User manual SHARP MD-MT290H

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SHARP MD-MT290H. We hope that this SHARP MD-MT290H user guide will be useful to you.

Lastmanuals help download the user guide SHARP MD-MT290H.


Mode d'emploi SHARP MD-MT290H
Download
Manual abstract: user guide SHARP MD-MT290H

Detailed instructions for use are in the User's Guide.

[. . . ] PORTABLE MINIDISC RECORDER MODEL Thank you for purchasing this SHARP product. For the best performance, read this manual carefully. It will guide you in operating your SHARP product. MD-MT290H OPERATION MANUAL PL U PO G W IN ER If you require any advice or assistance regarding your Sharp product, please visit our web-site www. sharp. co. uk/customersupport. Customers without Internet access may telephone 08705 274277 during office hours (or (01) 676 0648 if telephoning from Ireland). 0101 TINSE0504AWZZ 02M N AO 1 E MD-MT290H Accessories -Accessories/Optional Accessories- Remote Control x 1 Earphones x 1 Important Introduction AC Adaptor (RADPA8058AWZZ) x 1 Rechargeable Nickel-Metal Hydride battery (ADN70BT) x 1 Battery Carrying Case x 1 Connection Cable (for digital recording) x 1 Connection Cable (for analogue recording) x 1 Connection Cable (for PC analogue recording) x 1 Carrying Bag x 1 Notes: ! [. . . ] To write recorded contents on the MiniDisc Press the :OFF/HOLD button whilst in the stop mode. 1 2 28 Connect a stereo microphone to the MIC IN socket. Insert a recordable MiniDisc (page 11). 02/12/18 MD_MT290H_UK_4. fm MD-MT290H !Sound-actuated recording (Mic Synchronised recording) About pause function The unit automatically pauses when the microphone does not pick up any sound for 3 seconds or more. (Pause function does not work for approximately 10 seconds after a recording starts. ) When the microphone picks up sound again, recording starts automatically. 1 2 3 4 5 6 7 Press the REC button. Press the REC LEVEL or button to adjust the recording level. Select the recording mode (steps 5 - 9, page 17). Press the or button repeatedly to select "SYNC ON". Press the or button to select the recording start level. MIC SYNC H :Recording starts when the unit detects - 24 dB or more (the unit can start recording from quiet sounds). MIC SYNC L : Recording starts when the unit detects - 12 dB or more. - When a plug-in-power type microphone is plugged in, the portable MD will provide power for the microphone's operation. - If a different type of microphone is plugged in, it may not operate properly or it may cause the unit to malfunction. If you don't, the recording will not be made properly. " Use a microphone with a 3. 5 mm (1/8") diameter stereo mini plug. " If the unit starts recording too often from low unwanted noises, set the microphone input to "MIC SYNC L". " Recording sensitivity can be changed whilst recording. -Recording from a Microphone- Useful Features Notes: " Whilst making a mic recording, do not connect anything to the OPTICAL/LINE IN socket on the portable MD. " To use a microphone, be sure it is a plug-in-power type microphone. 6 5 4 3 2 1 8 9 Press the MENU/ENTER button. When a sound, such as person speaking, is picked up by the microphone, recording will begin automatically. 29 02/12/18 MD_MT290H_UK_4. fm MD-MT290H Recording from a Microphone (continued) !Track intervals When recording from the microphone, track numbers will be created automatically at regular intervals (default setting: approximately every 5 minutes). During a mic synchro recording, the unit pauses when a silence lasts for 3 seconds or more, and creates a track number. 5 6 Press the MENU/ENTER button. The mode will be set automatically after 7 seconds even if the MENU/ENTER button is not pressed. Track numbers will be created automatically at regular intervals. -Recording from a Microphone- Changing intervals between tracks Example: Set to "5 minutes". Useful Features 1 2 3 4 Press the MENU/ENTER button. Press the or button repeatedly to select "MARK". Press the or button. During a mic manual recording Timed auto marks will be created every 5 minutes. Track number 1 5 minutes Track number 2 5 minutes Track number 3 5 minutes Track number 4 During a mic synchro recording (No automatic track numbers are created. ) (A new track number is created every 3 minutes. ) If a silence lasts for 3 seconds or more, a timed auto mark will be created 5 minutes after the previous mark is created. : Track number which is created by the timed auto mark function. : Track number which is created when a silence lasts for 3 seconds or more during synchro recording. (A new track number is created every 5 minutes. ) (A new track number is created every 10 minutes. ) Track Track number 1 number 2 2 minutes 5 minutes Track Track number 3 number 4 1 minute 5 minutes Track number 5 The interval between marks may vary slightly compared with the actual recording time. Creating track numbers manually " Press the REC button whilst recording. " The BASS button on the remote control can also be used to add track numbers. 30 02/12/18 MD_MT290H_UK_4. fm Changing Default Settings Whilst in the stop mode . . . MD-MT290H ! [. . . ] 400 - 1, 800 rpm CLV ACIRC (Advanced Cross Interleave Reed-Solomon Code) ATRAC/ATRAC3 (Adaptive TRansform Acoustic Coding), 24-bit computed type Magnetic modulation overwrite method 44. 1 kHz (32 kHz and 48 kHz signals are converted to 44. 1 kHz, and then recorded. ) Unmeasurable (less than 0. 001 % W. peak) 48 -Specifications- 02/12/18 MD_MT290H_UK_6. fm MD-MT290H Battery life: Stereo When using the rechargeable Continuous battery (fully charged) includ- recording: ed with the unit Approx. 10 hours When using a commercially Continuous available, high capacity, "AA" recording: size (LR6), alkaline battery Approx. 8 hours Input sensitivity: Reference input level MIC H MIC L LINE 0. 25 mV 2. 5 mV 100 mV Input impedance 10 k ohms 10 k ohms 20 k ohms Earphones LINE Continuous play: Approx. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP MD-MT290H

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP MD-MT290H will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag