User manual SHURE BETA 181

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SHURE BETA 181. We hope that this SHURE BETA 181 user guide will be useful to you.

Lastmanuals help download the user guide SHURE BETA 181.


Mode d'emploi SHURE BETA 181
Download

You may also download the following manuals related to this product:

   SHURE BETA 181 DATASHEET (1250 ko)

Manual abstract: user guide SHURE BETA 181

Detailed instructions for use are in the User's Guide.

[. . . ] Featuring interchangeable cardioid, supercardioid, omnidirectional and bidirectional capsules for superior versatility, the small diaphragm of the Beta 181 provides superior audio with consistent, "textbook" polar responses in a form factor small enough to get close to the source in the tightest conditions. · When using directional microphones, work closely to the microphone for extra bass response to take advantage of Proximity Effect. · Avoid excessive handling to minimize pickup of mechanical noise and vibration. [. . . ] · Do not cover any part of the microphone grille, as this will adversely affect microphone performance. · Add a windscreen when using the microphone outdoors. The following table lists the most common applications and placement techniques. Keep in mind that microphone technique is largely a matter of personal taste; there is no one "correct" microphone position. Cardioid · Drum overheads · Piano · Acoustic instruments Supercardioid · Close-miking in performance settings · Snare drum · Acoustic instruments Omnidirectional · Room and ambient pickup · Mono drum overhead Bidirectional* · Use a pair of Beta 181/BI for Blumlein stereo teqhnique · Place microphones as far as possible from reflective surfaces to reduce Comb Filtering. · Follow the 3 to 1 Rule by spacing each microphone by at least three times the distance to its source to reduce Phase Cancellation. · Use the fewest amount of microphones as practical to increase the Potential Acoustic Gain and prevent feedback. · Aim the microphone toward the desired sound source; angle unwanted sounds toward its null point. Variations Beta 181/C Cardioid Microphone Beta 181/O Omnidirectional Microphone Beta 181/BI Bidirectional Microphone Beta 181/S Supercardioid Microphone Features · Premier live performance microphone with Shure quality, ruggedness, and reliability · Compact preamp attaches to four interchangeable capsules · Pair with a Beta 181/ BI for M/S stereo technique · String ensembles · Mono drum overhead · Dual sound sources, such as between tom-toms or acoustic instruments · Wide dynamic range for use in high SPL environments · Side-address form allows for discreet positioning in tight performance and recording settings · Innnovative locking ring provides a secure connection between capsule and preamp *Note: As with all bidirectional microphones, sounds picked up from the back will be out of polarity with the source. You must use a balanced microphone cable: XLR-to-XLR or XLR-to-TRS. Optional Accessories Cardioid Capsule Supercardioid Capsule Bidirectional Capsule Omnidirectional Capsule Beta 181 Preamp Universal Microphone Mount 7. 6 m (25 ft. ) Cable RPM181/C RPM181/S RPM181/BI RPM181/O RPM181/PRE A75M C25E SPECIFICATIONS Cartridge Type Polar Pattern Electret Condenser 181/C: 181/S: 181/O: 181/BI: 20 to 20, 000 Hz 110 Cardioid: Supercardioid: Omnidirectional: Bidirectional: 2500 load: ­46. 5 dBV/Pa[1] (2. 4 mV) ­49. 5 dBV/Pa[1] (2. 5 mV) ­52. 0 dBV/Pa[1] (2. 6 mV) ­51. 0 dBV/Pa[1] (2. 6 mV) Cardioid: Supercardioid: Omnidirectional: Bidirectional: Cardioid: Supercardioid: Omnidirectional: Bidirectional: 73. 5 dB 71. 5 dB 70. 5 dB 71. 0 dB Cardioid: Supercardioid: Omnidirectional: Bidirectional: Cardioid: Supercardioid: Omnidirectional: Bidirectional: 10. 5 dBV 7. 5 dBV 20. 5 dB SPL-A 22. 5 dB SPL-A 23. 5 dB SPL-A 23. 0 dB SPL-A 131. 0 dB 132. 0 dB 133. 5 dB 133. 0 dB 128. 5 dB 129. 5 dB 130. 5 dB 130. 5 dB 151. 5 dB SPL 154. 5 dB SPL 157. 0 dB SPL 156. 0 dB SPL 149. 0 dB SPL 152. 0 dB SPL 154. 0 dB SPL 153. 5 dB SPL Cardioid Supercardioid Omnidirectional Bidirectional CERTIFICATION Frequency Response Output Impedance Sensitivity open circuit voltage, @ 1 kHz, typical Maximum SPL 1 kHz at 1% THD[2] Eligible to bear CE Marking. Conforms to European EMC Directive 2004/108/ EC. Meets Harmonized Standards EN55103-1:1996 and EN55103-2:1996, for residential (E1) and light industrial (E2) environments. The Declaration of Conformity can be obtained from: Authorized European representative: Shure Europe GmbH Headquarters Europe, Middle East & Africa Department: EMEA Approval Wannenacker Str. 28 D-74078 Heilbronn, Germany Phone: +49 7131 72 14 0 Fax: +49 7131 72 14 14 Email: EMEAsupport@shure. de Note: Information in this guide is subject to change without notice. [. . . ] 28 D-74078 Heilbronn, Germany Phone: +49 7131 72 14 0 Fax: +49 7131 72 14 14 Email: EMEAsupport@shure. de Note: Information in this guide is subject to change without notice. For the additional information about this product, please visit www. shure. com. 1000 load: Signal-to-Noise Ratio[3] Dynamic Range Cardioid: Supercardioid: Omnidirectional: Bidirectional: 2500 load: 124, 46 mm (4. 90 in. ) 20, 32 mm (0. 80 in. ) 34, 54 mm (1. 36 in. ) 1000 load: Clipping Level @ 1 kHz, 1% THD Self Noise equivalent SPL, A-weighted, typical Common Mode Rejection 20 to 20, 000 kHz Polarity Power Requirements Net Weight [1] 2500load: 1000load: Cardioid: Supercardioid: Omnidirectional: Bidirectional: 55dB Positive pressure on diaphragm produces positive voltage on pin 2 with respect to pin 3 11­52 V DC[4] phantom power (IEC-61938) 2. 4 mA, maximum 145 g (5. 1 oz. ) 1 Pa=94 dB SPL [2] THD of microphone preamplifier when applied input signal level is equivalent to cartridge output at specified SPL [3] S/N ratio is the difference between 94 dB SPL and equivalent SPL of self noise, A-weighted [4] All specifications measured with a 48 Vdc phantom power supply. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHURE BETA 181

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SHURE BETA 181 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag