Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SEKONIC L-308BII FLASHMATE. We hope that this SEKONIC L-308BII FLASHMATE user guide will be useful to you.
Lastmanuals help download the user guide SEKONIC L-308BII FLASHMATE.
Manual abstract: user guide SEKONIC L-308BII FLASHMATE
Detailed instructions for use are in the User's Guide.
[. . . ] 3. 2 How to fit the Lumidisc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3. 3 How to remove the Lumidisc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.
Light-receiving Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4. 1 Incident light metering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5. Preparation for Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5. 1 5. 2 5. 3 5. 4 5. 5 5. 6 5. 7 Inserting the battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Otherwise, the Lumidisc will affect the exposure in proper reading.
4. 2 Reflected light metering
You can meter the reflected light of the object by pointing the L-308Bll's lens at the object from the camera's position. 9 Caution: If you measure from the camera position, the entire object is measured in average. If you want to measure only a part of the object, do it at as close a position as possible to the part measured. Take care so that the part measured may not be shadowed by the meter, etc.
4
5. Preparation for Measurement
5. 1 Inserting the battery
Use a 1. 5-volt, type-AA battery. Use a manganese dry cell (R6P) or an alkaline one (LR6). 0 To remove the battery case cover simply slide it in the direction of the arrow. 0 Insert the battery in the battery case aligning the polarities as indicated on the inside of the case. 10) 8 Slide the battery case cover along the unit to close it. Check that the cover is securely closed.
5. 2 Battery check
Depress the POWER button, and the LCD panel ("b. c" message and bar marking $`i) displays the current battery level. The battery level is indicated by a number of bars for one second. Then, the LCD panel automatically switches to the normal measurement mode. piii?iq
NOTES
l l
You can sustain battery level display by holding down the Power button. When the battery level is indicated by only two or three dots, prepare a new battery. When the battery capacity drops below the limit, the "b. c" display blinks and then disappears.
5. 3 Auto Power-off
To save battery capacity, the L-308Bll is automatically turned off (and all readings are erased) 4 minutes after your last operation.
Press the mode selection button to select the desired measurement mode. Mode switching sequence:
a Measurement mode Measurement mode with cord -
---II Measurement mode without cord
5
NOTE
0 If you press the mode selector in the ambient light measurement mode while holding down the IS0 button, the display is toggled between EV and F values (Fig. If it is toggled after measurement, the measurement data is automatically recalculated and redisplayed.
Fig. 13
5. 5
Setting up film speed (ISO)
0 Press the IS0 button, and a film speed value is displayed (Fig. @ Set up the film speed by pressing the Up or Down button while holding down the IS0 button. 14 button, the speed increases; if you press the Down button it decreases. If you hold down the Up/Down button for more than one second, the speed changes continuously. NOTE
l
You can set up the film speed either before or after measurement.
5. 6
Setting up shutter speed (T)
Set up the shutter speed used by pressing the Up or Down button (Fig, 15). [. . . ] EV to lx conversion table
(Example) If you read EV9 $1 _, the approx. illuminance value is 1800lx.
10
10. Specifications
Type Light-receiving method Light-receiving section Digital exposure meter for ambient and flash metering Incident and reflected light metering system l Incident light: Lumisphere, Lumidisc l Reflected light: Lens (light receiving angle of 40°) Light receiving element l Silicon photo diode 0 Ambient light: Shutter speed-priority metering Metering systems l Flash light: With synchro cord Without synchro cord l Ambient light: EVO to EV19. 9 (at 0. 1 EV step) Measuring range F1. 4 to F90 + 0. 9 stop (at 0. 1 AV step) (IS0 100) * Flash: kO. 1 EV or less Repeat accuracy Calibration constant l Incident light metering: C = 340 (lumisphere), C = 250 (lumidisc) * Reflected light metering: K = 12. 5 l IS0 (film speed): 3 to 8000 (at 1/3 SV step) Display range l T (shutter speed): Ambient light: 60 sec to 1/8000 sec (at 1 TV step) f/s (frames/sec): 8, 12, 16, 18, 24, 25, 30, 32, 64, 128 Opening angle: 180 degrees Flash: 1 sec to 1/500 sec (at 1 TV step), and 1/75, 1/80, 1/90, 1/100 l Aperture: 0. 5 to 90. 9 (at 0. 1 AV step) * EV (Exposure Value): -5 to 26. 2 l Out-of-range metering: Other function "E. u" (underexposure) or "E. 0" (overexposure) warning indication l Battery check l Auto power-off * A single type-AA battery (Alkaline or manganese), 1. 5V Battery used Operating temperature l 0°C to +4O°C range Storage temperature . -20°C to +60°C range Dimensions l Approx. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SEKONIC L-308BII FLASHMATE
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SEKONIC L-308BII FLASHMATE will begin.