User manual SILENT KNIGHT SK-6324

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SILENT KNIGHT SK-6324. We hope that this SILENT KNIGHT SK-6324 user guide will be useful to you.

Lastmanuals help download the user guide SILENT KNIGHT SK-6324.


Mode d'emploi SILENT KNIGHT SK-6324
Download
Manual abstract: user guide SILENT KNIGHT SK-6324

Detailed instructions for use are in the User's Guide.

[. . . ] SK-6324 Basic Operating Instructions P/N 151119 Rev. A These instructions must be framed and displayed next to the SK-6324 panel in accordance with NFPA 72 fire code for Local Fire Alarm Systems. LED (Color) AC POWER (green) Function ON = Good AC OFF = Low AC trouble condition and it was acknowledged FLASHING = Unacknowledged AC Low trouble condition ON = System trouble OFF = System OK FLASHING = At least one serial device is in trouble DOUBLE FLASHING = Two types of serial devices are in trouble. [. . . ] If flashing, press the ACK button to acknowledge the condition. SYSTEM SILENCED (yellow) ON = System audible output has been silenced OFF = Nothing silenced FLASHING = Partially silenced ON = Ground fault condition exists and was acknowledged OFF = No fault FLASHING = A ground fault condition detected ON = Battery low condition that has been acknowledged OFF = Good battery condition FLASHING = Battery low condition ON = Zone in alarm which has been acknowledged OFF = No Alarm FLASHING = Zone in alarm has not yet been acknowledged ON = Zone has a supervisory condition which has been acknowledged (selfrestoring condition) OFF = No supervisory condition exists FLASHING = Supervisory trouble detected on that zone that has not yet been acknowledged GROUND FAULT (yellow) LOW BATTERY (yellow) If flashing, press the ACK button to acknowledge the condition. ZONE 1 Through ZONE 6 ALARM (red) If flashing, press the ACK button to acknowledge the condition. Cut Along the Dotted Line SUPERVISORY (yellow) If flashing, press the ACK button to acknowledge the condition. TROUBLE (yellow) ON = Zone has a trouble condition which has been acknowledged OFF = No zone trouble FLASHING = Zone has a trouble condition not yet acknowledged DOUBLE FLASHING = Zone was disabled CLEAN ME FLASHING = Indicates that the smoke detector needs cleaning If flashing, press the ACK button to acknowledge the condition. A "Clean Me Flash" is a flash with a long LED "on" Time and a short LED "off" time indicating that the smoke detector needs cleaning. Applies only to smoke detectors with the CLEAN ME feature. The "Clean Me" flash starts after the trouble condition has been acknowledge. NAC 1 Through NAC 3 ACTIVE (yellow) ON = NAC is active during an alarm OFF = NAC is not active during alarm If flashing, press the ACK button to acknowledge the condition. TROUBLE (yellow) ON = NAC has a trouble condition and was acknowledged OFF = No trouble condition FLASHING = NAC is in trouble DOUBLE FLASHING = Circuit was disabled Operation Disable notification appliance circuit. To re-enable the circuit, press [NAC DISABLE] again. Disable a zone To re-enable the circuit, press [ZONE DISABLE] again. Begin Walk Test End Walk Test (The test ends automatically after 10 minutes of no system activity. ) Acknowledge condition (alarm, supervisory, trouble) Silence Panel Perform system reset To send a DACT test to your central station. To reset the DACT. Keystrokes Press the appropriate [NAC DISABLE] key. The NAC circuit will be disabled and the corresponding TROUBLE LED will Double Flash. This function is not available during an alarm condition. Press the appropriate [ZONE DISABLE] key. The zone will be disabled and the corresponding TROUBLE LED will Double Flash. This function is not available during an alarm or supervisory condition. [. . . ] Resets alarms, supervisories, troubles and all LEDs. Press the [DIALER RESET] button. For Service Contact: [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SILENT KNIGHT SK-6324

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SILENT KNIGHT SK-6324 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag