Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SHARP FU-W28E. We hope that this SHARP FU-W28E user guide will be useful to you.
Lastmanuals help download the user guide SHARP FU-W28E.
You may also download the following manuals related to this product:
SHARP FU-W28E annexe 1 (10611 ko)
Manual abstract: user guide SHARP FU-W28E
Detailed instructions for use are in the User's Guide.
[. . . ] R
FU-W28E
*Plasmacluster is a trademark of Sharp Corporation.
Free standing type
NEDERLANDS
LUCHTREINIGER GEBRUIKSAANWIJZING
FRANÇAIS
PURIFICATEUR D'AIR MANUEL D'UTILISATION
DEUTSCH
LUFTREINIGER BEDIENUNGSANLEITUNG
ENGLISH
ENGLISH
AIR PURIFIER OPERATION MANUAL
Please read before operating your new Air Purifier
The air purifier draws in room air from its air intake, lets the air pass through an Active Carbon Filter (deodorization filter) and a HEPA Filter (dust collection filter) inside of the unit, then discharges the air from its air outlet. The air purifier unit repeats this process by moving its internal fan. As air passes through the HEPA filter if removes 99. 97% of dust particles (as small as 0. 3 microns. ). The Active Carbon Filter gradually absorbs odour elements as they repeatedly pass through the filter. Some odour ingredients absorbed by the filters may become separated and may be discharged through the air outlet and result in additional odour. [. . . ] The unit surface may be damaged or cracked. In addition, the sensors may malfunction as a result.
· During the operation of the product, please place the unit at least 2 m away from equipment which are subject to electrical waves such as televisions, radios or wave clocks. · Avoid a location where the sensor is exposed to direct wind. · Avoid locations where curtains, etc. , come into contact with the intake or air outlet. Curtains, etc. , may become dirty or a malfunction may occur. · Avoid locations where the unit is exposed to condensation, due to drastic temperature changes. (Use under appropriate conditions between 0 and 35°C in the room. ) · Place on a stable surface with sufficient air circulation. When placing the unit on a heavily carpeted area, it may cause the unit to vibrate slightly. · Do not install when there is generation of lampblack, such as in a kitchen, etc. The unit surface may crack or the sensor may malfunction as a result. · Leave about 60cm of space from the wall. The wall behind the air outlet may become dirty as time passes. When using the unit for extended period of time in the same location, use a vinyl sheet, etc. , to prevent the wall from becoming dirty. In addition, periodically clean the wall.
INSTALLATION GUIDELINES
FILTER GUIDELINES
· Follow the instructions in this manual for correct care and maintenance of the filters.
E-3
ENGLISH
PART NAMES
MAIN UNIT DISPLAY
POWER ON/OFF Button Plasmacluster ON/OFF Button Fan Speed Button
Fan Speed Indicator Lights
Odour Senser Plasmacluster Ion ON/OFF Indicator Light
ILLUSTRATIVE DIAGRAM
Odour Sensor Main Unit
HEPA Filter
(blue/white)
(black)
Washable Active Carbon Filter
Filter Support Front Panel
E-4
Blue : Plasmacluster ON Light off : Plasmacluster OFF
Plasmacluster Indicator Light(blue)
CLEAN - SIGN Light
The colour changes according to the air condition.
Clean Green
Slightly Impure Orange
Very Impure Red
BACK
INCLUDED
· Operation manual
Handle Air Outlet
Date Label
Power Cord
Plug
(Shape of plug depends on country. )
E-5
ENGLISH
PREPARATION
Be sure to remove the power plug from the wall outlet.
FILTER INSTALLATION
To maintain the quality of the filters, they are installed in the main unit and packed in plastic bags. Be sure to remove the filters from the plastic bags before using the unit.
1 1
Remove the filters
Front Panel
1 Remove the Front Panel.
Pull the bottom of the Front Panel.
2 Remove the Filter Support.
Up side Tabs Tabs
Pinch the two tabs and lift to remove.
3 Remove the Active Carbon Filter and HEPA Filter.
Active Carbon Filter HEPA Filter Main Unit
4 Remove the Active Carbon Filter and HEPA Filter from
the plastic bags.
Active Carbon Filter
HEPA Filter
E-6
2 2
Install the filters
Filter 1 Place the HEPA unit with within the main the tabs facing up.
Do not install the filter backwards or the unit will not operate properly.
Tab
HEPA Filter
the Active Carbon 2 Place on top of the HEPA Filter Filter.
Make sure that the tab of the HEPA Filter remains visible.
Tabs Tabs ENGLISH Up side Tabs Bottom side tabs Date Label
Active Carbon Filter
the tabs into the associated holes the main unit. 3 Insertpushbottom sidetabsofof the Filter Support Next the upside into the main unit.
Holes
4 Fix the Front Panel to the main unit.
usage start 5 Fill in the Date Label. date on the
Use the date as a guide for the Filter Replacement schedule.
Filter Support
E-7
OPERATION
MAIN UNIT OPERATION
Fan Speed Indicator Lights Plasmacluster Indicator Light Plasmacluster ON/OFF Indicator Light
Power ON/OFF Button
· Press to start operation (short beep) and stop operation (long beep) · Plasmacluster Indicator Light and Fan Speed Indicator Light turn on/off. · Unless the power cord has been unplugged, the operations starts in the previous mode it was operated in.
Fan Speed Button
· The operation mode can be switched as below.
AUTO operation
The fan speed is automatically switched (MEDIUM, LOW) depending on the amount of impurities in the air. The sensors detect the impurities for efficient air purification.
MAX operation
The unit will operate at a fan speed of MAX.
ION SHOWER operation
By continuously discharging strong airflow for 15 minutes the unit effectively removes airborne dust, pollen, mold and allergens from the air as they are drawn through the filter system. · When the operation finished, the unit will return to the AUTO operation.
MEDIUM operation
The unit will operate at a fan speed of MEDIUM.
SILENT operation
The unit will operate quietly using minimal air intake. * HIGH fan speed is an intermediate speed between MEDIUM and MAX. The sensor sensitivity setting will be saved even if the unit is unplugged.
E-9
CARE AND MAINTENANCE
To maintain optimum performance of this air purifier, please clean the unit including the sensor and filters periodically. [. . . ] · Is the odour sensor opening blocked or clogged?(In this case, clean the opening. ) (Refer to E-10) · Check to see if the Lights OFF Mode is selected. If so, then press the Plasmacluster ON/OFF Button for 3 seconds to activate the indicator lights. (Refer to E-9)
The discharged air has an aroma or odour.
The unit does not operate when cigarette smoke is in the air.
The Plasmacluster Indicator Light or the CLEAN-SIGN Light will not activate.
ERROR DISPLAY
LAMP INDICATION
The "SILENT" Fan Speed Indicator Light blinks.
REMEDY
Fan motor is disconnected or abnormal. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP FU-W28E
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP FU-W28E will begin.