Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SIEMENS GIGASET M101 DATA. We hope that this SIEMENS GIGASET M101 DATA user guide will be useful to you.
Lastmanuals help download the user guide SIEMENS GIGASET M101 DATA.
Manual abstract: user guide SIEMENS GIGASET M101 DATA
Detailed instructions for use are in the User's Guide.
[. . . ] EN
Dear Customer, Gigaset Communications GmbH is the legal successor to Siemens Home and Office Communication Devices GmbH & Co. KG (SHC), which in turn continued the Gigaset business of Siemens AG. Any statements made by Siemens AG or SHC that are found in the user guides should therefore be understood as statements of Gigaset Communications GmbH. Sehr geehrte Kundin, sehr geehrter Kunde, die Gigaset Communications GmbH ist Rechtsnachfolgerin der Siemens Home and Office Communication Devices GmbH & Co. [. . . ] The configuration program offers a dialog box entitled Properties of Gigaset M101 Data which contains the four tabs Connection, Operating mode, Local adapter and Remote adapter.
A number of special fields are also provided for special inputs.
A Back
18
û
"Connection" tab
Upper section: connecting to the PC
Configuration program options
You can set the PC COM port at which the local adapter is connected in the upper section of the tab.
We recommend leaving the option No automatic detection at program start-up deactivated (as shown). The program then checks the existing COM ports and determines where the adapter is connected. Manual interface selection is only recommended if there is more than one Gigaset M101 Data unit connected to the PC. As soon as the program finds an adapter or identifies the manually selected interface, it sends it the configuration command via the control lines. This action switches the adapter to configuration status. This is indicated by the Status display in the dialog box. Gigaset M101 Data can only be configured under these conditions. Your Gigaset M101 Data will automatically switch the adapter back to operating status at the end of the program. Lower section: DECT connection This section indicates whether a radio connection exists and if so, to which remote adapter. It also indicates the quality of the connection. A remote adapter must be registered before it can be selected here.
A Back
19
û
"Operating mode" tab
Important:
Configuration program options
If one of the adapters is set to "AT commands (PC)" or "AVM compatible (PC)", the other adapter must switch to the corresponding operating mode "AT commands (device)" or "AVM compatible (device)". If one adapter is switched to "Direct connection", the other adapter must also be switched to this mode. The appropriate switches are performed automatically if you select an operating mode for a Gigaset M101 Data unit. Setting the operating mode Open the Operating mode tab and select one of the five modes:
The three connection types are used for different purposes: Direct connection The permanent transmission parameters for the PC's COM port are manually set at the computer without automatic baud rate or data format recognition. This is always useful if the device at the remote adapter does not support baud rate or data format recognition as performed by conventional modems, e. g. AT commands (PC)# Î page 9 AT commands (device)# Î page 9 AVM compatible (PC)# Î page 9 AVM compatible (device) Automatic recognition of the transmission parameters based on the data from the PC at the local adapter. Automatic emulation of the transmission parameters based on the values received from the PC at the remote adapter. Automatic recognition of the transmission parameters in AVM-compatible format based on the data from the PC at the local adapter. Automatic emulation of the transmission parameters in AVM-compatible format on the basis values received from the PC at the remote adapter.
A Back
20
û
Special settings for "Direct connection" mode
Configuration program options
In Direct connection mode, the fields in the lower section of the dialog box are activated: you can set the transmission parameters for the COM port at the PC. Use the default settings if you do not want to change any other parameters. In the event of malfunctions, reduce the speed in the Bits per second field. Set your communication software likewise to this value. [. . . ] Commands that are not compatible with Hayes are transferred with the connection. Set Gigaset M101 Data to direct connection 115000 bps, See "PC-PC direct cable connection: via RS232/V. 24 interface" on page 34 During installation, WinFax 8. 0 requires a modem driver for voice functions. The Generic driver /Rockwell Fax/voice driver is to be used here according to ELSA AG.
Faxes are distorted when sent Incorrect driver set for voice with ELSA Microlink 56k and functions under WinFax 8. 0. WinFax 8. 0 software.
A Back
47
û
Miscellaneous Fault Cause
What happens if. . .
Solution
Monitor fault when Gigaset DECT HF wanted signals is in- Move Gigaset M101 Data M101 Data is active (e. g. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SIEMENS GIGASET M101 DATA
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SIEMENS GIGASET M101 DATA will begin.