DIGITAL LASER COPIER OPERATION MANUAL
Page
· GETTING STARTED · MAKING COPIES · SPECIAL FUNCTIONS · SUPPLIES AND USER MAINTENANCE · COPIER TROUBLE?· APPENDIX · OPTIONAL EQUIPMENT
3 12 19 22 26 33 36
00cover-1. p65
1
2/11/00, 15:54
CLASS 1 LASER PRODUCT
LASER KLASSE 1
LUOKAN 1 LASERLAITE
KLASS 1 LASERAPPARAT
VAROITUS!LAITTEEN KÄYTTÄMINEN MUULLA KUIN TÄSSÄ KÄYTTÖOHJEESSA MAINITULLA TAVALLA SAATTAA ALTISTAA KÄYTTÄJÄN TURVALLISUUSLUOKAN 1 YLITTÄVÄLLE NÄKYMÄTTÖMÄLLE LASERSÄTEILYLLE. VARNING OM APPARATEN ANVÄNDS PÅ ANNAT SÄTT ÄN I DENNA BRUKSANVISNING SPECIFICERATS, KAN ANVÄNDAREN UTSÄTTAS FÖR OSYNLIG LASERSTRÅLNING, SOM ÖVERSKRIDER GRÄNSEN FÖR LASERKLASS 1.
Caution This product contains a low power laser device. [. . . ] For a misfeed of originals in the SPF, see page 38. Ensure that the bypass tray is open and then open the side cover while pressing the side cover open button.
5
Copier trouble?
Check the misfeed location. Remove the misfed paper following the instructions for each location in the illustration below. If blinks in the display, proceed to "A Misfeed in the paper feed area". 27)
If paper is misfed here, proceed to "B Misfeed in the fusing area". 27)
If the misfed paper is seen from this side, proceed to "C Misfeed in the transport area". 28)
If paper is misfed here, proceed to "A Misfeed in the paper feed area". 27)
26
01C-5. p65 26 2/11/00, 15:57
MISFEED REMOVAL
A Misfeed in the paper feed area
Gently remove the misfed paper from the paper feed area as shown in the illustration. When blinks in the display and the misfed paper is not seen from the paper feed area, pull out the paper tray and remove the misfed paper. If the paper cannot be removed, proceed to "B Misfeed in the fusing area". Do not touch the fusing unit when removing misfed paper. Doing so may cause a burn or other injury.
G
Do not touch the photoconductive drum (green portion) when removing the misfed paper. Doing so may damage the drum and cause smudges on copies. G If the paper has been fed through the bypass tray, do not remove the misfed paper through the bypass tray. Toner on the paper may stain the paper transport area, resulting in smudges on copies.
5
Copier trouble?
Close the side cover by pressing the round projections near the side cover open button. The misfeed ( ) indicator will go out and the ready ( ) indicator will light up.
B Misfeed in the fusing area
Lower the fusing unit release lever by rotating it all the way as shown in the illustration. While you are lowering the fusing unit release lever, it will not move smoothly at a location on the way. However, be sure to lower the lever by rotating it all the way to the location where it will not rotate as shown in the right illustration.
Fusing unit release lever
27
01C-5. p65 27 2/11/00, 15:57
MISFEED REMOVAL
Gently remove the misfed paper from under the fusing unit as shown in the illustration. If the paper cannot be removed, proceed to "C Misfeed in the transport area". Do not touch the fusing unit when removing misfed paper. Doing so may cause a burn or other injury.
G
Do not touch the photoconductive drum (green portion) when removing the misfed paper. Doing so may damage the drum and cause smudges on copies. [. . . ] Carcinogenicity: In 1996 the IARC reevaluated carbon black as a Group 2B carcinogen (possible human carcinogen). This classification is given to chemicals for which there is inadequate human evidence, but sufficient animal evidence on which to base an opinion of carcinogenicity. The classification is based upon the development of lung tumors in rats receiving chronic inhalation exposures to free carbon black at levels that induce particle overload of the lung. Studies performed in animal models other than rats did not show any association between carbon black and lung tumors. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP AR-151
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.