[. . . ] The Studio Deluxe is the answer to this problem. Optimum exposure meter for incident light measuring method (also applicable for reflected light method. ) 2. Freely rotatable light sensor section for very easily performed measurements. Meter stopper mechanism allows operation while hand is released from meter. [. . . ] STANDARD ACCESSORY OPERATION
Incident Light Measurement 1. To mount, align white dots of Lumisphere frame and light sensor, then turn Lumisphere carefully clockwise (approx. Set film sensitivity knob @0 to sensitivity value of employed film. Set ISO value to right side ISO mark !1. Photo shows setting for ISO 100.
ISO
200 100 50
24
4 8 18 2
12 0 60
64
c. From position where subject is to be measured, point Lumisphere q in direction of camera. (Light sensor w can be turned freely. )
8
250 8 C I N E 5 k1 2. 8 00 1k 2k 4k 8
12
5
2
60 3 0
15 8 4
90 6
21
4
6. Hold meter erect and press stopper button !3. Meter needle !8 deflects according to brightness. When the stopper button is released, the meter needle becomes fixed at the deflected position. If the location is excessively bright and the meter needle deflects beyond scale, insert the High slide @2.
ISO
5 10 20
2
-2
ISO
5 81 24 0 12 8 15 30 6 64 18
8 24
45 32 22 16 1
250
12
64
8C INE
200 100 50
EC
-1
13
1/S 5 5. 6 00 1k 2k 4k 8k F 4 2. 8 0. 7 2 1. 4 1
0 56 40 4 8 2 0 28 Deluxe Studio 5 10 2 0 320 640 1. 25 . 4 11 80 16 2 -2 -1 k + +1 0 H +1 14 EV
4
NE
200 100 50
1/S 2k 4k 8k
e. Read the footcandle scale e of the meter needle. Transfer footcandle value to the dial scale u. Rotate the dial ring !6 and set the scale mark i. If the High slide @2 has been inserted, set the H mark o.
160 80 56 40 4 2 0 28 Deluxe Studio 5 10 2 20 40 . 4 5 10 11 -2 -1 +1 +2
L-398A
320 8
80
0
640 11 1. 2
16
5k
16 0 H 2 2 Deluxe Studio 5 10 2 20 40 . 4 80 5 10 11 -2 -1 16 0 +1 +2
H
0
40 11 1. 2
16
5k
EC
-1
8
9 EV
+1
. 2 40 1 06 32
-2
128
90 64
0
+2
7
60 30
15
60 30
640 11 1. 2
16
5k
5k
15 8 4
21
128
90
9
6. At this time, the shutter speed scale !4 and aperture scale !5 combination becomes the correct exposure. Example:With High slide inserted, meter indicates 80 footcancles. At ISO 100, the proper exposure becomes 1/250 sec at F/ 5. 6, 1/30 sec at F/16 and 1 sec at F/90. By changing ISO setting, the set combination of shutter speed and aperture scale is automatically altered to the appropriate one corresponding to the changed ISO value. Meter scale intermediate values
Footcandles
125 100
250 200
64 50
50 400 0
4
12 16 8 6
80 40 4 2 0 28 5 10 2 2. 8 2 . 4 11
25
160 56
320 8
80 1k 0
0
640 11 1. 2
16
5k
1. 6 k 2k
2 25 2 20
15
2
8 10
25 50 100 200 50 2 30 60 125
0 80 1k 400500
16 18 14
11 8 13 10 9
7. 1
5. 6 6. 4
. 2 2. 8 2 4 3. 2 2. 5 4. 5 3. 6
5
10k 8k
5k 4k
Film sensitivity intermediate values ISO
80 64
3 25020
64 50 0 0
40 0
160 125
200
100
50
25
40 32
20 16
12
8
6
10
10
1. 6 1. 4
1. 8
1. 3 1. 1
0. 8
Intermediate values for Shutter speed and aperture scale
8k 1/SEC
5 4 2 32 28 1 42 6 45 40 3 64 50 128 90 56 112 110 80 72
4k
1
2. 5k 2k
0. 9
1. 6k k 1. 2 1k 800
6. 4k
0. 7F
3. 2k
12k
6. STANDARD ACCESSORY OPERATION
2. Lumidisc
Employ for illumination contrast adjustment and illuminance measurement.
· Contrast measurement
a. Install in the same manner as Lumisphere. [. . . ] Optional Accessories Operation
2. Direct Reading Slide Application
When photographing, select slide from the above table according to film sensitivity and shutter speed. Insert slide and perform measurement in the same manner as for incident light. Read directly the aperture value r indicated by the meter needle !8. Since it is not necessary to rotate the dial when employing direct reading slides, setting becomes extremely fast and convenient.
17
8. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SEKONIC L-398A
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.