Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SENNHEISER SZI 30. We hope that this SENNHEISER SZI 30 user guide will be useful to you.
Lastmanuals help download the user guide SENNHEISER SZI 30.
You may also download the following manuals related to this product:
SENNHEISER SZI 30 PRODUCT SHEET (236 ko)
Manual abstract: user guide SENNHEISER SZI 30
Detailed instructions for use are in the User's Guide.
[. . . ] 3. 5 mm mono jack Output impedance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . approx. 50 IR diodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Max. Radiating power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0. 5 W Operating voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 118 x 25 x 90 mm Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135 g
*see description on the following pages
Features Compact radiator and modulator/radiator for the carrier frequencies 2. 3 MHz and 2. 8 MHz Easy installation and precise alignment Delivery includes: SI 30: 1 x SI 30 modulator/radiator, 1 x AF connection cable, 3. 5 mm stereo jack plug to Texas connector, length 2 m, 1 x 3. 5 mm/1/4" stereo jack adaptor SZI 30: 1 x SZI 30 radiator The NT 20-1 plug-in mains unit is not included in the delivery. Please order it separately in the version you require (European, UK or USA versions available).
j j j
SI 30/SZI 30
IR Audio Transmission Technology | Modulators/Radiators
90 mm
m2 80 70 60 50 40 30 20 10 0
25 mm
118 mm
1 2 3 4 5 6 7 8 9 10 11 12 Channels
Dimensions of the SI 30 / SZI 30
Coverage area of the SI 30 / SZI 30
Recommended Accessories Plug-in mains unit NT 20-1 European version NT 20-1-120 USA version NT 20-1-UK UK version Mains unit for up to four SI 30 / SZI 30 NT 20-4 European version NT 20-4-120 USA version NT 20-4-UK UK version RF connection cable (2 x 3. 5 mm jack) KR 20-7 (7. 5 m) KR 20-015 (0. 1 m) AF extension cable (2 x Texas) KK 20-1 (1 m) KK 20-7 (7. 5 m) KK 20-015 4-way "octopus" cable (Texas) IZK 20 mounting clamp IZM 20 cluster mounting kit
j j j j j j j
Cat. 003561
SI 30/SZI 30
IR Audio Transmission Technology | Modulators/Radiators
SI 30 Modulator/Radiator The SI 30 is a miniature combination modulator/radiator. It is slim and compact but can cover areas of up to 80 m2 in mono operation. The integrated modulator uses stereo wideband modulation. When the audio signal at the SI 30 input exceeds a certain threshold value, the modulator/radiator is switched on automatically. It switches off again when there has not been an audio signal for about 2 minutes. Transmission is indicated by a green LED on the left of the front panel. The radiator of the SI 30 comprises 11 IR transmission diodes connected in series. The AF input of the SI 30 is a 3-pin Texas socket located at the back of the unit, on the left. It is an unbalanced stereo input, so you should not use long connection cables. A 2 m connection cable with 3. 5 mm stereo jack to a 3-pole Texas connector is supplied as standard. An automatic modulation control adapts to audio signals between 45 mV and 4 V. This process is effected over a period of about one minute, so that short speaking pauses do not entail a greater amplification. Problems may arise when you are working with microphones and very different signal levels. Longer breaks can lead to a strong increase in amplification. When connecting the SI 30 to headphone sockets of TV sets or similar sound sources, you should adjust the level to a medium value. With the channel selector switch, you can choose between channel 1 or 2 transmission or stereo operation. In mono operation, the integrated radiator and all connected radiators can cover a greater area. For mono transmission, choose the frequency suitable for the receiver, e. g. 1 1 2 3 4 2 3 4 The RF output for connection of additional radiators is designed as a 3. 5 mm mono jack socket. [. . . ] Such a system can consist entirely of SI 30 and SZI 30. As auxiliary radiators in combination with the SZI 1029, for covering room niches and recesses. As "island solutions" e. g. Such a system can economically be implemented using the SI 30. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SENNHEISER SZI 30
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SENNHEISER SZI 30 will begin.