[. . . ] Product Manual
Constellation SAS
®
Standard Model
Self-Encrypting Drive Model
ST9500430SS
ST9500431SS
SED FIPS 140-2 Model
ST9500432SS
100538693 Rev. F February 2011
Revision history
Revision Date Sheets affected or comments
Rev. F
02/03/09 03/05/09 06/11/09 01/15/10 09/23/10 02/14/11
Initial release. fc, 1-2, 7, 9-10, 24-26, 35, 50 & 52. [. . . ] Once all outstanding commands are processed, the power condition timers are reinitialized to the values defined in the Power Condition mode page.
Constellation SAS Product Manual, Rev. F
21
7. 1. 1
PowerChoice reporting methods
PowerChoiceTM provides these reporting methods for tracking purposes: Request Sense command reports · Current power condition · Method of entry Note. Processing the Request Sense command does not impact the drive's power save state.
Mode Sense command reports (mode page 0x1A) · Idle conditions enabled / disabled · Idle condition timer values (100msec increments) (default, saved, current, changeable) Power Condition Vital Product Data (VPD) Page (VPD page 0x8A) · Supported power conditions · Typical recovery time from power conditions (1msec increments) Start/Stop Cycle Counter Log Page reports (log page 0x0E) · Specified and accumulated Start/Stops and Load/Unload cycles Power Condition Transitions Log Page reports (log page 0x1A, subpage 0x00) · Accumulated transitions to Active, Idle1, Idle2, Idle3, Standby2, Standby
7. 2
None.
AC power requirements
7. 3
DC power requirements
The voltage and current requirements for a single drive are shown below. Values indicated apply at the drive connector. The standard drive models and the SED drive models have identical hardware, however the security and encryption portion of the drive controller ASIC is enabled and functional in the SED models. This represents a small additional drain on the 5V supply of about 30mA and a commensurate increase of about 150mW in power consumption. There is no additional drain on the 12V supply.
22
Constellation SAS Product Manual, Rev. F
Table 2:
500GB drive (Standard & SED model) DC power requirements 3. 0 Gbit mode Notes (Amps) +5V [5] [1] [7] ±5% 0. 33 (Amps) +12V [4] ±5% [2] 0. 10 6. 0 Gbit mode (Amps) +5V ±5% 0. 34 (Amps) +12V [4] ±5% [2] 0. 10
Voltage Regulation Avg idle current DCX Advanced idle current Idle_A Idle_B Idle_C/ Standby_Y Standby_Z Maximum starting current (peak DC) DC (peak AC) AC Delayed motor start (max) DC Peak operating current (random read): Typical DCX Maximum DC Maximum (peak) DC Peak operating current (random write) Typical DCX Maximum DC Maximum (peak) DC Peak operating current (sequential read) Typical DCX Maximum DC Maximum (peak) DC Peak operating current (sequential write) Typical DCX Maximum DC Maximum (peak) DC 3 3 3 3 3 3 3 3 [1] [6] [1] 3 3 3 [5] [5] [1] [6]
0. 32 0. 23 0. 23 0. 23
0. 10 0. 08 0. 05 0. 02
0. 34 0. 24 0. 24 0. 25
0. 10 0. 08 0. 05 0. 02
0. 59 0. 90 0. 55
0. 65 0. 87 0. 03
0. 60 0. 97 0. 58
0. 65 1. 03 0. 03
0. 41 0. 44 0. 98
0. 14 0. 15 0. 54
0. 43 0. 46 1. 04
0. 14 0. 14 0. 54
0. 46 0. 49 1. 22
0. 14 0. 14 0. 56
0. 47 0. 50 1. 22
0. 14 0. 14 0. 56
0. 73 0. 77 1. 04
0. 12 0. 12 0. 20
0. 75 0. 80 1. 12
0. 12 0. 12 0. 20
0. 79 0. 84 1. 20
0. 12 0. 12 0. 20
0. 80 0. 85 1. 22
0. 12 0. 12 0. 20
[1] [2] [3] [4]
Measured with average reading DC ammeter. Instantaneous +12V current peaks will exceed these values. N (number of drives tested) = 6, 35 Degrees C ambient. For +12 V, a 10% tolerance is allowed during initial spindle start but must return to ±5% before reaching 7, 200 RPM. The ±5% must be maintained after the drive signifies that its power-up sequence has been completed and that the drive is able to accept selection by the host initiator.
Constellation SAS Product Manual, Rev. F
23
[5] [6] [7] [8] [9]
See +12V current profile in Figure 1. This condition occurs after OOB and Speed Negotiation completes but before the drive has received the Notify Spinup primitive. See paragraph 7. 3. 1, "Conducted noise immunity. " Specified voltage tolerance includes ripple, noise, and transient response. Operating condition is defined as random 8 block reads. During idle, the drive heads are relocated every 60 seconds to a random location within the band from three-quarters to maximum track.
General DC power requirement notes. Minimum current loading for each supply voltage is not less than 1. 7% of the maximum operating current shown. The +5V and +12V supplies should employ separate ground returns. Where power is provided to multiple drives from a common supply, careful consideration for individual drive power requirements should be noted. Where multiple units are powered on simultaneously, the peak starting current must be available to each device. Parameters, other than spindle start, are measured after a 10-minute warm up. [. . . ] Table 12: Ready LED Out conditions
LED status 0 Off On On Off 1 Off On Off On
Normal command activity
Ready LED Meaning bit mode page 19h
Spun down and no activity Spun down and activity (command executing) Spun up and no activity Spun up and activity (command executing) Spinning up or down Format in progress, each cylinder change
Blinks steadily (50% on and 50% off, 0. 5 seconds on and off for 0. 5 seconds) Toggles on/off
Constellation SAS Product Manual, Rev. F
59
The Ready LED Out signal is designed to pull down the cathode of an LED. The anode is attached to the proper +3. 3 volt supply through an appropriate current limiting resistor. The LED and the current limiting resistor are external to the drive. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SEAGATE ST9500432SS
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.