Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SHARP AF-R100CX. We hope that this SHARP AF-R100CX user guide will be useful to you.
Lastmanuals help download the user guide SHARP AF-R100CX.
You may also download the following manuals related to this product:
SHARP AF-R100CX (549 ko)
Manual abstract: user guide SHARP AF-R100CX
Detailed instructions for use are in the User's Guide.
[. . . ] AF-R100CX AF-R120CX AF-R140CX
ROOM AIR CONDITIONER
INSTALLATION AND OPERATION MANUAL
CONTENTS
PAGE
FOR YOUR PROTECTION . . . . . . . . . . . . . . . . . . . . 3 INSTALLATION INSTRUCTIONS
· CHECK WINDOW AREA . . . . . . . . . . . . . . . . . . . . . . . . · LOCATlON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . · ITEMS PACKED WITH THlS UNIT . . . . . . . . . [. . . ] Turn off lights or appliances that are not in use.
· Install your air conditioner in a shady location.
Direct sunlight on a window air conditioner increases its workload and will increase its operating cost.
· Don't let cool air escape.
Close windows and outside doors. Do not keep doors open and let hot air rush in. Improperly installed air conditioners and improperly weatherstripped doors and windows will let hot air in and the cool air out.
· Turn off air conditioner when no one is home.
Use only when necessary. The fewer hours a room air conditioner is used, the lower the operating cost.
9
OPERATION INSTRUCTIONS
PARTS NAMES
UNIT
4 7 3 8 9 2 1 11
1 2
3 4 5 6
5
6
10
12
7 8
Front panel Air inlet (Indoor side) Louvers Air outlet (Indoor side) Exhaust lever Control panel
9 10 11 12
Cabinet Air outlet (Outdoor side) Air inlet (Outdoor side) Filter (Pull the filter handle to the right to remove. ) Filter handle Power cord
CONTROL PANEL
1 2 3
HIGH COOL MED COOL LOW COOL FAN ONLY
F hr
TEMP
SELECTOR
TIMER
ON/OFF
ENERGY SAVER
POWER
ON/OFF
4
1
5
6
7
7
8
9
10 11
10
SELECTOR indicator 2 Receiver window for remote control signal 3 Display 4 SELECTOR pad 5 TIMER ON/OFF pad 6 TIMER indicator
8 9 10 11
TEMPERATURE setting pad ----Lower temp. ENERGY SAVER pad ENERGY SAVER indicator POWER ON/OFF pad POWER indicator
HOW TO OPERATEOPERATION INSTRUCTIONS COOLING OPERATION
Procedure Pad
POWER
ON/OFF
Display / Indicator
F hr
· POWER indicator and SELECTOR indicator (HIGH COOL) will light.
1
Touch POWER ON/OFF pad.
· The unit is preset at 74°F and HIGH COOL. This will show in the display when the power is first turned on.
2
To turn off the unit, touch POWER ON/OFF pad again.
POWER
ON/OFF
· POWER indicator and SELECTOR indicator will go off.
TO CHANGE TEMPERATURE SETTING
Procedure
During cooling operation Touch the TEMPERATURE setting pad to adjust the temperature setting.
· It can be set within the range of 64°F to 86°F.
---Lower ---Raise
Pad
TEMP
Display / Indicator
F hr
temp. temp.
· Display will change as you touch the pad.
The latest temperature setting will be memorized and will appear on the display the next time the unit is turned on. NOTE: In cases of power outages or when the unit is disconnected; when the power is restored or the unit is plugged in, the unit and display will return to the preset conditions of 74°F and HIGH COOL. The unit will not automatically turn back on. The user must touch POWER ON/OFF to resume operation.
11
HOW TO OPERATE
TO CHANGE FAN SPEED
Procedure
During operation Touch SELECTOR pad and select the desired fan speed.
SELECTOR
Pad
Display / Indicator
· SELECTOR indicator will light in order as you touch.
HIGH COOL
MED COOL
LOW COOL
FAN ONLY
NOTES ON FAN SPEED
HIGH COOL
Fan and cooling at maximum performance. Unit is preset to HIGH COOL when first turned on after unit is plugged in. Fan operates at medium speed; cooling power at medium. Cooling for sleeping comfort with low fan speed.
MED COOL
LOW COOL
FAN ONLY OPERATION
This setting can be used to circulate air whenever cooling is not desired. The fan will operate at medium speed.
Procedure
During operation Touch SELECTOR pad and select FAN ONLY.
Pad
Display / Indicator
· SELECTOR indicator FAN ONLY will light, and the temperature display will go off. After 5 seconds, the compressor will stop and the unit will operate in FAN ONLY mode.
SELECTOR
When the unit is turned off, the last fan speed will be stored in memory. The next time the air conditioner is used, the memorized fan speed will start automatically.
12
HOW TO OPERATE
ENERGY SAVER
During normal operation, the thermostat automatically controls cooling and the fan runs continuously. When the ENERGY SAVER is selected, the thermostat automatically controls cooling and the fan automatically stops when the compressor is not operating. (Fan will stop 30 seconds after the compressor stops. Even after the fan stops, the fan will
rotate for 2 minutes, every maximum 20 minutes, to detect room temperature. )
Procedure
During cooling operation
Pad
ENERGY SAVER
Display / Indicator
· ENERGY SAVER indicator will light.
1 2
Touch ENERGY SAVER pad.
To cancel, touch ENERGY SAVER pad again.
ENERGY SAVER
· ENERGY SAVER indicator will go off.
NOTE: ENERGY SAVER cannot be set during FAN ONLY mode operation.
TO CHANGE AIR FLOW DIRECTION
Adjust the louvers to change the direction of air flow for uniform and efficient cooling of the room.
Horizontal louvers Adjusts UP/DOWN air flow Vertical louvers Adjusts LEFT/RIGHT air flow
EXHAUST
If air in your room is stale, set the EXHAUST lever to the OPEN position. This will exhaust stale air to the outside. The EXHAUST lever should normally be kept in the CLOSED position during cooling for maximum efficiency.
EXHAUST Lever
CLOSED OPEN
13
HOW TO OPERATE
ON TIMER OPERATION
· This unit has a built-in timer that can be programmed to start the unit up to 12 hours in
advance.
· You can set the timer to start in increments of 30 minutes (0. 5 hours) up to 9. 5 hours in
advance of the start time, or in 1 hour increments from 10 to 12 hours in advance of the start time. · Set the timer when the unit is not operating. · The unit will start automatically according to your setting.
Procedure
Pad
TIMER
ON/OFF
Display / Indicator
· SELECTOR indicator and TIMER indicator will light. [. . . ] · Did you restart the unit within 3 minutes after a power failure?If the power was off for less than 3 minutes, and you restarted the air conditioner within 3 minutes, a protective device may cause the compressor to shut off, preventing cooling for about 5 minutes.
AIR CONDITIONER DOES NOT PROPERLY COOL
· Is the SELECTOR set to fan only mode?Cooling will not take place in the fan only mode. · Is the filter clogged with dust? [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP AF-R100CX
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP AF-R100CX will begin.