User manual SHARP AR-162

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SHARP AR-162. We hope that this SHARP AR-162 user guide will be useful to you.

Lastmanuals help download the user guide SHARP AR-162.


Mode d'emploi SHARP AR-162
Download
Manual abstract: user guide SHARP AR-162

Detailed instructions for use are in the User's Guide.

[. . . ] MODEL AR-163 DIGITAL COPYING MACHINE OPERATION MANUAL Page · GETTING STARTED · MAKING COPIES · STATUS INDICATORS · GENERAL INFORMATION · OPTIONAL EQUIPMENT 2 13 28 35 53 CAUTIONS Follow the cautions below when using this copier. q q The fusing area is hot. Exercise care in this area when removing misfed paper. Do not look directly at the light source. Doing so may damage your eyes. q q q Place the copier on a firm, level surface. [. . . ] Stream feeding mode *0 OFF 1 ON Auto power shut-off setting 0 OFF *1 ON Border line for 2 in 1 or 4 in 1 * 0 OFF 1 ON Rotation copy 0 OFF *1 ON Auto paper select mode 0 OFF *1 ON Auto tray switching 0 OFF *1 ON Erase width adjustment 0 0 mm 1 5 mm (0 0" 1 1/4" Layout in 2 in 1 copy *1 Pattern 1 2 Pattern 2 Layout in 4 in 1 copy *1 Pattern 1 2 Pattern 2 Offset of paper output tray 0 Upper OFF, lower OFF 2 Upper ON, lower OFF q *2 2 3 60 sec. 240 min. *2 *2 3 *1 3 10 mm 1/2" 3 3 15 mm 3/4" 4 4 20 mm 1") Pattern 3 4 Pattern 4 Upper ON, lower ON Upper OFF, lower ON GENERAL INFORMATION Factory default settings are indicated with an asterisk (*). For layout in 2 in 1 copy and 4 in 1 copy, see page 61. ** In European countries, the default setting of the preheat mode is 1 ( 30 sec. ). For other programs, factory default settings in these countries are same to those shown above with an asterisk (*). If you select "0" (OFF) in a program, the corresponding function will be disabled. 5 Press the START ( q ) key. The right-hand number in the copy quantity display will be steadily lit and the entered value will be stored. User programs 6 To continue with other user programs, press the key and then repeat steps 2 to 5. To exit the user program mode, press the light ( ) key. q All the alarm indicators will go out. 37 USER PROGRAMS Settings for auditing accounts Settings of user programs No. 10 to 15 varies with the program number. For setting of all programs, first follow steps 1 to 3 in "Setting the user programs" on page 36 to select a program. Press the light ( ) key for more than 5 seconds. Enter a program number (10 to 15) using the numeric keys. Press the START ( ) key. ) Then follow the appropriate instructions for the program. Program No. 10: Auditing mode If the auditing mode is enabled, copying is limited to operators with an assigned 3-digit account number. A maximum of 20, 3-digit account numbers can be assigned. 10 is entered, the current setting (0: OFF, 1:ON) will blink on the right side of the copy quantity display. 1. Select the desired setting using the numeric keys. 0: 1: OFF ON 2. Press the START ( q ) key. The setting will be stored. 3. To continue with other user programs, press the key and enter another program number. To exit the user program mode, press the light ( ) key. GENERAL INFORMATION User programs Program No. 11 is entered, "­ ­ ­" will blink in the copy quantity display. q If the number of accounts has reached the upper limit (20), "11E" will appear in the copy quantity display. The copier will return to step 2 on page 36. 1. Enter a 3-digit account number using the numeric keys. q Any 3-digit number except "000" can be registered as an account number. 2. Press the START ( q ) key. If a number that is already registered or "000" is entered, the number will blink in the copy quantity display. 3. 4. Repeat steps 1 and 2 for other account numbers. To continue with other user programs, press the key and enter another program number. To exit the user program mode, press the light ( ) key. 38 USER PROGRAMS Program No. [. . . ] This classification is given to chemicals for which there is inadequate human evidence, but sufficient animal evidence on which to base an opinion of carcinogenicity. The classification is based upon the development of lung tumors in rats receiving chronic inhalation exposures to free carbon black at levels that induce particle overload of the lung. Studies performed in animal models other than rats did not show any association between carbon black and lung tumors. While there have been no studies to date using developer, a two-year cancer bioassay using a typical toner preparation containing carbon black (a small amount of toner is included in the developer mixture) demonstrated no association between toner exposure and tumor development in rats. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP AR-162

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP AR-162 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag