User manual SIEMENS MICROMASTER 440

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SIEMENS MICROMASTER 440. We hope that this SIEMENS MICROMASTER 440 user guide will be useful to you.

Lastmanuals help download the user guide SIEMENS MICROMASTER 440.


Mode d'emploi SIEMENS MICROMASTER 440
Download
Manual abstract: user guide SIEMENS MICROMASTER 440

Detailed instructions for use are in the User's Guide.

[. . . ] MICROMASTER 440 Operating instructions Issue A1 User Documentation MICROMASTER 440 DOCUMENTATION Getting Started Guide Is for quick commissioning with SDP and BOP. Operating Instructions Gives information about features of the MM440, Installation, Commissioning, Control modes, System Parameter structure, Troubleshooting, Specifications and available options of the MM440. Parameter List The Parameter List contains the description of all Parameters structured in functional order and a detailed description. The Parameter list also includes a series of function plans. Reference Manual The Reference Manual gives detailed information about engineering communication troubleshooting and maintenance. Catalogues In the catalogue you will find all the necessary information to select an appropriate inverter, as well as filters, chokes, operator panels and communication options. Overview 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L Installation Commissioning MICROMASTER 440 Using the MICROMASTER 440 System Parameters Operating instructions User Documentation Troubleshooting MICROMASTER 440 Specifications Available options Electro-Magnetic Compatibility Appendices Valid for Converter Type MICROMASTER 440 Control Version 04. 2001 Index Issue A1 IMPORTANT NOTICE Not all inverters currently have UL approval. UL listing can be determined by examining the inverter's Rating Label. For UL listed products the following UL mark is used: Further information can be obtained from Internet website: http://www. siemens. de/micromaster Approved Siemens Quality for Software and Training is to DIN ISO 9001, Reg. 2160-01 The reproduction, transmission or use of this document, or its contents is not permitted unless authorized in writing. [. . . ] 49 Faults and warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 MICROMASTER 440 Operating instructions 6SE6400-5CA00-0BP0 45 4 Using the MICROMASTER 440 International English Warnings When operating electrical devices, it is impossible to avoid applying hazardous voltages to certain parts of the equipment. Emergency Stop facilities according to EN 60204 IEC 204 (VDE 0113) must remain operative in all operating modes of the control equipment. Any disengagement of the Emergency Stop facility must not lead to uncontrolled or undefined restart. Wherever faults occurring in the control equipment can lead to substantial material damage or even grievous bodily injury (i. e. potentially dangerous faults), additional external precautions must be taken or facilities provided to ensure or enforce safe operation, even when a fault occurs (e. g. independent limit switches, mechanical interlocks, etc. ). Certain parameter settings may cause the inverter to restart automatically after an input power failure. Motor parameters must be accurately configured for motor overload protection to operate correctly. This equipment is capable of providing internal motor overload protection in 2 accordance with UL508C section 42. Refer to P0610 (level 3) and P0335, I t is ON by default. Motor overload protection can also be provided using an external PTC (disabled by default P0601). This equipment is suitable for use in a circuit capable of delivering not more than 10, 000 symmetrical amperes (rms), for a maximum voltage of 230V/460V/575V when protected by a H or K type fuse (see Tables starting on page 77) This equipment must not be used as an `emergency stop mechanism' (see EN 60204, 9. 2. 5. 4) 4. 1 Frequency Setpoint (P1000) Default: Terminal 3/4 (AIN+/ AIN -, 0. . . 10 V corresponds to 0. . . 50/60 Hz) Other settings: see P1000 Notes For USS see Reference Manual, for PROFIBUS see Reference Manual and PROFIBUS Instructions. MICROMASTER 440 46 Operating instructions 6SE6400-5CA00-0BP0 International English 4 Using the MICROMASTER 440 4. 2 Command Sources (P0700) Notes The ramp times and ramp-smoothing functions also affect how the motor starts and stops. For details of these functions, please refer to parameters P1120, P1121, P1130 ­ P1134 in the Parameter List. Starting the motor Default: Other settings: Terminal 5 (DIN 1, high) see P0700 to P0708 Stopping the motor There are several ways to stop the motor: Default: OFF1 OFF2 Terminal 5 (DIN 1, low) Off button on BOP/AOP, pressing the Off button once long (two seconds) or twice (with default settings not possible without BOP/AOP) OFF3 no standard setting Other settings: see P0700 to P0708 Reversing the motor Default: Other settings: Terminal 6 (DIN 2, high) see P0700 to P0708 4. 3 4. 3. 1 OFF and braking Functions OFF1 This command (produced by canceling the ON command) causes the inverter to come to a standstill at the selected ramp-down rate. Parameter to change ramp-down time see P1121 Notes ON and the following OFF1 command must have the same source. If the ON/OFF1 command is set to more than one digital input, only the last set digital input is valid e. g. OFF1 can be combined with DC braking, Compound braking or dynamic braking. MICROMASTER 440 Operating instructions 6SE6400-5CA00-0BP0 47 4 Using the MICROMASTER 440 International English 4. 3. 2 OFF2 This command causes the motor to coast to a standstill (pulses disabled). Note The OFF2 command can have one or more sources. By default the OFF2 command is set to BOP/AOP. This source still exists even if other sources are defined by one of the following parameters, P0700 to P0708 inclusive. 4. 3. 3 OFF3 An OFF3 command causes the motor to decelerate rapidly. For starting the motor when OFF3 is set, the binary input has to be closed (high). If OFF3 is high, the motor can be started and stopped by OFF1 or OFF2. [. . . ] All MICROMASTER units are certified for compliance with the EMC directive, when installed in accordance with the recommendations in Section 2. MICROMASTER 440 92 Operating instructions 6SE6400-5CA00-0BP0 International English 9 Electro-Magnetic Compatibility (EMC) 9. 1. 4 EMC Directive Compliance with Imminent Harmonics Regulations From 1st January 2001 all electrical apparatus covered by the EMC Directive will have to comply with EN 61000-3-2 "Limits for harmonic current emissions (equipment input <= 16A per phase)". All Siemens variable speed drives of the MICROMASTER, MIDIMASTER, MICROMASTER Eco and COMBIMASTER ranges, which are classified as "Professional Equipment" within the terms of the standard, fulfill the requirements of the standard. Special considerations for 250W to 550W drives with 230V 1ac mains supplies when used in non-industrial applications Units in this voltage and power range will be supplied with the following warning: "This equipment requires supply authority acceptance for connection to the public supply network". Please refer to EN 61000-3-12 sections 5. 3 and 6. 4 for further information. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SIEMENS MICROMASTER 440

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SIEMENS MICROMASTER 440 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag