User manual SEKONIC L-608 CINE SUPER ZOOM MASTER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SEKONIC L-608 CINE SUPER ZOOM MASTER. We hope that this SEKONIC L-608 CINE SUPER ZOOM MASTER user guide will be useful to you.

Lastmanuals help download the user guide SEKONIC L-608 CINE SUPER ZOOM MASTER.


Mode d'emploi SEKONIC L-608 CINE SUPER ZOOM MASTER
Download
Manual abstract: user guide SEKONIC L-608 CINE SUPER ZOOM MASTER

Detailed instructions for use are in the User's Guide.

[. . . ] Super Zoom Master L-608/L-608 Operating Manual Blank page Congratulations on your purchase of a Sekonic Super Zoom Master L-608/L-608CINE Exposure Meter. The Super Zoom Master L-608/L-608CINE is the latest addition to the extensive line of Sekonic Exposure Meters which have been market leaders. It was designed to be the ultimate meter, a do-all instrument for the most demanding pros. It is the first zoom spot meter with digital spot viewfinder readout on the market. Nine camera-quality lens elements are required to accomplish its 1° to 4° zoom range. [. . . ] When the Measuring button !5 is pressed, the mode mark will blink and the meter is ready to measure. The ready to measure mode will continue for approximately 90 seconds. During this time, trigger the flash to make a measurement. 4. If the 90 second period is exceeded and the blinking mark stops, press the Measuring button again to return to ready to measure. Set shutter speed Perecentage of flash in total exposure 5. When the light from the flash is received, the measured value (f stop) is displayed. Even after continues to blink measurement, the mode mark and the meter is in ready state and a new measurement can be made. (Auto-reset function) Measured f stop value 1/10 f stop Ambient Flash Measured f stop (total exposure) NOTES: · When firing a flash, if the flash brightness is low compared to the ambient light, the meter may fail to detect the light. In this case, make measurements using the cord flash mode. · Rapid start fluorescent lamps and special lighting are sometimes mistaken for flash, and accidentally measured. In this case, make measurements using the cord flash mode. · The meter's tripod socket permits mounting it to a tripod or light stand and placing it strategically when using cordless flash mode. Reference: · After measurement, the F stop value corresponding to the shutter speed is displayed when the shutter speed is changed. · Setting the shutter speed is similar to the previous instruction. (see page 18) of "Cord flash mode" of section 2-1. · A new converted value is displayed when the film speed is changed after taking the measurement. · Readings outside the display range or beyond the measuring range are similar to the previous instruction. (see page 19) of "Cord Flash mode" of section 2-1. -20- 5. Measurement 2-3 Cord multiple flash (cumulative) mode These measurements are used when the light generated by the flash is inadequate for proper exposure. The repeated flash pops can be accumulated until the desired aperture is displayed. Only one digit is displayed if the cumulative number is ten or more. Display returns 0 (0=10, 1=11, 2=12, etc. ) 1. Slide DIP switch 2 to MULTI (see page 9) to the ON position. Hold down the Mode set button !0 and turn the Jog wheel t to select cord multiple flash (cumu. [. . . ] · If you are operating the exposure meter in areas under wet conditions or high humidity, keep the sync post covered. If you are using flash in these conditions, Cordless Flash mode is recommended. -43- 10. Care and Maintainance NOTE: · Although this meter has an All-weather design for everyday use (JIS standard water resistance class 4), do not place it in water or use it underwater. This will cause it to malfunction. Splashed Do not wash with water Rain Do not submerge or use under water · To avoid damaging this meter, never drop it or subject it to shock. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SEKONIC L-608 CINE SUPER ZOOM MASTER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SEKONIC L-608 CINE SUPER ZOOM MASTER will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag