[. . . ] SKP 2000
Instruction manual
Contents
Contents
Important safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 The SKP 2000 plug-on transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Areas of application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 The frequency bank system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] To do so, briefly press the ON/OFF button and proceed as described on page 10.
13
Using the plug-on transmitter
Selecting a standard display
Press the UP/DOWN button to select a standard display: Contents of the display Selectable standard display
543. 850 MHz **2000**
AF
"Frequency/Name"
P MUTE
B. Ch: 19. 31 543. 850 MHz
AF
"Channel/Frequency"
P MUTE
**2000** B. Ch: 19. 31
AF
"Name/Channel"
P MUTE
14
Using the operating menu
Using the operating menu
A special feature of the Sennheiser 2000 series is the consistent, intuitive menu structure of transmitters and receivers. As a result, adjustments to the settings can be made quickly even in stressful situations, for example on stage or during a live show or presentation.
The buttons
Button Function of the button Press the ON/OFF button · Switches the plug-on transmitter on and off ON/OFF · Cancels the entry and returns to the current standard display (ESC function) · Activates/deactivates the RF signal Press the SET button
SET
· Changes from the current standard display to the operating menu · Calls up a menu item · Enters a submenu · Stores the settings and returns to the operating menu
Press the UP/DOWN button
· Selects a standard display · Changes to the next/previous menu item · Changes the setting of a menu item
Overview of the operating menu
Main menu "Menu" Sensitivity Frequency Preset Name Auto Lock Advanced Exit Extended menu "Advanced Menu" Tune Mute Mode RF Power PhantomPower48V Pilot Tone LCD Contrast Reset Software Revision Exit
15
Using the operating menu
Display
Function of the menu item
Page
Main menu "Menu"
Sensitivity Frequency Preset Name Auto Lock Advanced Exit Adjusts the sensitivity "AF" Sets the frequency bank and the channel Enters a freely selectable name Activates/deactivates the automatic lock mode Calls up the extended menu "Advanced Menu" Exits the operating menu and returns to the current standard display 19 20 21 21 22
Extended menu "Advanced Menu"
Tune Sets the transmission frequencies for the frequency banks "U1" to "U6" Sets the frequency bank, the channel and the transmission frequency (frequency banks "U1" to "U6") Mute Mode RF Power Sets the mode for the MUTE switch ¾ Adjusts the transmission power 22
23 23 24 24 25 25 25 25
PhantomPower 48V Activates/deactivates the phantom powering Pilot Tone LCD Contrast Reset Software Revision Exit Activates/deactivates the pilot tone transmission Adjusts the contrast of the display panel Resets the settings made in the operating menu Displays the current software revision Exits the extended menu "Advanced Menu" and returns to the main menu
16
Using the operating menu
Working with the operating menu
If the lock mode is activated, you have to deactivate it In order to be able to work with the operating menu (see page 11). By way of example of the "Sensitivity" menu, this section describes how to use the operating menu.
Changing from a standard display to the operating menu
SET
Press the SET button. The current standard display is replaced by the main menu. The last selected menu item is displayed.
Selecting a menu item
Press the UP/DOWN button to change to the "Sensitivity" menu item. The current setting of the menu item is displayed:
Menu Sensitivity
12 dB
Changing and storing settings
Menu Sensitivity 12 dB
Call up "Sensitivity"
Sensitivity 12 dB
Select the desired setting
Sensitivity 36 dB
Store the setting
"Stored"
SET
Press the SET button to call up the menu item. Press the UP/DOWN button button to adjust the input sensitivity.
SET
Press the SET button to store the setting.
17
Using the operating menu
Canceling an entry
ON/OFF
Press the ON/OFF button to cancel the entry. The current standard display appears on the display panel.
To subsequently return to the last edited menu item:
SET
Press the SET button repeatedly until the last edited menu item appears.
Exiting a menu item
Change to the "Exit" menu item.
Menu Exit
SET
Confirm your selection. You return to the next higher menu level or you exit the operating menu and return to the current standard display.
To directly return to the current standard display:
ON/OFF
Press the ON/OFF button.
