User manual SHARP AF-Q60PX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SHARP AF-Q60PX. We hope that this SHARP AF-Q60PX user guide will be useful to you.

Lastmanuals help download the user guide SHARP AF-Q60PX.


Mode d'emploi SHARP AF-Q60PX
Download
Manual abstract: user guide SHARP AF-Q60PX

Detailed instructions for use are in the User's Guide.

[. . . ] Install the air conditioner to the opening dimensions shown below. Never install the unit where any of the air inlet is blocked. The air conditioner should be installed with a strong external support to minimize noise and vibration, and for the purpose of safe installation, repair, replacement and secure positioning. Avoid installing the air conditioner where it is exposed to direct sunlight. AF-A07CE, AF-A09CE AF-A12CE 36. 0~37. 0 cm (14. 2"~14. 6") 48 9. 0 . 0~4 "~19 cm 38. 5~39. 5 cm (15. 2"~15. 6") More than 20 cm(8") 57. 0 (22. 4 ~58 m . 0 c More than 20 cm(8") More than 20 cm (8") (18. 9 . 3") More than 20 cm (8") "~22 . 8") 8~20 cm(3"~8") 8~20 cm(3"~8") More than 40cm(16") Air outlet Air inlet More than 20cm(8") More than 40cm (16") Air inlet More than 20cm(8") Air outlet Air inlet Air inlet About 1cm (3/8") POWER CABLING GROUNDING WARNING : THIS APPLIANCE MUST BE GROUNDED. [. . . ] Use the 2 short gold screws (1. 2cm/0. 5") to fix it. (Fig. 5) Fig. 5 Drain tray Cabinet When drainage is necessary If water drainage is necessary in high humidity district, or if you do not like the splashing sound of the non-drain function, remove the rubber cap on the bottom of the chassis. Cut the rubber cap in cross, working from the bottom and remove the rubber pieces with a plier. (Fig. 6) A hose of an appropriate length have to be attached to the drain tray's drain outlet. (Fig. 7) Rubber cap Fig. 6 Chassis Drain tray Cabinet Fig. 7 4 (1) Install the cabinet into the installation Cabinet opening. (Fig. 8) (2) Secure the cabinet to the mounting frame using the 9 long gold screws. (Fig. 8) Gasket Fig. 8 WARNING: At this step, make sure the cabinet is inclined approximately 1cm (3/8") to the back (Fig. 9). If the cabinet is not properly inclined, the water collected in the bottom tray during operation will not drain properly and may flow into the room where the air conditioner is installed. (3) Cut the gasket to an appropriate length cabinet mounting frame incline backwards about 1cm (3/8") Fig. 9 and stuff it into the gap around the mounting frame and the unit to seal outside air. (Fig. 8) E-4 INSTALLATION INSTRUCTIONS 5 (1) Slide the chassis back into the cabinet. 10) Fig. 10 (2) Secure the chassis to the cabinet using the screw and angle removed in step 2. Push the angle into the gap between the chassis and the cabinet. Hook the angle to the slit of the cabinet, next screw it on to the chassis. 11) Angle Chassis Cabinet Slit Fig. 11 (3) Replace the front panel. Fan operates at medium speed; cooling power at medium. Fan and cooling at maximum power. NOTE FOR COOLING OPERATION When operating the air conditioner under extremely high outdoor temperature, set the air conditioner as shown in the chart at right for efficient performance. THERMOSTAT : 8, 9 or 10 SELECTOR : HIGH COOL VENTILATION : LEFT (CLOSED) position E-7 ENGLISH MODES OF OPERATION THERMOSTAT KNOB Use to adjust the desired room temperature setting. The air conditioner will automatically maintain the room temperature according to the THERMOSTAT setting. The higher the numbers, the cooler the room temperature becomes. Experiments may be needed in order to find out the most suitable setting. AUTO SWING SWITCH Use to activate automatic louver movement during LOW COOL, MED COOL and HIGH COOL. Adjust the louvers to change the direction of air flow for uniform and efficient cooling of the room. Set the AUTO SWING switch ON ( ), and the Left/Right air flow adjustment louvers will swing continuously to provide better circulation of cool air. The louvers will be stopped at the position when the switch is turned off. You can also use the switch to adjust the Left/Right air flow adjustment louvers to the desired position. Never attempt to move the Left/Right air flow adjustment louvers manually, or manually force the louver movement to stop during swing operation. The AUTO SWING switch will not activate the louvers when the SELECTOR KNOB is set to FAN. [. . . ] RE-INSTALL THE FILTER Fit the top hooks, and then hook the bottom of the air filter. Never operate the unit without installing the filter or the grille open. It may be resulted in serious damage to the unit. Air filter CLEANING OF THE FRONT PANEL, GRILLE AND CABINET To clean the front panel, grille and cabinet, wipe with a soft, dry cloth or with a cloth moistened with a mild soap. Rinse carefully by wiping with a damp cloth and dry completely. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP AF-Q60PX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP AF-Q60PX will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag