Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SENNHEISER EM 3732-II. We hope that this SENNHEISER EM 3732-II user guide will be useful to you.
Lastmanuals help download the user guide SENNHEISER EM 3732-II.
You may also download the following manuals related to this product:
SENNHEISER EM 3732-II 09-09 (7701 ko)
SENNHEISER EM 3732-II DATASHEET (231 ko)
SENNHEISER EM 3732-II ANNEXE 256 (7701 ko)
SENNHEISER EM 3732-II PRODUCT SHEET (231 ko)
SENNHEISER EM 3732-II FREQUENCY SHEET (570 ko)
SENNHEISER EM 3732-II FREQUENCY TABLES (570 ko)
Manual abstract: user guide SENNHEISER EM 3732-II
Detailed instructions for use are in the User's Guide.
[. . . ] EM 3731-II EM 3732-II EM 3732-II Command
Instruction manual
Contents
Contents
Important safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 The product family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 The frequency bank system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Delivery includes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The position of a menu within the operating menu is illustrated by a graphic in the upper display margin (the "Tune" menu is on the very left of the operating menu). 000 MHz
Tune
B. Ch
1. 01
Bank
Turn the jog dial 7 until the icon of the desired menu is in the center of the display. Press the jog dial 7 to get into the setting mode of the selected menu. The icon of the menu is displayed and the current setting starts flashing. In addition, the green backlighting of the save button 8 flashes. Adjusting a setting
B. Ch
U. 01
776
UHF
776. 000
960
MHz
MHz
B. Ch
U. 01
776
UHF
777. 225
Turn the jog dial 7 until the desired setting appears. Press the jog dial 7 to confirm the selected setting. Depending on the selected menu, the next setting that can be changed and confirmed by turning and pressing the jog dial 7 flashes. Storing a setting Press the save button 8 to store the setting. An animation appears on the display, indicating that the setting has been stored. The display then changes to the selection mode of the operating menu. Exiting the operating menu/cancelling an entry You can exit the operating menu or cancel an entry at any time.
960
MHz
MHz
6. 000 . 01BANK CH
M H z
HD P
save
AF COM
clock
esc
sync
Press the esc button 6. The display then returns to the previous menu level. To return to status display, you may have to press the esc button 6 several times in succession.
6
24
Using the operating menu
Overview of the menus
Selection mode
A
Setting mode
AF COM
RF
300 100 30
B
PEAK 100 50 10
% DEV
µV
10
776. 000 01. 01 BANK CH
M H z
HD P
esc
B. Ch
776. 000 MHz
Tune
B. Ch
1. 01
Bank
U. 01
776
UHF
776. 000
MHz
B. Ch
U. 01
776
UHF
866
MHz
777. 000
MHz
866
MHz
Receiving frequency
Adjusting the receiving frequency (first three digits)
save
Adjusting the receiving frequency (last three digits)
77. 05 MHz
une
B. Ch
B. Ch
B. Ch
1. 01
Bank. Ch
CEL
Nam
777. 005MHz
1.
848. 225MHz
5. 16
Frequency bank and channel
Current frequency bank and channel
save
+, -|/0123456 789*;<=> AB CDEFGHIJKLMN OPQRSTUVWXYZ
Adjusting the frequency bank (1. . . 6, U) and the channel (1. . . 60)
. Ch
. 16
B. Ch
CEL
Name
30
Squel
CE
+, -|/0123456 789*;<=> AB CDEFGHIJKLMN OPQRSTUVWXYZ
Name
Current name
Entering the name
save
300
EL
ame
30
50
50
30 µV
µV
30 10 3
300
30
10 µV
µV
30 10 3
10
Squelch
Booste Squel
Squelch
Current squelch threshold
Adjusting the squelch threshold
save
30
uelch
Booster
+12 AF O
Booster Feed On
Booster Feed Off
Booster supply voltage
Current setting of the booster supply voltage
Switching the booster supply voltage on/off
save
ooster
+12 AF Out
48 Clock
25
Using the operating menu
Selection mode
30
quelch quelch Booster
Setting mode
+12 AF O
+12 dB
ooster +12 AF Out 48 Clock +12
+18 dB
+18
Audio output level
Current audio output level
Adjusting the audio output level (-10 dB to +18 dB)
save
3
18 F Out 48 20 Clock Comm 44. 1 48 kHz 88. 2 96 Ext. 44. 1 48 kHz 88. 2 96 Ext.
48
96
Sampling rate of the digital audio signal
Current sampling rate
Adjusting the sampling rate (44. 1, 48, 88. 2, 96, Ext)
save
3
AF COM COM AF AF COM
3
96 lock
3
1
Command Comm More
Audio outputs of the receiver
Current setting of the audio outputs
Adjusting the main output "AF"/command output "COM"
save
3
mmand More
HiD plu
Changing to the extended menu
esc
Scan
Comp
26
Using the operating menu
Selection mode
Setting mode
mmand
More
esc
HiD plu
Scan
Comp
Channel list Scan new Scan reset
Bank Free Bank Free
123 43 40 42 456U 32 31 33 60
Scanning the frequency banks for free channels
Displaying the list of free channels
Displaying the last scan result
Channel list Scan new Scan reset
Bank Free Bank Free
123 43 40 42 456U 32 31 33 60
Starting the scan
Displaying the new scan result
Channel list Scan new Scan reset
Bank Free Bank Free
123 43 40 42 456U 32 31 33 60
Releasing channels marked with "Freq. occupied"
Number of "free" channels is reset to the maximum
B. Ch
776. 225MHz
3. 01
save*
Bank Free Bank Free
123 43 40 42 456U 32 31 33 60
Selecting a channel
Selecting a frequency bank
HiDyn plus
4
HiDynplus HDX
HiDyn plus
HiDynplus HDX
HiDyn plus
can
Compander
Disp
Compander system
Current compander system
Selecting the compander system
save
Dyn us
4
10 49 68 75
pander
Display
IP-Ad
* After pressing the save button 8, the display automatically changes to the "Bank. Ch" menu (see page 25) i. e. [. . . ] 200 mA each, short-circuit proof, switchable IEEE 802. 3-2002, shielded RJ 45 socket with optional locking facility AES3-2003, XLR-3, 44. 1, 48, 88. 2 or 96 kHz SR, 24 bits, externally synchronizable 2 BNC sockets (75 ), daisy chain output 44. 1 kHz, 48 kHz, 88. 2 kHz, 96 kHz 75 , transformer balanced, AC-coupled input voltage range 200 mV . . . input voltage 15 V (DC + AC) 75 , transformer balanced, AC-coupled output voltage 2. 5 V± 250 mV at 75 source impedance
Mains connector Dimensions W x D x H [mm] Weight Booster supply Ethernet Digital output Word clock connection Accepted sampling rates Word clock input
Word clock output
Operating conditions Ambient temperature Relative humidity Power supply Protection against dripping and splashing Storage and transport conditions Ambient temperature Relative humidity Protection against dripping and splashing Shock test 25°C to +70°C max. 90% at 40°C the product must not be exposed to dripping and splashing (IP 20) shock test according to IEC 68 or EN 60068, T2-27 10°C to +55°C max. 85% at 40°C (non condensing) 100 to 240 V~, 50/60 Hz the product must not be exposed to dripping and splashing (IP 20)
In compliance with Europe EMC Radio Safety 47 CFR 15
Industry Canada
USA Approved by
EN 301489-1/-9 EN 300422-1/-2 EN 60065 subpart B
RSS-123, IC: 2099A-EM373X2
46
Manufacturer Declarations
Manufacturer Declarations
Warranty Sennheiser electronic GmbH & Co. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SENNHEISER EM 3732-II
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SENNHEISER EM 3732-II will begin.