User manual SHARP ER-A410/A420

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SHARP ER-A410/A420. We hope that this SHARP ER-A410/A420 user guide will be useful to you.

Lastmanuals help download the user guide SHARP ER-A410/A420.


Mode d'emploi SHARP ER-A410/A420
Download
Manual abstract: user guide SHARP ER-A410/A420

Detailed instructions for use are in the User's Guide.

[. . . ] ER-A410/A420 ELECTRONIC CASH REGISTER MODEL ER-A410 ER-A420 INSTRUCTION MANUAL The above illustration shows the model ER-A410. HYO-1, 4(SEEG)(E) 1 02. 4. 20, 6:46 PM ER-A410/A420(Hyo2, 3) 02. 4. 20 6:46 PM Page C2 CAUTION: The cash register and the remote drawer should be securely fitted to the supporting platforms to avoid instability when the drawers are open. CAUTION: The socket-outlet shall be installed near the equipment and shall be easily accessible. VORSICHT: Die Netzsteckdose muß nahe dem Gerät angebracht und leicht zugänglich sein. ATTENTION: La prise de courant murale devra être installée a proximité de l'équipement et devra être facilement accessible. [. . . ] 24 digits) : ; Example Key operation Print 2643 . 1 TEXT1 : ; 75 FOR THE MANAGER-2-A410/A420 02. 4. 20 6:49 PM Page 76 Programming of payee name (for English cheque) PGM 2 2646 You can program payee name (2 lines) for English cheque to be printed on the cheque. Up to 21 characters can be programmed per line. Procedure To keep the current setting 2646 . No. of lines (1 - 2) Character keys (max. 21 digits) : ; Example Key operation Print 2646 . 1 NAME1 : ; 76 FOR THE MANAGER-2-A410/A420 02. 4. 20 6:49 PM Page 77 Selection of X1/Z1 and X2/Z2 reports to be printed in the stacked report sequence PGM 2 2620 Your register is equipped with the stacked report printing function that enables multiple X/Z reports to be printed in sequence with only a single request. Procedure 2620 . * 1 Job no. To cancel the stacked report sequence For full reporting (non-range report) For individual reporting * 2 Start range parameter * 2 End range parameter : ; To program for another Job no. Note · Maximum 70 steps are programmable. "1 step" means the memory size used for one no-range type job no. · When Z of stacked report is initiated, X only reports will be skipped. Job code numbers to be used are as follows. *1: Job no. 00 10 13 20 24 27 29 30 31 32 40 50 60 70 80 82 Report name General Full department Full department group PLU PLU stock PLU zero sales PLU price category Transaction Total in drawer Commission sales Full clerk Full cashier Hourly sales information Daily net report PBLU report Balance report *2: Start/End range parameter Note *3 Start PLU code/End PLU code (1 through 999999) *3 Start PLU code/End PLU code (1 through 999999) *3 Start price amount/End price amount *3 Start time/End time (0 through 2330) Range report is available only in the X1 mode. *3 Start PLU code/End PLU code (1 through 9999) *3: Both range setting and full setting are allowed. Example Key operation Print 2620 . 10 : 13 : ; 77 FOR THE MANAGER-2-A410/A420 02. 4. 20 6:49 PM Page 78 Setting the time range for hourly reports You can set the time range for an hourly report. PGM 2 2619 Procedure When A through C are all zeros 2619 . * ABC ; *A: Time range To set the time range to 30 minutes (in the 24-hour system), enter 0. To set the time range to 60 minutes (in the 24-hour system), enter 1. BC: Starting time (hour = 00 to 23) Example Key operation Print 2619 . 107 ; Note To perform this setting, an hourly Z report (# 160) must be printed in advance. Programming of power saving mode Procedure 2689 PGM 2 2689 . * ABCD ; Selection: Enable Disable Entry: 0 1 1 through 254 (min. ) (999: the power save mode is inhibited. ) * Item: A BCD Entering power save mode when time is displayed. Time (min. ) to entering power save mode since no operation is made. Example Key operation Print 2689 . 0030 ; 78 FOR THE MANAGER-2-A410/A420 02. 4. 20 6:49 PM Page 79 Functional programming for the printer Procedure To program zero 2990 PGM 2 2990 . * AB ; *AB: Printing density (00 ­ 99) 00 = 80% for standard density 50 = 90% for standard density 99 = 100% for standard density Example Key operation Print 2990 . 50 ; Programming for EURO change job Functional programming Procedure To program zero 2681 PGM 2 2681 2682 2683 . * ABC ; Selection: Yes No Compulsory Non-compulsory Raising to unit Round off (4 - down, 5 - up) Entry: 0 1 0 1 0 1 * Item: A Automatic conversion of unit prices into EURO B C The EURO change job at programmed date/time (#2682, 2683) Fractional treatment of Exchange 1 Example Key operation Print 2681 . 010 ; 79 FOR THE MANAGER-2-A410/A420 02. 4. 20 6:49 PM Page 80 Date/time of EURO change Procedure To program zero 2682 . Date (7 or 8 digits) ; Print Example Key operation 2682 . 26112003 ; Procedure To program zero 2683 . Time (Hour: 0 - 23) ; Print Example Key operation 2683 . 23 ; 80 FOR THE MANAGER-2-A410/A420 02. 4. 20 6:49 PM Page 81 RS-232C channel assignment PGM 2 2690 Your register is equipped with two RS-232C interfaces. If you use the on-line communication function, the channel number of each RS-232C interface must be programmed by using the following procedure. To activate the on-line communication, consult your dealer. Procedure To program zero 2690 . ** P (1 - 3) *ABCD : ; Entry: 0 1 2 0 0 0 ** P: 1 * Item: A Channel no. for the ON-LINE communication Selection: Not connected Standard channel 1 Standard channel 2 B C D Always enter 0. [. . . ] (Reserved) Data backup send success Data backup receive success Data backup communication error Backup data format error Data backup time out error (Reserved) EURO change compulsory In default of programming INH. UNIT PR NOT NON-TEND BUFFER FULL EFT ERROR EFT BREAK CLOSE DRAWER ENTR SECRET# SEND OK RECEIVE OK COM. ERROR DATA ERROR TIME OUT EURO CHANGE 165 MAINTENANCE-A410/A420 02. 4. 20 6:51 PM Page 166 LIST OF OPTIONS For your register, the following options are available. ·Remote drawer model ER-03/04/05/06DW ·Key kit models By using the following key kits, you can change the keyboard layout of your register including the expansion of the number of departments. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP ER-A410/A420

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP ER-A410/A420 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag