User manual SHARP AY-XP09DR-N

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SHARP AY-XP09DR-N. We hope that this SHARP AY-XP09DR-N user guide will be useful to you.

Lastmanuals help download the user guide SHARP AY-XP09DR-N.


Mode d'emploi SHARP AY-XP09DR-N
Download
Manual abstract: user guide SHARP AY-XP09DR-N

Detailed instructions for use are in the User's Guide.

[. . . ] AY-XP09DR-N OPERATION MANUAL · Uses ozone layer friendly refrigerant R410A. INDOOR UNIT OUTDOOR UNIT AY-XP09DR-N AE-X09DR-N ENGLISH SPLIT TYPE ROOM AIR CONDITIONER ENGLISH CONTENTS · PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-1 · PART NAMES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-3 · SETTING DEODORANT DUST COLLECTING FILTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-5 · USING THE REMOTE CONTROL . . . . . . . . . . . E-6 · BASIC OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Also, protect the unit and remote control from moisture and shock which can discolour or damage them. SET CURRENT CLOCK TIME There are two clock modes: 12-hour mode and 24-hour mode. Example: 5 o'clock in the afternoon Clock Display 12-hour mode 24-hour mode PM 5:00 17:00 MODE 1h 1 To set to the 12-hour mode, press the CLOCK button once in the first step. 2 3 1 To set to the 24-hour mode, press the CLOCK button twice in the first step. TIME 2 Press the set theADVANCE or REVERSE button to current time. · Keep the button pressed to advance or reverse the time display quickly. CLEAN FAN SWING SET/C 3 Press the SET/C button. indicate that the · The colon (:) blinks to clock is functioning. NOTE: · The current time cannot be set when the timer is operating. E-7 ENGLISH BASIC OPERATION 1 Press the MODE button to select the operation mode. AUTO HEAT COOL DRY 2 2 5 3 DISPLAY Press the ON/OFF button to start operation. · The red OPERATION lamp ( will light. button to set the desired temperature. · In the AUTO and DRY mode, the temperature can be changed in 1°C increments within the range of 2°C higher to 2°C lower from the temperature automatically determined by the air conditioner. · In the COOL and HEAT modes, the temperature can be set within the range of 18 to 32°C (Example: 1°C higher) 1 MODE 1h C (Example: 2°C lower) CLEAN FAN SWING SET/C 4 C 4 Press the FAN button to set the desired fan speed. AUTO SOFT LOW HIGH · In the DRY mode, the fan speed is preset to AUTO and cannot be changed. 5 To turn off the unit, press the ON/OFF button again. · The red OPERATION lamp ( will turn off. ) on the unit E-8 TIPS ABOUT AUTO MODE In the AUTO mode, the temperature setting and mode are automatically selected according to the room temperature and outdoor temperature when the unit is turned on. Modes and Temperature Settings 0 29 21 (¡C) 10 18 Cool (24¡C) Heat Heat (24¡C) (23¡C) Dry ( Room Temp. ) -2¡C Heat (22¡C) the figures in ( ) are temperature settings 28 34 temp. (¡C) outdoor Cool Cool (25¡C) (26¡C) indoor temp. During operation, if the outdoor temperature changes, the temperature settings will automatically slide as shown in the chart. TIPS ABOUT INDICATOR PANEL The indicator panel will change each time you press the DISPLAY button in the following manner. DISPLAY temperature Indiactor Room Temp. Lamp The room temperature is displayed. The outdoor temperature is displayed. temperature Indiactor Outdoor Temp. Lamp No display. NOTES: · The displayed temperatures are rough estimates and may vary from the actual temperatures. · Temperature display ranges Room temperature: 0°C ~ 40°C ( is displayed when less than 0°C and when higher than 40°C) Outdoor temperature: -9°C ~ 45°C ( is displayed when less than -9°C and when higher than 45°C) · is displayed during the first 60 seconds of operation while the temperatures are being detected. · The temperature display will go off. AM TO CANCEL Press the FULL POWER button again. · FULL POWER operation will also be cancelled when the operation mode is changed, or when the unit is turned off. DISPLAY 1 NOTE: · You can not set the temperature and fan speed during the FULL POWER operation. E-11 ONE-HOUR OFF TIMER When the ONE-HOUR OFF TIMER is set, the unit will stop operating after one hour. 1 Press the ONE-HOUR OFF TIMER button. · The remote control displays " ". · The orange TIMER lamp ( ) on the unit will light up. · The unit will stop operating after one hour. TO CANCEL Press the TIMER CANCEL (SET/C) button. MODE 1h 1 · The orange TIMER lamp ( ) on the unit will turn off. Or, turn the unit off by pressing the ON/OFF button. · The red OPERATION lamp ( ) and the orange TIMER lamp ( ) on the unit will turn off. CLEAN FAN NOTES: · The ONE-HOUR OFF TIMER operation has priority over TIMER ON and TIMER OFF operations. · When the ONE-HOUR OFF TIMER is set while the unit is not operating, the unit will operate for an hour with the formerly set condition. · If you wish to operate the unit for another hour before the ONE-HOUR OFF TIMER activates, press the ONE-HOUR OFF TIMER button again during operation. · If TIMER ON and/or TIMER OFF are set, TIMER CANCEL button cancels every setting. TIPS ABOUT PLASMACLUSTER OPERATION The Plasmacluster Ion generator inside the air conditioner will release Plasmacluster ions, which are collective mass of positive and negative ions, into the room. The Plasmacluster ions reduce airborne mold fungus. AIR CLEAN OPERATION Plasmacluster ions released into the air will reduce airborne mold fungus. ION BALANCE OPERATION Plasmacluster Ion generator Plasmacluster ions It is said that plenty of negative ions exist in places such as waterfalls or waterside in natural environment. In this operation mode, negative ions will be released in an increased rate, in order to bring the room air close to this condition. SELF CLEAN OPERATION Plasmacluster Operation will be performed with FAN or HEAT mode, in order to reduce the growth of mold fungus, and dry inside of the air conditioner unit. Utilize the operation at seasonal change over terms. [. . . ] · Condensation may form on the air outlet if the unit operates continuously in the COOL or DRY mode when humidity is over 80 percent. 20°C D. B. - WHEN POWER FAILURE OCCURS This air conditioner has a memory function to store settings when a power failure occurs. After power recovery, the unit will automatically re-start in the same settings which were active before the power failure, except for timer settings. If the timers were set before a power failure, they will need to be re-set after power recovery. In the HEAT operation, the indoor fan may not start for two to five minutes after the unit is turned on to prevent cold air from blowing out of the unit. DE-ICING FUNCTION · When ice forms on the heat exchanger in the outdoor unit during the HEAT operation, an automatic de-icer provides heat for about 5 to 10 minutes to remove the ice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP AY-XP09DR-N

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP AY-XP09DR-N will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag