User manual SENNHEISER SKP 3000-U

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SENNHEISER SKP 3000-U. We hope that this SENNHEISER SKP 3000-U user guide will be useful to you.

Lastmanuals help download the user guide SENNHEISER SKP 3000-U.


Mode d'emploi SENNHEISER SKP 3000-U
Download
Manual abstract: user guide SENNHEISER SKP 3000-U

Detailed instructions for use are in the User's Guide.

[. . . ] Instructions for use SKP 3000 Thank you for choosing Sennheiser! We have designed this product to give you reliable operation over many years. Over half a century of accumulated expertise in the design and manufacture of high-quality electro-acoustic equipment have made Sennheiser a world-leading company in this field. Please take a few moments to read these instructions carefully, as we want you to enjoy your new Sennheiser product quickly and to the fullest. 34 Contents Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Remove the batteries or the accupack when the transmitter will not be used for extended periods of time. Muting the plug-on transmitter The transmitter has a MUTE µ switch that noiselessly mutes the audio signal without switching the transmitter off. The "MUTE" display appears on the display panel. µ Activating/deactivating the lock mode The lock mode prevents that the transmitter is accidentally programmed or switched off during operation (see "Activating/deactivating the lock mode ­ LOCK" on page 55). 45 The operating menu The buttons Buttons Mode ON/OFF Standard display Operating menu Setting mode SET Standard display Operating menu Setting mode / To. . . switch the transmitter on and off cancel the entry and return to the standard display cancel the entry and return to the standard display get into the operating menu get into the setting mode of the selected menu store the settings and return to the top menu level without function change to the previous menu ( ) or change to the next menu () adjust the setting of the selected menu: option ( / ) Standard display Operating menu Setting mode 46 Overview of menus Display BANK CHAN TUNE SENSIT PHANTO DISPLY NAME LOCK EXIT Function of the menu Switching between channel banks Switching between the channels in a channel bank Setting a transmission frequency for the channel bank "U" (user bank) Adjusting the sensitivity (AF) Switching the phantom powering on/off Selecting the standard display Entering a name Activating/deactivating the lock mode Exiting the operating menu and returning to the standard display 47 Working with the operating menu By way of example of the "TUNE" menu, this section describes how to use the operating menu. After switching the transmitter on, the standard display is shown on the display panel. Getting into the operating menu Press the SET button to get from the standard display into the operating menu. The last selected menu flashes on the display. Selecting a menu Press the / buttons to select a menu. Press the SET button to get into the setting mode of the selected menu. The current setting that can be adjusted flashes on the display. 48 Adjusting a setting Press the / buttons to adjust the setting. By briefly pressing the / buttons, the display jumps either forwards or backwards to the next setting. In the "CHAN", "TUNE" and "NAME" menu, the / buttons feature a "fast search" function. If you hold down a button, the display cycles continuously, allowing you to get fast and easily to your desired setting. Storing a setting Press the SET button to store the setting. "STORED" appears on the display, indicating that the setting has been stored. The display then returns to the top menu level. With most menus, new settings become effective immediately without having to be stored. An exception are the "BANK", "CHAN" and "TUNE" menus. With these menus, new settings only become effective after they have been stored ("STORED" appears on the display, indicating that the setting has been stored). Exiting the operating menu Select the "EXIT" menu to exit the operating menu and to return to the standard display. When in the operating menu, briefly pressing the ON/OFF button will cancel your entry (ESC function) and return you to the standard display with the last stored settings. 49 Operating menu of the plug-on transmitter SET EXIT BANK Changing the channel bank SET FIX 01 B. CH VAR 01 B. CH Current channel bank / : FIX (Fixed Bank) VAR (Variable Bank) SET: Stores the setting STORED CHAN Changing the channel SET VAR 03 B. CH VAR 02 / : Channel B. CH Current channel (display depends on "DISPLY" setting) 01. . . 20 SET: Stores the setting STORED TUNE Setting the frequency for channel bank "VAR" SET 530. 050 MHz 530. 875 / : Transmission MHz Current frequency on the selected channel frequency in steps of 5-kHz SET: Stores the setting STORED SENSIT Setting the sensitivity SET -10 dB Current sensitivity setting / -30 dB : 0. . . -50 dB SET: Stores the setting STORED PHANTO 50 SENSIT PHANTO Switching the phantom powering on/off Switching between the standard displays Current standard display SET PTM. For monitoring the adjusted sensitivity, the transmitter's level display for audio signal "AF" always indicates the audio level ­ even if the transmitter is muted. In order to be able to use highly sensitive directional condenser microphones, the plug-on transmitter offers a sensitivity range extended by 20 dB. The following figures are a guide to the best settings: dynamic microphones Loud music/vocals Presentations Interviews ­30 to ­20 dB ­20 to ­10 dB ­10 to 0 dB directional condenser microphones ­50 to ­40 dB ­40 to ­30 dB ­30 to ­20 dB 53 Switching the phantom powering on/off ­ PHANTO The plug-on transmitter can supply condenser microphones without internal power supply with 48 V phantom powering (P 48). [. . . ] Zur sachgemäßen Umsetzung der in den EG-Richtlinien genannten Anforderungen wurden folgende Normen herangezogen: conform to the basic requirements of EEC Directive 89/336/EEC resp. To effect correct application of the requirements stated in the EEC Directives, the following standards were consulted: sont conformes aux prescriptions fondamentales dans la Directive de la CEE 89/336/EEC or la Directive R&TTE 1999/5/EC. Pour mettre en pratique dans la règle de l'art les prescriptions des Directives de la CEE, il a été tenu compte des normes suivantes: 182 complen los requimientos básicos de la normativa de la CEE 89/ 336/EEC resp. Con il fin de realizar de forma adecuada los requirimientos referidos en las normativas de la CEE fueron consaltadas las siguientes normativas: sono conformi alla normativa 89/336/EEC resp. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SENNHEISER SKP 3000-U

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SENNHEISER SKP 3000-U will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag