 4 SAS Product Manual, Rev. [. . . ] Submit pricing requests, orders and returns through a single, password-protected Web interface-anytime, anywhere in the world. spp. seagate. com spp. seagate. com supports Seagate resellers with product information, program benefits and sales tools. You may register for customized communications that are not available on the web. These communications contain product launch, EOL, pricing, promotions and other channel-related information. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SEAGATE SAVVIO 10K.4 SAS Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SEAGATE SAVVIO 10K.4 SAS will begin.