[. . . ] ER-A410/A420
ELECTRONIC CASH REGISTER
MODEL
ER-A410 ER-A420
INSTRUCTION MANUAL
The above illustration shows the model ER-A410.
HYO-1, 4(SEEG)(E)
1
02. 4. 20, 6:46 PM
ER-A410/A420(Hyo2, 3)
02. 4. 20 6:46 PM
Page C2
CAUTION: The cash register and the remote drawer should be securely fitted to the supporting platforms to avoid instability when the drawers are open. CAUTION: The socket-outlet shall be installed near the equipment and shall be easily accessible. VORSICHT: Die Netzsteckdose muß nahe dem Gerät angebracht und leicht zugänglich sein. ATTENTION: La prise de courant murale devra être installée a proximité de l'équipement et devra être facilement accessible. [. . . ] 24 digits)
:
;
Example
Key operation
Print
2643 . 1 TEXT1 :
;
75
FOR THE MANAGER-2-A410/A420
02. 4. 20 6:49 PM
Page 76
Programming of payee name (for English cheque)
PGM 2
2646
You can program payee name (2 lines) for English cheque to be printed on the cheque. Up to 21 characters can be programmed per line.
Procedure
To keep the current setting 2646
.
No. of lines (1 - 2)
Character keys (max. 21 digits)
:
;
Example
Key operation
Print
2646 . 1 NAME1 :
;
76
FOR THE MANAGER-2-A410/A420
02. 4. 20 6:49 PM
Page 77
Selection of X1/Z1 and X2/Z2 reports to be printed in the stacked report sequence PGM 2 2620
Your register is equipped with the stacked report printing function that enables multiple X/Z reports to be printed in sequence with only a single request.
Procedure
2620
.
* 1 Job no.
To cancel the stacked report sequence For full reporting (non-range report) For individual reporting
* 2 Start range parameter
* 2 End range parameter
:
;
To program for another Job no.
Note
· Maximum 70 steps are programmable. "1 step" means the memory size used for one no-range type job no. · When Z of stacked report is initiated, X only reports will be skipped.
Job code numbers to be used are as follows.
*1: Job no. 00 10 13 20 24 27 29 30 31 32 40 50 60 70 80 82 Report name General Full department Full department group PLU PLU stock PLU zero sales PLU price category Transaction Total in drawer Commission sales Full clerk Full cashier Hourly sales information Daily net report PBLU report Balance report *2: Start/End range parameter Note
*3 Start PLU code/End PLU code (1 through 999999) *3 Start PLU code/End PLU code (1 through 999999) *3 Start price amount/End price amount
*3 Start time/End time (0 through 2330)
Range report is available only in the X1 mode.
*3 Start PLU code/End PLU code (1 through 9999)
*3: Both range setting and full setting are allowed.
Example
Key operation
Print
2620 . 10 : 13 :
;
77
FOR THE MANAGER-2-A410/A420
02. 4. 20 6:49 PM
Page 78
Setting the time range for hourly reports
You can set the time range for an hourly report.
PGM 2
2619
Procedure
When A through C are all zeros 2619
.
* ABC
;
*A: Time range To set the time range to 30 minutes (in the 24-hour system), enter 0. To set the time range to 60 minutes (in the 24-hour system), enter 1. BC: Starting time (hour = 00 to 23)
Example
Key operation
Print
2619 . 107 ;
Note
To perform this setting, an hourly Z report (# 160) must be printed in advance.
Programming of power saving mode
Procedure
2689
PGM 2
2689
.
* ABCD
;
Selection: Enable Disable Entry: 0 1 1 through 254 (min. ) (999: the power save mode is inhibited. )
*
Item: A BCD
Entering power save mode when time is displayed. Time (min. ) to entering power save mode since no operation is made.
Example
Key operation
Print
2689 . 0030 ;
78
FOR THE MANAGER-2-A410/A420
02. 4. 20 6:49 PM
Page 79
Functional programming for the printer
Procedure
To program zero 2990
PGM 2
2990
.
* AB
;
*AB: Printing density (00 99) 00 = 80% for standard density 50 = 90% for standard density 99 = 100% for standard density
Example
Key operation
Print
2990 . 50 ;
Programming for EURO change job
Functional programming
Procedure
To program zero 2681
PGM 2
2681
2682
2683
.
* ABC
;
Selection: Yes No Compulsory Non-compulsory Raising to unit Round off (4 - down, 5 - up) Entry: 0 1 0 1 0 1
*
Item: A Automatic conversion of unit prices into EURO B C The EURO change job at programmed date/time (#2682, 2683) Fractional treatment of Exchange 1
Example
Key operation
Print
2681 . 010 ;
79
FOR THE MANAGER-2-A410/A420
02. 4. 20 6:49 PM
Page 80
Date/time of EURO change
Procedure
To program zero 2682
.
Date (7 or 8 digits)
;
Print
Example
Key operation
2682 . 26112003 ;
Procedure
To program zero 2683
.
Time (Hour: 0 - 23)
;
Print
Example
Key operation
2683 . 23 ;
80
FOR THE MANAGER-2-A410/A420
02. 4. 20 6:49 PM
Page 81
RS-232C channel assignment
PGM 2
2690
Your register is equipped with two RS-232C interfaces. If you use the on-line communication function, the channel number of each RS-232C interface must be programmed by using the following procedure. To activate the on-line communication, consult your dealer.
Procedure
To program zero 2690
.
** P (1 - 3)
*ABCD
:
;
Entry: 0 1 2 0 0 0
** P: 1
*
Item: A
Channel no. for the ON-LINE communication
Selection: Not connected Standard channel 1 Standard channel 2
B C D
Always enter 0. [. . . ] (Reserved) Data backup send success Data backup receive success Data backup communication error Backup data format error Data backup time out error (Reserved) EURO change compulsory In default of programming INH. UNIT PR NOT NON-TEND
BUFFER FULL EFT ERROR EFT BREAK CLOSE DRAWER ENTR SECRET# SEND OK RECEIVE OK COM. ERROR DATA ERROR TIME OUT EURO CHANGE
165
MAINTENANCE-A410/A420
02. 4. 20 6:51 PM
Page 166
LIST OF OPTIONS
For your register, the following options are available. ·Remote drawer model ER-03/04/05/06DW ·Key kit models By using the following key kits, you can change the keyboard layout of your register including the expansion of the number of departments. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP ER-A410/A420
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.