Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SIEMENS CI24RP00. We hope that this SIEMENS CI24RP00 user guide will be useful to you.
Lastmanuals help download the user guide SIEMENS CI24RP00.
You may also download the following manuals related to this product:
SIEMENS CI24RP00 annexe 1 (2857 ko)
Manual abstract: user guide SIEMENS CI24RP00
Detailed instructions for use are in the User's Guide.
[. . . ] fåëí~ää~íáçå=áåëíêìÅíáçåë
Éå
`fOQomKK `fPMomKK cfNUkmKK cfOQamKK `fOQtmKK
Table of Contents
Important Information . Stand alone appliance with dividing wall . As an end section to a row of kitchen units . .
3 4
4 4 4 4
Mounting Instructions . [. . . ] Take the supplied accessories from the protective parts of the packaging.
!
D
Warning!
Only remove the transporting securing units with which the slide in bases and the storage compartments in the appliance are protected after completing the installation as otherwise, parts could be damaged.
D
Check the appliance for damage. Do not install the appliance if there is visible damage. If there are queries, please contact the dealer.
17
5.
!
Exchanging the door stops
Warning!
D
Unscrew the door.
Before carrying out any work to the door hinges, release the spring pressure - risk of injury!Depending on the requirements of the assembly location the door stop can be exchanged to the other side. If exchanging a door stop is not necessary, proceed to the next step. Note: The door stop cannot be exchanged in the case of freezers with ice and water dispensers.
D
Remove the hinges.
D
Release the spring pressure on the hinge. In addition, set the screw from I to 0.
D
Remove parts of the ventilation grille. A ventilation grille is enclosed with the appliance for the changed door stop position. In further mounting the appliance, use this part.
D
Remove the hinge covering.
D
Swap the hinge angle to the other side.
18
D D D
Screw the door to the hinges.
Fit in the plastic part of the new ventilation grille. Mount the new ventilation grille.
D
Tighten the screw. In addition, set the screw from I to 0.
D
Attach the hinges to the appliance.
D
Exchange the hinges crosswise!
D
Attach the hinge covers.
19
6.
Note:
Preparing the installation niche
Subsurface wooden floors The wood screws (5 x 60 mm and 4 x 15 mm) which are supplied should be used for wooden floors.
D
For each appliance, two anti tilt ribs are needed. In the case of a side by side combination, a total of two anti tilt ribs are used.
D
Drilling guide holes: 3 mm for the wood screws (5 x 60 mm) 2 mm for the wood screws (4 x 15 mm) Ensure that the screws 5 x 60 at least take a hold (19 mm) in the solid subsurface.
Determine the fastening points of the anti tilt ribs. Determine the actual dimensions according to the section Installation Dimensions".
!
D
Caution!
Tightly screw the anti tilt ribs. Re examine to make sure that the screws are firmly tightened!
Ensure that in the wall area there are no electrical wires or pipes which could be damaged by pipes. Risk of injury or damage!
D
If a installation niche is deeper than the appliance, lay a strong wooden plank behind the anti tilt ribs and screw tightly to the subsurface or the wall. The length of the plank should correspond to the width of the installation niche!Subsurface concrete
!
Important note: As far as possible, always screw the wooden plank to the rear wall of the niche. In the case of some fitted shapes, it may be necessary to screw in at an angle the wood screws used to fasten the anti tilt ribs to the rear wall. Important information for securing against tilting: The set supplied, contains fastening screws for various subsurfaces. Select the fastening screws corresponding to the local conditions. If it is not possible to securely fasten the anti tilt ribs and consequently, not possible to securely fasten the appliance using the fastening screws supplied, select another suitable method for securely fastening the anti tilt ribs.
Warning!
When installing or working with floor anchors, always wear protective glasses or other protective equipment / clothing. Floor anchors are not suitable for use in connection with lightweight construction masonry, breeze blocks or tiles. [. . . ] Shorten the finger protection using a steel rule and a knife to the required length.
D
33
25. Attaching the covers
D
Screw the fastening angle below the lower hinge. Push open the covering flap.
D
Attach the cover ribs on both longitudinal sides of the door.
D
Push open the covering bar on the finger protection.
Note: The covering bar for the finger protection is the bar with the short side.
D
Attach the light switch cover. The light switch cover for the 61. 0 cm / 24" and 76. 0 cm / 30" width can be screwed to the door.
34
Only in the case of a side by side set up of two appliances:
D D
Attach the cover ribs to the fastening plates and the angles (laterally).
Insert the cover rib in the crack between the appliances.
Only in the case of individual appliances:
26. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SIEMENS CI24RP00
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SIEMENS CI24RP00 will begin.