Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SENNHEISER NET 1. We hope that this SENNHEISER NET 1 user guide will be useful to you.
Lastmanuals help download the user guide SENNHEISER NET 1.
You may also download the following manuals related to this product:
SENNHEISER NET 1 PRODUCT SHEET (82 ko)
Manual abstract: user guide SENNHEISER NET 1
Detailed instructions for use are in the User's Guide.
[. . . ] Instructions for use
NET 1
Contents
Important safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Important safety information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Accompanying documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
The NET 1 network system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] If all frequencies have been successfully transferred to the transmitters (IEM), the yellow "DATA LINK" LED flashes slowly. Note:
º
If you have connected more rack-mount transmitters (IEM) from one frequency range than free channels are available in one channel bank, switch off the surplus transmitters.
19
Transferring frequencies to the portable receivers (IEM) On the NET 1, press the channel button ¾ corresponding to the transmitter (IEM) whose frequency you want to transfer. For data transfer, open the cover of the portable receiver (IEM) to be configured. Place the receiver (IEM) in front of the infrared interface ³. The distance between the infrared interface of the NET 1 and the infrared interface of the receiver (IEM) must not exceed 10 cm. The yellow "DATA LINK" LED flashes slowly. The corresponding "CHANNEL" LED · flashes rapidly until the frequency transfer is completed. Note: You can interrupt the process by pressing the channel button ¾ corresponding to the transmitter (IEM).
< 10 cm
·
If the frequency transfer to a portable receiver (IEM) was unsuccessful, the "ERROR" LED flashes rapidly for approx. 3 seconds: Reposition the portable receiver in front of the infrared interface or select another receiver from the matching frequency range and place this transmitter in front of the infrared interface.
¾
When all the frequencies have been successfully transferred, the yellow "DATA LINK" LED lights up permanently. If necessary, repeat the above steps for the next frequency range.
º
²
Transferring frequencies to portable receivers (IEM) without a prior frequency scan With the NET 1, you can also transfer the set transmission frequency of a connected rack-mount transmitter (IEM) to the corresponding receiver (IEM) without having performed a frequency scan. To do so, proceed as described in the section "Transferring frequencies to the portable receivers (IEM)" on page 20. Cancelling the frequency scan on the NET 1 Press the MODE button . All transmitters maintain their transmission frequency. Cancelling the frequency transfer
¶
Press the MODE button
.
The frequency transfer is completely cancelled. All receivers whose frequency has not yet been changed maintain their receiving frequency.
20
Performing a frequency scan for wireless microphone systems
The NET 1 selects one rack-mount receiver from each of the frequency ranges to perform the frequency scan. The frequencies of the selected channel bank are assigned to the connected receivers of this frequency range. Subsequently, the frequencies are transferred to the corresponding portable transmitters. Note: When you have connected both monitoring and microphone systems to the NET 1, you first have to perform the frequency preset scan for the monitoring system. (see "Performing a frequency scan for wireless monitoring systems (IEM)" on page 18). Switching the transmitters on/off Switch on all rack-mount transmitters (IEM) connected to the NET 1. Switch off all portable transmitters that are to be configured via the NET 1. Performing the frequency scan
»
Press and hold the MODE button on the NET 1. [. . . ] For this reason, we recommend that the sales receipt be retained as proof of purchase. Without this proof (which is checked by the responsible Sennheiser service partner) you will not be reimbursed for any repairs that are carried out. Depending on our choice, guarantee service comprises, free of charge, the removal of material and manufacturing defects through repair or replacement of either individual parts or the entire device. operating faults, mechanical damages, incorrect operating voltage), wear and tear, force majeure and defects which were known at the time of purchase are excluded from guarantee claims. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SENNHEISER NET 1
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SENNHEISER NET 1 will begin.