18
Adjusting settings via the operating menu
Adjusting settings via the operating menu
Make use of the possibility to adjust settings via the operating menu of your receiver and to transfer these settings to the plugon transmitter. For more information, refer to the instruction manual of the receiver. The relevant information is marked with the sync icon.
The main menu "Menu"
Adjusting the input sensitivity "Sensitivity"
Menu Sensitivity 12 dB
Call up "Sensitivity"
Sensitivity 12 dB
Select the desired setting
Sensitivity 36 dB
Store the setting
"Stored"
Adjustment range: 0 to 48 dB, adjustable in steps of 6 dB The audio level display "AF" always indicates the audio level, even if the plug-on transmitter is muted, e. g. allowing you to check the adjusted sensitivity before live operation.
B. Ch: 19. 31 543. 850 MHz
AF
P MUTE
Input sensitivity Effect/display adjusted. . . too high Close talking distances, speakers with loud voices or loud music passages cause overmodulation in the transmission link. The audio level display "AF" shows full deflection for the duration of the overmodulation.
19
Adjusting settings via the operating menu
Input sensitivity Effect/display adjusted. . . too low The audio level display "AF" shows full deflection only during the loudest passages. The transmission link is undermodulated. This results in a signal with high background noise.
Adjust a low input sensitivity when using condenser microphones, adjust a high input sensitivity when using dynamic microphones.
Selecting the frequency bank and the channel manually "Frequency Preset"
Menu Frequency Preset B. Ch: 18. 26
Call up "Frequency Preset"
Frequency Preset B. Ch: 18. 26 546. 550MHz
Select the frequency bank and confirm
Frequency Preset B. Ch: 19. 26 538. 475MHz
Select the channel; store the setting
"Stored"
When you are in the "Frequency Preset" menu item, the RF signal is deactivated. Overview of the frequency banks and channels: Frequency bank "1" to "20" Channels up to 64 per frequency bank up to 64 per frequency bank Type System bank: frequencies are factory-preset User bank: frequencies are freely selectable
"U1" to "U6"
When setting up multi-channel systems, please observe the following: Only the factory-preset frequencies within one frequency bank ("1" to "20") are intermodulation-free. It is vital to observe the notes on frequency selection on page 26. 20
Adjusting settings via the operating menu
Entering a name "Name"
Menu Name
Name Lichael
Name Michael
Enter a character; store the setting
Lichael
Call up "Name" Enter a character and confirm
"Stored"
Via the "Name" menu item, you can enter a freely selectable name (e. g. the name of the performer) for the plug-on transmitter. The name can be displayed on the "Frequency/Name" and "Name/Channel" standard displays (see page 14). [. . . ] 50 mW ("High") Pilot tone squelch can be switched off
Transmission frequencies
AF characteristics
Compander system AF frequency response Signal-to-noise ratio (1 mV, peak deviation) THD Max. input voltage Input impedance Adjustment range of input sensitivity Sennheiser HDX 8018, 000 Hz 120 dBA 0. 9 % 6 Vrms 6 k, balanced 48 dB, adjustable in steps of 6 dB
31
Specifications
Overall device
Temperature range Power supply Nominal voltage Power consumption: · at nominal voltage · with switched-off plug-on transmitter Operating time Dimensions Weight (incl. 210 mA (30 mW RF, w/o P48) 25 µA typ. 195 g 10 °C to + 55 °C 2 AA size batteries, 1. 5 V or BA 2015 accupack 2. 4 V
In compliance with
Europe: EMC Radio Safety EN 301489-1/-9 EN 300422-1/-2 EN 60065 EN 62311 (SAR)
Approved by
Canada: Industry Canada RSS 123 IC: 2099A-SKP2000 limited to 806 MHz USA: FCC-Part 74 FCC-ID: DMOSKP2000 limited to 698 MHz
Pin assignment of the XLR-3 socket
XLR-3 socket (female), balanced (Audio In)
2 3 1
32
Manufacturer Declarations
Manufacturer Declarations
Warranty
Sennheiser electronic GmbH & Co. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SENNHEISER SKP 2000
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SENNHEISER SKP 2000 will begin.