Manual abstract: user guide SHARP AR-150OPERATION MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] MODEL
AR-150
DIGITAL LASER COPIER OPERATION MANUAL
Page
GETTING STARTED MAKING COPIES SPECIAL FUNCTIONS SUPPLIES AND USER MAINTENANCE COPIER TROUBLE? APPENDIX OPTIONAL EQUIPMENT
3 12 19 22 28 36 39
CLASS 1 LASER PRODUCT
LASER KLASSE 1
LUOKAN 1 LASERLAITE
KLASS 1 LASERAPPARAT
VAROITUS!LAITTEEN KYTTMINEN MUULLA KUIN TSS KYTTOHJEESSA MAINITULLA TAVALLA SAATTAA ALTISTAA KYTTJN TURVALLISUUSLUOKAN 1 YLITTVLLE NKYMTTMLLE LASERSTEILYLLE. VARNING OM APPARATEN ANVNDS P ANNAT STT N I DENNA BRUKSANVISNING SPECIFICERATS, KAN ANVNDAREN UTSTTAS FR OSYNLIG LASERSTRLNING, SOM VERSKRIDER GRNSEN FR LASERKLASS 1.
Caution This product contains a low power laser device. [. . . ] Close the side cover by pressing the round projections near the side cover open button.
Turn the power switch on.
When copier is not in use
To prevent entry of dust and foreign matter, store the copier as follows. Remove the power cord and secure the copier using tape (two locations).
4
Supplies and user maintenance
27
COPIER TROUBLE?
This chapter describes misfeed removal and troubleshooting.
MISFEED REMOVAL
When the misfeed ( ) indicator blinks or blinks in the display, the copier will stop because of a misfeed. If a misfeed occurs when using the SPF, a number may appear in the display after a minus sign. This indicates the number of the originals that must be returned to the document feeder tray after a misfeed. Return the required number of originals. Then this number will disappear when copying is resumed or the clear ( ) key is pressed. When the SPF misfeeds an original sheet, the copier will stop and the SPF misfeed ( ) indicator will blink, while the misfeed ( ) indicator will remain off. For a misfeed of originals in the SPF, see page 41. Ensure that the bypass tray is open and then open the side cover while pressing the side cover open button.
5
Copier trouble?
Check the misfeed location. Remove the misfed paper following the instructions for each location in the illustration below. If blinks in the display, proceed to "A Misfeed in the paper feed area". 29)
If paper is misfed here, proceed to "B Misfeed in the fusing area". 29)
If the misfed paper is seen from this side, proceed to "C Misfeed in the transport area". 30)
If paper is misfed here, proceed to "A Misfeed in the paper feed area". 29)
28
MISFEED REMOVAL
A Misfeed in the paper feed area
Gently remove the misfed paper from the paper feed area as shown in the illustration. When blinks in the display and the misfed paper is not seen from the paper feed area, pull out the paper tray and remove the misfed paper. If the paper cannot be removed, proceed to "B Misfeed in the fusing area". Do not touch the fusing unit when removing misfed paper. Doing so may cause a burn or other injury.
Do not touch the surface of the drum (green portion) of the drum cartridge when removing the misfed paper. Doing so may damage the drum and cause smudges on copies. q If the paper has been fed through the bypass tray, do not remove the misfed paper through the bypass tray. Toner on the paper may stain the paper transport area, resulting in smudges on copies.
q
5
Copier trouble?
Close the side cover by pressing the round projections near the side cover open button. [. . . ] Carcinogenicity: In 1996 the IARC reevaluated carbon black as a Group 2B carcinogen (possible human carcinogen). This classification is given to chemicals for which there is inadequate human evidence, but sufficient animal evidence on which to base an opinion of carcinogenicity. The classification is based upon the development of lung tumors in rats receiving chronic inhalation exposures to free carbon black at levels that induce particle overload of the lung. Studies performed in animal models other than rats did not show any association between carbon black and lung tumors. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP AR-150
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.