Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SHARP XGXV2E. We hope that this SHARP XGXV2E user guide will be useful to you.
Lastmanuals help download the user guide SHARP XGXV2E.
Manual abstract: user guide SHARP XGXV2EOPERATION MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] Shielded interface cables must be used with this equipment to maintain compliance with EMC regulations.
The equipment should be installed near an accessible socket outlet for easy disconnection.
Notice for users in the UK
MAINS PLUG WIRING INSTRUCTIONS
The mains lead of this equipment is already fitted with a mains plug which is either a non-rewireable (moulded) or a rewireable type. Should the fuse need to be replaced, a BSI or ASTA approved fuse to BS1362 marked or and of the same rating as the one removed from the plug must be used. Always refit the fuse cover after replacing the fuse on the moulded plug. Never use the plug without the fuse cover fitted. [. . . ] · After removing the protective material, immediately insert the drum cartridge in the machine. Do not allow the drum cartridge to be directly exposed to sunlight or electric light. · Do not tilt the drum cartridge or insert it in the wrong direction or orientation. This may damage the drum cartridge or cause a failure. Make sure that the colours on the new drum cartridge and the insertion label match.
Replace the developer cartridge and toner collection container, close the front cover of the machine, and turn on the power.
4
For the procedure for replacing the developer cartridge and toner collection container, see steps 6 to 8 and steps 10 to 11 of "Replacing the developer cartridge" (page 23). When replacement is finished, colour balance adjustments begin automatically. Colour balance adjustments (page 31)
34
REPLACING SUPPLIES AND MAINTENANCE
Replacing the transfer unit
When a message appears prompting you to replace the transfer unit, replace the transfer unit. The transfer unit consists of the primary transfer belt unit inside the machine and the secondary transfer roller unit under the right cover.
Replacing the primary transfer belt unit
When it is time to replace a supply item, a message instructing you to replace the item will appear in the display.
· Do not replace a supply item before the replacement message appears in the display. · Install the new primary transfer belt promptly after the primary transfer belt unit has been removed. Light entering through openings in the machine may damage the drum cartridges.
Press the [POWER] key ( ) on the operation panel to turn off the panel power, and then switch the main power switch to the off position.
1
Caution
After the main power is turned off, the primary transfer belt unit will be hot. Wait about 5 minutes for the machine to cool.
35
REPLACING SUPPLIES AND MAINTENANCE
Open the front cover and remove the toner collection container.
Replacing the toner collection container (page 19)
2
Do not point the holes down as used toner will spill out.
Securely close the bypass tray and then open the right cover.
3
Turn the lock levers in the direction of an arrow below and release the primary transfer belt unit.
4
36
REPLACING SUPPLIES AND MAINTENANCE
Slowly pull out the primary transfer belt unit.
(1) Grasp the primary transfer unit as shown below and slowly pull it out.
Transfer belt
Fall prevention lock
Handle
5
(2) Hold down the fall prevention lock with one hand, grasp the handle with your other hand, and remove the primary transfer belt unit.
Grip the frame of the primary transfer belt unit with your left hand and hold down the fall prevention lock on the left side with your left thumb. · When removing the fusing unit, remove slowly taking care that your hands do not contact the inside of the right cover
47
REPLACING SUPPLIES AND MAINTENANCE
Grasp the left and right levers on the fusing unit, align the unit with the installation guides, and slowly insert the fusing unit into the machine.
The fusing unit will lock into place.
5
· Always hold the fusing unit with both hands. · When holding the fusing unit, do not grasp any parts other than the left and right levers. · Do not tilt or turn over the fusing unit. · Do not open the shutter on the fusing unit. (Do not touch the heat roller inside the unit. )
Return the left and right levers to their original positions.
6
48
REPLACING SUPPLIES AND MAINTENANCE
Close the right cover.
7
Take care that your fingers are not pinched when closing the cover.
Turn on the power.
Switch the main power switch "ON" and press the [POWER] key ( ) on the operation panel to turn on the operation panel power. When replacement is finished, colour balance adjustments begin automatically. Colour balance adjustments (page 31)
8
49
REPLACING SUPPLIES AND MAINTENANCE
Replacing the ozone filter
Replace the ozone filter when you replace the fusing unit. A new ozone filter is included in the fusing unit box.
Slide the cover on the right side of the machine toward the inside to remove it.
1
Remove the ozone filter.
2
Install a new ozone filter.
3
50
REPLACING SUPPLIES AND MAINTENANCE
Attach the cover.
4
51
REPLACING SUPPLIES AND MAINTENANCE
Replacing the staple cartridge in the finisher
When the staple cartridge runs out of staples, a message will appear in the operation panel. Follow the procedure below to replace the staple cartridge.
Open the cover.
1
While pressing the lever over to the left, slide the finisher to the left until it stops.
Gently slide the finisher until it stops
2
Lower the staple case release lever and remove the staple case.
Pull the staple case out to the right.
3
52
REPLACING SUPPLIES AND MAINTENANCE
Remove the empty staple cartridge from the staple case.
Gently grasp the right side of the staple cartridge as shown and lift to the left and up. After the lock releases, continue lifting the staple cartridge to the left and up to remove it.
4
· Even when a message appears in the operation panel, staples may occasionally remain in the staple cartridge. · If staples remain, the lock will not release easily. [. . . ] · Sharp OSA is a trademark of Sharp Corporation. · RealVNC is a trademark of RealVNC Limited. · All other trademarks and copyrights are the property of their respective owners. Candid and Taffy are trademarks of Monotype Imaging, Inc. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP XGXV2E
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP XGXV2E will begin.