[. . . ] AH-AP18FMF
R22 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL
CONTENTS
· SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 · IMPORTANT SAFETY INSTRUCTIONS . . . . . 3 · ADDITIONAL NOTES ON OPERATION . . . . . 5 · TIPS ON SAVING ENERGY . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] · Lines will be indicated on the display when batteries are properly installed.
3 Reinstall
the battery cover.
Remote control cover
4 Press the RESET button using a thin stick.
NOTES:
· The battery life is approximately one year in normal use. · When you replace the batteries, always change both batteries, and make sure they are the same type. · If the remote control does not operate properly after replacing the batteries, press the RESET button using a thin stick. · If you will not be using the unit for a long time, remove the batteries from the remote control.
HOW TO USE THE REMOTE CONTROL
Point the remote control towards the unit's signal receiver window and press the desired button. The unit generates a beep when it receives the signal.
· Make sure there is no curtain or other object between the remote control and the unit. · The remote control can send signals from up to 7 metres away.
8
CAUTION
· Do not allow the signal receiver window to receive strong direct sunlight, since it can adversely affect its operation. If the signal receiver window is exposed to direct sunlight, close a curtain to block the light. · Using a fluorescent lamp with a quick starter in the same room may interfere with transmission of the signal. · The unit can be affected by signals transmitted from the remote control of a television, VCR or other equipment used in the same room. · Do not leave the remote control in direct sunlight or near a heater. Also, protect the unit and remote control from moisture and shock which can discolour or damage them.
9
BASIC OPERATION 1
Press the MODE button to select the operation mode.
AUTO COOL DRY
2
2 5 3 1 4
Press the ON/OFF button to start operation.
· The red OPERATION lamp ( unit will light. button to set the desired temperature.
AUTO/DRY MODE
The temperature can be changed in 1°C increments within the range of 2°C higher to 2°C lower from the temperature automatically determined by the air conditioner.
COOL MODE
The temperature can be set within the range of 18 to 32°C.
TIPS ABOUT AUTO MODE
In the AUTO mode, the temperature setting and mode are automatically selected according to the room temperature when the unit is turned on.
4
Press the FAN button to set the desired fan speed.
AUTO SOFT LOW HIGH
Modes and Temperature Settings
Room temp. Automatic Operation at operation start-up Mode Temperature Setting Below 24°C DRY Room Temp. at start-up 24°C-26°C COOL 24°C 26°C-28°C COOL 25°C Above 28°C COOL 26°C · In the DRY mode, the fan speed is preset to AUTO and cannot be changed.
5
To turn off the unit, press the ON/ OFF button again.
· The red OPERATION lamp ( unit will turn off. ) on the
10
ADJUSTING THE AIR FLOW DIRECTION
VERTICAL AIR FLOW DIRECTION
Press the SWING button on the remote control once. · The vertical adjustment louvre will change its angle continuously. Press the SWING button again when the vertical adjustment louvre is at the desired position. · The louvre will stop moving within the range shown in the diagram. · The adjusted position will be memorized and will be automatically set to the same position when operated the next time.
Adjustment range
The adjustment range is narrower the SWING range in order to prevent condensation from dripping.
HORIZONTAL AIR FLOW DIRECTION
Hold the horizontal adjustment louvre as shown in the diagram and adjust the air flow direction.
CAUTION
Never attempt to adjust the vertical adjustment louvres manually. · Manual adjustment of the vertical adjustment louvre can cause the unit to malfunction when the remote control is used for adjustment. · When the vertical adjustment louvre is positioned at the lowest position in the COOL or DRY mode for an extended period of time, condensation may result. Do not adjust the horizontal adjustment louvre to the extreme left or right in the COOL mode with the fan speed set to "SOFT( )" for an extended period of time. [. . . ] 3 Pull the air filters down to remove them. If the filters are dirty, wash them with warm water and a mild detergent. Dry filters in the shade before reinstalling. 1 Reinstall the filters in the original positions. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP AH-AP18FMF
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.