[. . . ] R
FU-W53E FU-W43E
AIR PURIFIER OPERATION MANUAL LUFTREINIGER BEDIENUNGSANLEITUNG PURIFICATEUR D'AIR MANUEL D'UTILISATION LUCHTREINIGER GEBRUIKSAANWIJZING
Free standing type
*Plasmacluster is a trademark of Sharp Corporation.
NEDERLANDS
FRANÇAIS
DEUTSCH
ENGLISH
ENGLISH
Please read before operating your new Air Purifier
The air purifier draws in room air from its air intake, lets the air pass through an Active Carbon Filter (deodorization filter) and a HEPA Filter (dust collection filter) inside of the unit, then discharges the air from its air outlet. The air purifier unit repeats this process by moving its internal fan. As air passes through the HEPA filter if removes 99. 97% of dust particles (as small as 0. 3 microns. ). The Active Carbon Filter gradually absorbs odour elements as they repeatedly pass through the filter. [. . . ] · Avoid locations where the unit is exposed to condensation, due to drastic temperature changes. (Use under appropriate conditions between 0 and 35°C in the room. ) · Place on a stable surface with sufficient air circulation. When placing the unit on a heavily carpeted area, it may cause the unit to vibrate slightly. · Do not install when there is generation of lampblack, such as in a kitchen, etc. The unit surface may crack or the sensor may malfunction as a result. · Leaveabout60cmofspacefromthewall. The wall behind the air outlet may become dirty as time passes. When using the unit for extended period of time in the same location, use a vinyl sheet, etc. , to prevent the wall from becoming dirty. In addition, periodically clean the wall.
INSTALLATIONGUIDELINES
FILTERGUIDELINES
· Follow the instructions in this manual for correct care and maintenance of the filters.
E-3
ENGLISH
PARTNAMES
MAINUNITDISPLAY
Fan Speed Indicator Lights Filter Reset Indicator Light Plasmacluster ON/OFF Indicator Light Plasmacluster Ion ON/OFF Button Fan Speed Button ION SHOWER Indicator Light ION SHOWER Mode Button
ILLUSTRATIVEDIAGRAM
Date Label Odour Sensor Main Unit HEPA Filter Washable Active Carbon Filter
Filter Support Front Panel
E-4
Plasmacluster Indicator Light(Blue)
Blue : Plasmacluster ON Light off : Plasmacluster OFF
CLEAN - SIGN Light
The colour changes according to the air condition.
Clean Green
Slightly Impure Yellow
Very Impure Red
ENGLISH ENGLISH
POWER ON/OFF Button Light Control Button
ABOUTTHECLEAN-SIGN · The condition of the CLEAN-SIGN depends on the room air condition detected by the Dust and Odour Sensors when the plug is inserted into the wall outlet. · It is possible to have a green CLEAN-SIGN with impurities in the air at the time that the air purifier was just introduced to the room environment. After a while, however, the base impurity rate will be adjusted to detect room air condition correctly.
BACK
Air Outlet Handle
(FU-W53E only)
INCLUDED
· Operation manual
Dust Sensor Rating Label Air Inlet
Power Cord Plug
(Shape of plug depends on country. )
E-5
PREPARATION
Besuretoremovethepowerplugfromthewalloutlet.
FILTERINSTALLATION
To maintain the quality of the filters, they are installed in the main unit and packed in plastic bags. Be sure to remove the filters from the plastic bags before using the unit.
1
Remove the filters
Pull the Front Panel on the lower sides, and lift up.
Front Panel
1 RemovetheFrontPanel.
2 RemovetheFilterSupport.
Push in the hooks on top, then pull the Filter Support.
Filter Support
3 Remove the Washabe Active Carbon Filter (Black) and HEPA Filter (White) from the plastic bags.
HEPA Filter Active Carbon Filter
E-6
2
1
Install the filters
Place the HEPA Filter into the mainunit.
Please make sure that the HEPA Filter(blue) and the tab is placed inproperdirection.
Tab
(blue)
HEPA Filter
Do not install the filter backwards or the unit will not operate properly.
the Support's 2 2 Insert(left Filterright) into thebottom tabs and small holes in the unit, and slide the Active Carbon Filter between the HEPA Filter and the Filter Support.
Active Carbon Filter Filter Support
3
Gently push in the upper tabs (left and right) to lock in place.
Bottom tabs Upper tabs
4 Fill in the usage start date on the Date Label.
Use the date as a guide for the Filter Replacement schedule.
Date Label
5 ReplacetheFrontPanel.
Front Panel
Place the Front Panel from the obliquely upward, then mount the hooks at the bottom.
E-7
ENGLISH
OPERATION
MAINUNITOPERATION
PowerON/OFFButton
· Used to start operation (short beep) and stop operation (long beep) · Plasmacluster Indicator Light and Fan Speed Indicator Light turn on/off. · Unless the power cord is unplugged, the operation will start in the previous mode. · When stopping the operation in ION SHOWER mode, the unit will return to the prior ION SHOWER mode.
FAN Speed Indicator Lights FAN SPEED Button Plasmacluster ON/OFF Button
FANSPEEDButton
· The operation mode can be switched as below.
AUTOoperation
The fan speed is automatically switched (MEDIUM, LOW) depending on the amount of impurities in the air. The sensor sensitivity setting will be saved even if the unit is unplugged.
E-9
CAREANDMAINTENANCE
To maintain optimum performance of this air purifier, please clean the unit including the sensor and filters periodically. When cleaning the unit, be sure to unplug the power cord, and never handle the plug with wet hands. Electrical shock and/or bodily injury may occur as a result.
The Filter RESET Indicator Light will illuminate as a reminder to perform maintenance of the Filters and Sensors. The Indicator Light will turn on after approximately 720 hours of use. After performing maintenance, reset the Filter Reset Indicator. Plug the unit in, turn power ON, and press the Plasmacluster Ion ON/OFF Button for 3 seconds. Even if the Filter Indicator Light is already off, the Plasmacluster Ion ON/OFF Button should be pressed to reset the maintenance timer.
FILTER RESET INDICATOR LIGHT
MAINUNIT
Care Cycle
To prevent dirt or stains on the main unit, clean as often as necessary. If stains are allowed to remain, they may become hard to clean.
1 month
Wipewithadry, softcloth Do not use volatile fluids Donotusedetergents
For stubborn stains or dirt, use a soft cloth dampened with warm water. Benzene, paint thinner, polishing powder, etc. , may damage the surface. [. . . ] (In this case, clean the openings. ) (Refer to E-10) · Check to see if the Lights OFF Mode is selected. If so, then press the Light Control Button to activate the indicator lights. (Refer to E-9)
Theunitdoesnotoperatewhen cigarette smoke is in the air. The Plasmacluster Indicator LightortheCLEAN-SIGNLight willnotactivate.
ERRORDISPLAY
LAMPINDICATION
REMEDY
Fan motor disconnected or abnormal. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP FU-W43E
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.